Main Field

Calibration Laboratories

Valid Since:Aug 17 , 2023

Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Balance & Scale
  • Top loading weighing scale
Active
Pressure
  • Vacuum (Digital gauges ,Analogue gauges , Transmitters , Transducers )
  • Comparison method using MCL-QSD-CP-P-001 based upon DKD-R6-1 : 2014 using Crystal pressure calibrator .
  • -100 kPa to 0 kPa
0.6 kPa(Laboratory Premises & Customer Permises)Active
  • Pneumatic (Digital gauges, Analogue gauges , Transmitters , Transducers )
  • Comparison method using MCL-QSD-CP-P-001 based upon DKD-R6-1 : 2014 using Crystal pressure calibrator .
  • 0 to 100 kPa
0.1 kPa(Laboratory Premises & Customer Permises)Active
  • Comparison method using MCL-QSD-CP-P-001 based upon DKD-R6-1 : 2014 using Crystal pressure calibrator Crystal .
  • >0.1 MPa to 14 MPa
1.4 kPa(Laboratory Premises & Customer Permises)Active
  • Hydraulic (Digital gauges, Analogue gauges , Transmitters , Transducers )
  • Comparison method using MCL-QSD-CP-P-001 based upon DKD-R6-1 : 2014 using Crystal pressure calibrator .
  • 0.1 MPa to 14 MPa
10 kPa(Laboratory Premises & Customer Permises)Active
  • Hydraulic (Digital gauges, Analogue gauges , Transmitters , Transducers , Differential Pressure etc.)
  • Comparison method using MCL- QSD-CP-P-001 based upon DKD- R6-1 : 2014 using Crystal pressure calibrator and Vijay Calibrator .
  • 0 to 100 MPa
10 kPa(Laboratory Premises & Customer Permises)Active
Torque
  • TORQUE / Torque Wrench / Torque Screw Driver/Hand Torque Tool / Torque Spanner (Type-I & II All Classes)
  • METHOD -Comparsion CRM USED - Torque Tranducer REFERANCE STANDARD.- ISO 6789-1 , ISO 6789-2 INTERNAL PROCEDURE NUMBER - MCL-QSD-CP-TQ-001
  • 0.2 N-m to 2 N-m
0.8 %LaboratoryActive
  • 2 N-m to 20 N-m
0.8 %LaboratoryActive
  • 20 N-m to 200 N-m
0.8 %LaboratoryActive
  • 200 N-m to 2000 N-m
0.8 %LaboratoryActive
Temperature & Humidity
  • Resistance Temperature Sensor with Display Unit
  • METHOD: Comparison with a reference RTD & R-Type thermocouple with indicator REFERENCE STANDARD: DKD-R-5-1 INTERNAL PROCEDURE: MCL-QSD-CP-T-001
  • -80 °C to 250 °C
0.6 °CLaboratory PremisesActive
  • 250 °C to 600 °C
4 °CLaboratory PremisesActive
  • 600 °C to 850°C
5 °CLaboratory PremisesActive
  • Thermocouple with display unit (Base Metal / Noble Metal )
  • METHOD: Comparison with a reference RTD & R-Type thermocouple with indicator REFERENCE STANDARD: Euramet cg-8 INTERNAL PROCEDURE: MCL-QSD-CP-T-001
  • -80 °C to Ambient
1 °CLaboratory PremisesActive
  • Ambient to 250 °C
2 °CLaboratory PremisesActive
  • 250 °C to 650 °C
5 °CLaboratory PremisesActive
  • 650 °C to 1200 °C
7 °CLaboratory PremisesActive
  • Resistance Temperature Sensor without display unit
  • METHOD: Comparison with a reference RTD &R-Type thermocouple with indicator REFERENCE STANDARD: DKD-R-5-1 INTERNAL PROCEDURE: MCL-QSD-CP-T-002
  • -80 °C to 250 °C
0.6°CLaboratory PremisesActive
  • 250 °C to 600 °C
4 °CLaboratory PremisesActive
  • 600 °C to 850°C
5 °CLaboratory PremisesActive
  • Platinum Resistance Thermometer with or without display unit
  • METHOD: Use of Ice Bath REFERENCE STANDARD: DKD-R-5-1 INTERNAL PROCEDURE: MCL-QSD-CP-T-001 and MCL-QSD-CP-T-002
  • 0 °C
0.1 °CLaboratory PremisesActive
  • Thermocouple without display unit (Base Metal / Noble Metal )
  • METHOD: Comparison with a reference RTD &R-Type thermocouple with indicator REFERENCE STANDARD: Euramet cg-8 INTERNAL PROCEDURE: MCL-QSD-CP-T-002
  • -80 °C to Ambient
1 °CLaboratory PremisesActive
  • Ambient to 250 °C
2 °CLaboratory PremisesActive
  • 250 °C to 650 °C
5 °CLaboratory PremisesActive
  • 650 °C to 1200 °C
7 °CLaboratory PremisesActive
  • Dry Block Calibrators
  • METHOD: Comparison with a reference RTD &R-Type thermocouple with indicator REFERENCE STANDARD: Euramet cg-13 INTERNAL PROCEDURE: MCL-QSD-CP-T-006
  • .-90°C to Ambient
0.6 °CLaboratory Premises and Customer permisesActive
  • Ambient to 1200 °C
4 °CLaboratory Premises and Customer permisesActive
  • Liquid Bath
  • METHOD: Comparison with a reference RTD INTERNAL PROCEDURE: MCL-QSD-CP-T-006
  • .-90 °C to 250 °C
0.4°CLaboratory Premises and Customer permisesActive
  • Environmnetal Chamber / Climatic Chamber / Temperature and Humidity Chambers (Single & Nine Point)
  • METHOD: Comparison with RTD (Class A) with indicator, and RH Probe REFERENCE STANDARD.-DKD-R5-7 OR EURAMET GUIDELINE NO: 20 INTERNAL PROCEDURE NUMBER - MCL-QSD-CP-T-004 & MCL-QSD-CP-T-009
  • 10 °C to 60 °C
1.2 °CCustomer PremisesActive
  • 20 % rh to 95 % rh (Single Point at Center)
7 %rhCustomer PremisesActive
  • Dry Oven, Freezer, Chiller, Refrigerator, Furnace, Hot Cabinet (Single Point )
  • METHOD: Comparison with a RTD (Class A) with indicator REFERENCE STANDARD: DKD-R5-7, EURAMET GUIDELINE NO: 20 INTERNAL PROCEDURE: MCL-QSD-CP-T-003
  • .-90 °C to 400 °C
1.5 °CLaboratory Premises and Customer permisesActive
  • 400 °C to 1200 °C
5 °CLaboratory Premises and Customer permisesActive
  • Dry Oven, Freezer, Chiller, Refrigerator, Furnace, Hot Cabinet (9 Point )
  • METHOD: Comparison with 9 RTD's (Class A) with indicator REFERENCE STANDARD: DKD-R5-7, EURAMET GUIDELINE NO: 20 INTERNAL PROCEDURE: MCL-QSD-CP-T-004
  • -30 °C to 400 °C
2 °CLaboratory Premises and Customer permisesActive
  • Autoclave (Single Point )
  • METHOD: Comparison with a RTD (Class A) with indicator INTERNAL PROCEDURE: MCL-QSD-CP-T-003
  • 110 °C to 140 °C
1 °CLaboratory Premises and Customer permisesActive
  • Autoclave (5 Point )
  • METHOD: Comparison with 5 RTD's (Class A) with indicator INTERNAL PROCEDURE: MCL-QSD-CP-T-004
1.2 °CLaboratory Premises and Customer permisesActive
  • Air Temperature and Relative Humidity Meter
  • METHOD: Comparison with a RTD (Class A) with indicator and RH reference probe in a Humidity Chamber INTERNAL PROCEDURE: MCL-QSD-CP-T-009
  • 10 °C to 45 °C
0.6°CLaboratory PremisesActive
  • 10 % rh to 95 % rh
4 %rhLaboratory PremisesActive
  • Liquid in Glass Thermometer
  • METHOD: Comparison with a RTD (Class A) with indicator REFERENCE STANDARD: OIML R 133 INTERNAL PROCEDURE: MCL-QSD-CP-T-008
  • -10°C to Ambient
0.6°CLaboratory PremisesActive
  • Ambient to 250°C
1 °CLaboratory PremisesActive
  • Temperature Gauge, Temperature Datalogger with Sensor (Paper, Paperless), Pen Type Thermometer
  • METHOD: Comparison with a reference RTD &R-Type thermocouple with indicator INTERNAL PROCEDURE: MCL-QSD-CP-T-001
  • -80 °C to Ambient
1 °CLaboratory PremisesActive
  • Ambient to 250 °C
3 °CLaboratory PremisesActive
  • 250 °C to 650 °C
5 °CLaboratory PremisesActive
  • 650 °C to 1200 °C
7 °CLaboratory PremisesActive
  • Temperature Measuring Devices - Transmitter, Transducer, switch, Controller with Sensor's
  • METHOD: Comparison with a reference RTD & R-Type thermocouple with indicator INTERNAL PROCEDURE: MCL-QSD-CP-T-010
  • -80 °C to Ambient
1 °CLaboratory PremisesActive
  • Ambient to 250 °C
3 °CLaboratory PremisesActive
  • 250 °C to 650 °C
5 °CLaboratory PremisesActive
  • 650 °C to 1200 °C
7 °CLaboratory PremisesActive
  • IR Thermometer
  • METHOD: Comparison with an IR thermometer using a Black Body Source REFERENCE STANDARD: ASTM-E2847-14 INTERNAL PROCEDURE: MCL-QSD-CP-T-005
  • Ambient to 500 °C
5 °CLaboratory PremisesActive
  • METHOD: Ice Cavity as reference Black Body Source REFERENCE STANDARD: ASTM E2847-14 INTERNAL PROCEDURE: MCL-QSD-CP-T-005
  • 0 °C
1 °CLaboratory PremisesActive
Electrical-Measuring
  • DC Voltage
  • Direct Calibration using Fluke 5502A as a reference standard uisng MCL-QSD-CP-E-001 (Technical Protocol) m= measured value
  • 0 mV to 100 mV
0.006%*m+3.1 µVLaboratory Premises & Customer PremisesActive
  • > 100 mV to 1 V
0.005%*m+9.2µVLaboratory Premises & Customer PremisesActive
  • > 1 V to 10 V
0.005 % *m+64 µVLaboratory Premises & Customer PremisesActive
  • > 10 V to 100 V
0.0055%*m+0.64 mVLaboratory Premises & Customer PremisesActive
  • > 100 V to 1000 V
0.0055%*m+6.2 mVLaboratory Premises & Customer PremisesActive
  • AC Voltage (Frequency 10 Hz to 10 kHz )
  • Direct Calibration using Fluke 5502A as a reference standard uisng MCL-QSD-CP-E-001 (Technical Protocol) m= measured value
  • 1 mV to 10 mV
0.10%*m+17 µVLaboratory Premises & Customer PremisesActive
  • > 10 mV to 100 mV
0.030%*m+35 µVLaboratory Premises & Customer PremisesActive
  • > 100 mV to 1 V
0.030%*m+36 µVLaboratory Premises & Customer PremisesActive
  • > 1 V to 10 V
0.030%*m+0.62 mVLaboratory Premises & Customer PremisesActive
  • > 10 V to 100 V
0.080%*m+9.3 mVLaboratory Premises & Customer PremisesActive
  • AC Voltage (Frequency 45 Hz to 8 kHz)
  • > 100 V to 1000 V
0.090%*m+78 mVLaboratory Premises & Customer PremisesActive
  • DC Current
  • Direct Calibration using Fluke 5502A as a reference standard uisng MCL-QSD-CP-E-001 (Technical Protocol) m= measured value
  • 0 µA to 100 µA
0.015%*m+16 nALaboratory Premises & Customer PremisesActive
  • > 100 µA to 1 mA
0.013%*m+0.05 µALaboratory Premises & Customer PremisesActive
  • > 1 mA to 10 mA
0.010%*m+0.25µALaboratory Premises & Customer PremisesActive
  • Direct Calibration using Fluke 5502A as a reference standard uisng MCL-QSD-CP-E-001 (Technical Protocol) m= measured value
  • > 10 mA to 100 mA
0.010%*m+3.4 µALaboratory Premises & Customer PremisesActive
  • > 100 mA to 400 mA
0.038%*m+70 µALaboratory Premises & Customer PremisesActive
  • > 400 mA to 1 A
0.038%*m+0.070 mALaboratory Premises & Customer PremisesActive
  • > 1 A to 3 A
0.060%*m+0.43 mALaboratory Premises & Customer PremisesActive
  • > 3A to 10 A
0.060%*m+0.86 mALaboratory Premises & Customer PremisesActive
  • > 10 A to 20 A
0.060%*m+1.7 mALaboratory Premises & Customer PremisesActive
  • DC Current Clamp
  • > 20 A to 1000 A
0.26%*m+6.0 ALaboratory Premises & Customer PremisesActive
  • Resistance (2 Wire and 4 Wire )
  • Direct Calibration using Fluke 5502A as a reference standard uisng MCL-QSD-CP-E-001 (Technical Protocol) m= measured value
  • 0 Ω to 10 Ω
0.012%*m+0.091 mΩLaboratory Premises & Customer PremisesActive
  • > 10 Ω to 100 Ω
0.0090%*m+0.72mΩLaboratory Premises & Customer PremisesActive
  • > 100 Ω to 1 kΩ
0.0090%*m+70mΩLaboratory Premises & Customer PremisesActive
  • > 1kΩ to 10 kΩ
0.0090%*m+72 mΩLaboratory Premises & Customer PremisesActive
  • > 10 kΩ to 100 kΩ
0.011%*m+0.72 ΩLaboratory Premises & Customer PremisesActive
  • > 100 kΩ to 1 MΩ
0.015%*m+13 ΩLaboratory Premises & Customer PremisesActive
  • > 1 MΩ to 10 MΩ
0.060%*m+0.15 kΩLaboratory Premises & Customer PremisesActive
  • > 10 MΩ to 100 MΩ
0.50%*m+7.7 kΩLaboratory Premises & Customer PremisesActive
  • > 100 MΩ to 1000 MΩ
1.5%*m+0.39 MΩLaboratory Premises & Customer PremisesActive
  • AC Current (Frequency 10 Hz to 1 kHz)
  • Direct Calibration using Fluke 5502A as a reference standard uisng MCL-QSD-CP-E-001 (Technical Protocol) m= measured value
  • 29 µA to 100 µA
0.13 %*m+0.11 µALaboratory Premises & Customer PremisesActive
  • > 100 µA to 1 mA
0.10%*m+0.42 µALaboratory Premises & Customer PremisesActive
  • > 1 mA to 10 mA
0.040%*m+3.0 µALaboratory Premises & Customer PremisesActive
  • > 10 mA to 100 mA
0.040%*m+83µALaboratory Premises & Customer PremisesActive
  • > 100 mA to 400 mA
0.050%*m+0.26 mALaboratory Premises & Customer PremisesActive
  • > 400 mA to 1 A
0.050%*m+0.25 mALaboratory Premises & Customer PremisesActive
  • > 1 A to 3 A
0.050%*m+1.3 mALaboratory Premises & Customer PremisesActive
  • AC Current (Frequency 45 Hz to 400 Hz)
  • > 3A to 10 A
0.10%*m+3.0 mALaboratory Premises & Customer PremisesActive
  • > 10 A to 20 A
0.15%*m+6.3 mALaboratory Premises & Customer PremisesActive
  • AC Current Clamp (Frequency 45 Hz to 400 Hz)
  • > 20 A to 1000 A
0.34%*m+6.0 ALaboratory Premises & Customer PremisesActive
  • Capacitance
  • 220 pF to 399 pF
0.50%*m+7.7 pFLaboratory Premises & Customer PremisesActive
  • >399 pF to 1 nF
0.50%*m+7.7 pFLaboratory Premises & Customer PremisesActive
  • > 1 nF to 10 nF
0.25%*m+13 pFLaboratory Premises & Customer PremisesActive
  • > 10 nF to 100 nF
0.25%*m+0.12 nFLaboratory Premises & Customer PremisesActive
  • > 100 nF to 1 µF
0.25%*m+1.3 nFLaboratory Premises & Customer PremisesActive
  • > 1 µF to 10 µF
0.25%*m+13 nFLaboratory Premises & Customer PremisesActive
  • > 10 µF to 100µF
0.45%*m+0.12µFLaboratory Premises & Customer PremisesActive
  • > 100 µF to 1 mF
0.45%*m+1.7 µFLaboratory Premises & Customer PremisesActive
  • > 1 mF to 10mF
0.45%*m+17µFLaboratory Premises & Customer PremisesActive
  • Frequency
  • 0.01 Hz to 1 Hz
0.0025%*m+0.78 mHzLaboratory Premises & Customer PremisesActive
  • > 1 Hz to 10 Hz
0.0025%*m+0.78 mHzLaboratory Premises & Customer PremisesActive
  • > 10 Hz to 100 Hz
0.0025%*m+0.78 mHzLaboratory Premises & Customer PremisesActive
  • > 100 Hz to 500 Hz
0.0025%*m+0.78 mHzLaboratory Premises & Customer PremisesActive
  • > 500 Hz to 1 kHz
0.0025%*m+1.5 mHzLaboratory Premises & Customer PremisesActive
  • > 1 kHz to 10 kHz
0.0025%*m+9.2 mHzLaboratory Premises & Customer PremisesActive
  • > 10 kHz to 100 kHz
0.0025%*m+93 mHzLaboratory Premises & Customer PremisesActive
  • > 100 kHz to 1000 kHz
0.0025%*m+0.92 HzLaboratory Premises & Customer PremisesActive
  • Temperature Simulation RTD
  • Direct Calibration using Fluke 5502A as a reference standard uisng MCL-QSD-CP-E-003 (Technical Protocol)
  • -200 °C to -80 °C
0.04 °CLaboratory Premises & Customer PremisesActive
  • > -80 °C to 0 °C
0.04 °CLaboratory Premises & Customer PremisesActive
  • > 0 °C to 100 °C
0.06 °CLaboratory Premises & Customer PremisesActive
  • > 100°C to 300°C
0.07 °CLaboratory Premises & Customer PremisesActive
  • > 300 °C to 400 °C
0.08 °CLaboratory Premises & Customer PremisesActive
  • > 400 °C to 630 °C
0.09 °CLaboratory Premises & Customer PremisesActive
  • > 630 °C to 800 °C
0.18 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (K- Type Thermocouple)
  • -200 °C to -100 °C
0.28 °CLaboratory Premises & Customer PremisesActive
  • > -100 °C to -25 °C
0.18 °CLaboratory Premises & Customer PremisesActive
  • > -25 °C to 120 °C
0.16 °CLaboratory Premises & Customer PremisesActive
  • > 120°C to 1000°C
0.23 °CLaboratory Premises & Customer PremisesActive
  • > 1000 °C to 1372 °C
0.33 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (J- Type Thermocouple)
  • -210 °C to -100 °C
0.24 °CLaboratory Premises & Customer PremisesActive
  • > -100 °C to -30 °C
0.16 °CLaboratory Premises & Customer PremisesActive
  • > -30°C to 150 °C
0.15 °CLaboratory Premises & Customer PremisesActive
  • > 150°C to 760 °C
0.17 °CLaboratory Premises & Customer PremisesActive
  • > 760 °C to 1200 °C
0.21 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (N- Type Thermocouple)
  • -200 °C to -100 °C
0.34 °CLaboratory Premises & Customer PremisesActive
  • > -100 °C to -25 °C
0.20 °CLaboratory Premises & Customer PremisesActive
  • > -25 °C to 120 °C
0.18 °CLaboratory Premises & Customer PremisesActive
  • > 120°C to 410 °C
0.18 °CLaboratory Premises & Customer PremisesActive
  • > 410 °C to 1300 °C
0.24 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (R- Type Thermocouple)
  • 0 °C to 250 °C
0.49 °CLaboratory Premises & Customer PremisesActive
  • > 250 °C to 400 °C
0.32 °CLaboratory Premises & Customer PremisesActive
  • > 400 °C to 1000 °C
0.30 °CLaboratory Premises & Customer PremisesActive
  • > 1000 °C to 1767 °C
0.34 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (S- Type Thermocouple)
  • 0 °C to 250 °C
0.42 °CLaboratory Premises & Customer PremisesActive
  • > 250 °C to 1000 °C
0.33 °CLaboratory Premises & Customer PremisesActive
  • > 1000 °C to 1400 °C
0.33 °CLaboratory Premises & Customer PremisesActive
  • > 1400 °C to 1767 °C
0.39 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (B- Type Thermocouple)
  • 600°C to 800 °C
0.41 °CLaboratory Premises & Customer PremisesActive
  • > 800 °C to 1000 °C
0.33 °CLaboratory Premises & Customer PremisesActive
  • > 1000 °C to 1550 °C
0.29 °CLaboratory Premises & Customer PremisesActive
  • > 1550 °C to 1820 °C
0.30 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (C- Type Thermocouple)
  • 0 °C to 150 °C
0.27 °CLaboratory Premises & Customer PremisesActive
  • > 150 °C to 650 °C
0.24 °CLaboratory Premises & Customer PremisesActive
  • > 650 °C to 1000 °C
0.27 °CLaboratory Premises & Customer PremisesActive
  • > 1000°C to 1800 °C
0.41 °CLaboratory Premises & Customer PremisesActive
  • > 1800 °C to 2316°C
0.67°CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (E- Type Thermocouple)
  • -250 °C to -100 °C
0.40°CLaboratory Premises & Customer PremisesActive
  • > -100 °C to -25 °C
0.16°CLaboratory Premises & Customer PremisesActive
  • > -25 °C to 350 °C
0.15°CLaboratory Premises & Customer PremisesActive
  • > 350 °C to 650 °C
0.16°CLaboratory Premises & Customer PremisesActive
  • > 650 °C to 1000 °C
0.19°CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (L- Type Thermocouple)
  • -200 °C to -100 °C
0.31°CLaboratory Premises & Customer PremisesActive
  • > -100 °C to 800 °C
0.23°CLaboratory Premises & Customer PremisesActive
  • > 800 °C to 900 °C
0.17°CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (T- Type Thermocouple)
  • -250 °C to -150 °C
0.51°CLaboratory Premises & Customer PremisesActive
  • > -150 °C to 0°C
0.22°CLaboratory Premises & Customer PremisesActive
  • > 0 °C to 120°C
0.16°CLaboratory Premises & Customer PremisesActive
  • > 120 °C to 400 °C
0.15°CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (U- Type Thermocouple)
  • -200 °C to 0 °C
0.45°CLaboratory Premises & Customer PremisesActive
  • > 0 °C to 600 °C
0.23°CLaboratory Premises & Customer PremisesActive
  • High Voltage Calibration of Measuring Devices AC Voltage (0.01 Hz to 60 Hz)-Calibration of High voltage Probe
  • Direct Calibration using Vitrek 4700 as a reference standard uisng MCL-QSD-CP-E-008 (Technical Protocol) m= measured value
  • 1 kV to 10 kV
0.12%*m+0.15 kVLaboratory Premises & Customer PremisesActive
  • > 10 kV to 75 kV
0.10%*m+1.2 kVLaboratory Premises & Customer PremisesActive
  • High Voltage Calibration of Measuring Devices DC Voltage - Calibration of High Voltage Probe
  • 1 kV to 10 kV
0.030%*m+0.10 kVLaboratory Premises & Customer PremisesActive
  • > 10 kV to 100 kV
0.050%*m+1.0 kVLaboratory Premises & Customer PremisesActive
  • High Voltage Calibration of Measuring Devices AC Voltage - Calibration of High Voltage Probe
  • Direct Calibration using Fluke 80k-40 as a reference standard uisng MCL-QSD-CP-E-008 (Technical Protocol) m= measured value
  • 0 kV to 28 kV
5.0%*m+1.2 kVLaboratory Premises & Customer PremisesActive
  • High Voltage Calibration of Measuring Devices DC Voltage - Calibration of High Voltage Probe
  • 0 kV to 40 kV
2.0%*m+1.0 kVLaboratory Premises & Customer PremisesActive
  • Insulation tester
  • Direct Calibration using Decade Resistance Box as a reference standard uisng MCL-QSD-CP-E-004 (Technical Protocol) m= measured value
  • 0 kΩ to 100 kΩ
0.10%*m+0.71 kΩLaboratory Premises & Customer PremisesActive
  • > 100 kΩ to 1 MΩ
0.10%*m+0.01 MΩLaboratory Premises & Customer PremisesActive
  • > 1MΩ to 5 MΩ
0.10%*m+0.01 MΩLaboratory Premises & Customer PremisesActive
  • > 5 MΩ to 10 MΩ
0.10%*m+0.01 MΩLaboratory Premises & Customer PremisesActive
  • > 10 MΩ to 50 MΩ
1.0% *m+0.94 MΩLaboratory Premises & Customer PremisesActive
  • > 50 MΩ to 100 MΩ
1.0%*m+0.94 MΩLaboratory Premises & Customer PremisesActive
  • > 100 MΩ to 400 MΩ
1.0%*m+24 MΩLaboratory Premises & Customer PremisesActive
  • > 400 MΩ to 1 GΩ
1.0%*m+24 MΩLaboratory Premises & Customer PremisesActive
  • > 1 GΩ to 10 GΩ
1.0%*m+0.58 GΩLaboratory Premises & Customer PremisesActive
  • > 10GΩ to 100 GΩ
1.0%*m+5.9 GΩLaboratory Premises & Customer PremisesActive
  • Energy meter (Digital & Analog) (Single Phase)
  • Direct Calibration using DRTS66 as a reference standard uisng MCL-QSD-CP-E-005 (Technical Protocol) m= measured value
  • *Voltage = 0 V to 600 V *Frequency = 45 Hz to 65 Hz *Current = 0 A to 128 A *Power Factor = 1 (Constant)
0.040%*m+5.0 WhLaboratory Premises & Customer PremisesActive
  • Energy meter (Digital & Analog) (Three Phase)
  • Direct Calibration using DRTS66 as a reference standard uisng MCL-QSD-CP-E-006 (Technical Protocol) m= measured value
  • *Voltage = 0 V to 300 V *Frequency = 45 Hz to 65 Hz *Current = 0 A to 64 A *Power Factor = 1 (Constant)
0.040%*m+6.0 WhLaboratory Premises & Customer PremisesActive
  • AC Power meter (Single Phase )
  • Direct Calibration using DRTS66 as a reference standard uisng MCL-QSD-CP-E-009 (Technical Protocol)
  • *Voltage = 0 V to 600 V *Frequency = 45 Hz to 65 Hz *Current = 0 A to 128 A *Power Factor = 1 (Constant)
0.040%*m+5.0 WhLaboratory Premises & Customer PremisesActive
  • DC Power meter (Single Phase)
  • Direct Calibration using DRTS66 as a reference standard uisng MCL-QSD-CP-E-009 (Technical Protocol) m= measured value
  • *Voltage = 0 V to 600 V *Current = 0 A to 128 A
0.40%*m+5.0 WLaboratory Premises & Customer PremisesActive
  • AC Power meter (Three Phase )
  • *Voltage = 0 V to 300 V *Frequency = 45 Hz to 65 Hz *Current = 0 A to 64 A *Power Factor = 1 (Constant)
0.040%*m+7.0 WLaboratory Premises & Customer PremisesActive
  • DC Power meter (Three Phase )
  • *Voltage = 0 V to 300 V *Current = 0 A to 64 A *Power
0.40%*m+7.0 WLaboratory Premises & Customer PremisesActive
  • DC Voltage
  • METHOD - Direct CRM USED - Fluke 8846A REFERANCE STANDARD.- Euramet Cg-15 Ver 3.0. INTERNAL PROCEDURE NUMBER - MCL-QSD-CP-E-002
  • 0 mV to 100 mV
8.8 µVLaboratory Premises & Customer PremisesActive
  • >100 mV to 1 V
45 µVLaboratory Premises & Customer PremisesActive
  • >1 V to 10 V
0.34 mVLaboratory Premises & Customer PremisesActive
  • >10 V to 100 V
5.3 mVLaboratory Premises & Customer PremisesActive
  • >100 V to 1000 V
60 mVLaboratory Premises & Customer PremisesActive
  • AC Voltage (Frequency 10 Hz to 50 kHz)
  • METHOD - Direc CRM USED - Fluke 8846A REFERANCE STANDARD Euramet Cg-15 Ver 3.0. INTERNAL PROCEDURE NUMBER - MCL-QSD-CP-E-002
  • 5 mV to 10 mV
72 µVLaboratory Premises & Customer PremisesActive
  • > 10 mV to 100 mV
0.20 mVLaboratory Premises & Customer PremisesActive
  • >100 mV to 1 V
2.0 mVLaboratory Premises & Customer PremisesActive
  • >1 V to 10 V
20 mVLaboratory Premises & Customer PremisesActive
  • >10 V to 100 V
0.20 VLaboratory Premises & Customer PremisesActive
  • >100 V to 1000 V
0.96 VLaboratory Premises & Customer PremisesActive
  • DC Current
  • 0 µA to 100 µA
88 nALaboratory Premises & Customer PremisesActive
  • > 100 µA to 1 mA
0.64 µALaboratory Premises & Customer PremisesActive
  • > 1 mA to 10 mA
8.2 µALaboratory Premises & Customer PremisesActive
  • > 10 mA to 100 mA
64 µALaboratory Premises & Customer PremisesActive
  • > 100 mA to 400 mA
0.26 mALaboratory Premises & Customer PremisesActive
  • > 400 mA to 1A
0.82 mALaboratory Premises & Customer PremisesActive
  • > 1 A to 3 A
4.2 mALaboratory Premises & Customer PremisesActive
  • > 3 A to 10 A
19 mALaboratory Premises & Customer PremisesActive
  • Resistance (2-wire or 4-wire) include Decade resistance box
  • METHOD - Direct CRM USED - Fluke 8846A REFERANCE STANDARD.- Euramet Cg-15 Ver 3.0. INTERNAL PROCEDURE NUMBER - MCL-QSD-CP-E-002
  • 0 Ω to 10 Ω
4.7 mΩLaboratory Premises & Customer PremisesActive
  • > 10 Ω to 100 Ω
17 mΩLaboratory Premises & Customer PremisesActive
  • > 100 Ω to 1kΩ
0.13 ΩLaboratory Premises & Customer PremisesActive
  • > 1 kΩ to 10 kΩ
1.3 ΩLaboratory Premises & Customer PremisesActive
  • > 10 kΩ to 100 kΩ
13 ΩLaboratory Premises & Customer PremisesActive
  • > 100 kΩ to 1 MΩ
0.13 kΩLaboratory Premises & Customer PremisesActive
  • > 1 MΩ to 10 MΩ
4.8 kΩLaboratory Premises & Customer PremisesActive
  • > 10 MΩ to 100 MΩ
0.94 MΩLaboratory Premises & Customer PremisesActive
  • > 100 MΩ to 1000 MΩ
24 MΩLaboratory Premises & Customer PremisesActive
  • AC Current (Frequency 10 Hz to 10 kHz
  • METHOD - Direct CRM USED - Fluke 8846A REFERANCE STANDARD.- Euramet Cg-15 Ver 3.0. INTERNAL PROCEDURE NUMBER - MCL-QSD-CP-E-002
  • 5 µA to 100 µA
1.3 µALaboratory Premises & Customer PremisesActive
  • > 100 µA to 1 mA
5.2 µALaboratory Premises & Customer PremisesActive
  • > 1 mA to 10 mA
0.13 mALaboratory Premises & Customer PremisesActive
  • > 10 mA to 100 mA
0.53 mALaboratory Premises & Customer PremisesActive
  • > 100 mA to 400 mA
4.3 mALaboratory Premises & Customer PremisesActive
  • > 400 mA to 1A
13 mALaboratory Premises & Customer PremisesActive
  • AC Current Frequency 10 Hz to 1 kHz
  • METHOD - Direct CRM USED - Fluke 8846A REFERANCE STANDARD.- Euramet Cg-15 Ver 3.0. INTERNAL PROCEDURE NUMBER - MCL-QSD-CP-E-002
  • > 1 A to 3 A
7.4 mALaboratory Premises & Customer PremisesActive
  • > 3 A to 10 A
25 mALaboratory Premises & Customer PremisesActive
  • Capacitance
  • 0 nF to 1 nF
55 pFLaboratory Premises & Customer PremisesActive
  • > 1 nF to 10 nF
0.18 nFLaboratory Premises & Customer PremisesActive
  • > 10 nF to 100 nF
1.8 nFLaboratory Premises & Customer PremisesActive
  • >100 nF to 1 µF
18 nFLaboratory Premises & Customer PremisesActive
  • > 1µF to 10 µF
0.18 µFLaboratory Premises & Customer PremisesActive
  • > 10 µF to 100µF
1.8 µFLaboratory Premises & Customer PremisesActive
  • > 100µF to 1 mF
18 µFLaboratory Premises & Customer PremisesActive
  • > 1 mF to 10mF
0.18 mFLaboratory Premises & Customer PremisesActive
  • Frequency
  • 3 Hz to 10 Hz
8.2 mHzLaboratory Premises & Customer PremisesActive
  • > 10 Hz to 40 Hz
16 mHzLaboratory Premises & Customer PremisesActive
  • > 40 Hz to 300 kHz
68 HzLaboratory Premises & Customer PremisesActive
  • > 300kHz to 1000 kHz
0.13 kHzLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (RTD)
  • METHOD - Direct CRM USED - Fluke 8846A REFERANCE STANDARD.- Euramet Cg-11 Ver 2.0 INTERNAL PROCEDURE NUMBER - MCL-QSD-CP-E-003
  • -200 °C to 800 °C
0.034 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (K- Type Thermocouple)
  • -200 °C to 1372 °C
0.50 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (J- Type Thermocouple)
  • -210 °C to 1200 °C
0.36 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (N- Type Thermocouple)
  • -200 °C to 1300 °C
0.50 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (R- Type Thermocouple)
  • 0 °C to 1700 °C
0.69 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (S- Type Thermocouple)
  • -250 °C to 1700 °C
0.58 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device(B- Type Thermocouple)
  • 600 °C to 1820 °C
0.54 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (C- Type Thermocouple)
  • 1000 °C to 2316 °C
0.99 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (E- Type Thermocouple)
  • -250 °C to 1000 °C
0.61 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (L- Type Thermocouple)
  • -200 °C to 900 °C
0.47 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (T- Type Thermocouple)
  • -250 °C to 400 °C
0.75 °CLaboratory Premises & Customer PremisesActive
  • Temperature Measuring Device (U- Type Thermocouple)
  • -200 °C to 600 °C
0.68 °CLaboratory Premises & Customer PremisesActive
  • Decade Resistance box
  • METHOD - Direct method CRM USED - Fluke 1550C REFERANCE STANDARD.- SANAS -TG-02-02 INTERNAL PROCEDURE NUMBER - MCL-QSD-CP-E-007
  • 0 kΩ to 250 kΩ
16 kΩLaboratory Premises & Customer PremisesActive
  • > 250 kΩ to 1MΩ
59 kΩLaboratory Premises & Customer PremisesActive
  • > 1MΩ to 5MΩ
0.29 MΩLaboratory Premises & Customer PremisesActive
  • > 5MΩ to 10MΩ
0.58 MΩLaboratory Premises & Customer PremisesActive
  • > 10MΩ to 50MΩ
2.9 MΩLaboratory Premises & Customer PremisesActive
  • METHOD - Direct method CRM USED - Fluke 1550C REFERANCE STANDARD.- SANAS -TG-02-02 INTERNAL PROCEDURE NUMBER - MCL-QSD-CP-E-007
  • > 50MΩ to 100MΩ
5.8 MΩLaboratory Premises & Customer PremisesActive
  • > 100MΩ to 400MΩ
24 MΩLaboratory Premises & Customer PremisesActive
  • > 400MΩ to 1 GΩ
59 MΩLaboratory Premises & Customer PremisesActive
  • > 1 GΩ to 10 GΩ
0.58 GΩLaboratory Premises & Customer PremisesActive
  • > 10GΩ to 100 GΩ
5.9 GΩLaboratory Premises & Customer PremisesActive
  • > 100GΩ to 1TΩ
0.24 TΩLaboratory Premises & Customer PremisesActive
  • High Voltage AC Voltage (50 Hz to 60Hz)-Calibration of High voltage Source
  • METHOD - Direct CRM USED - Vitrek 4700 REFERANCE STANDARD.- IEC 60060:2010 . INTERNAL PROCEDURE NUMBER - MCL-QSD-CP-E-008
  • 0 kV to 10 kV
0.15 kVLaboratory Premises & Customer PremisesActive
  • > 10 kV to 100 kV
1.2 kVLaboratory Premises & Customer PremisesActive
  • High Voltage DC Voltage Calibration of High Voltage Source
  • 1 kV to 10 kV
0.03 % U + 0.10 kVLaboratory Premises & Customer PremisesActive
  • >10kV to 100 kV
0.05 % U + 1.0 kVLaboratory Premises & Customer PremisesActive
  • High Voltage Calibration of Measuring Devices AC Voltage Calibration of High Voltage Source
  • Direct Calibration using Fluke 80k-40 as a reference standard uisng MCL-QSD-CP-E-008 (Technical Protocol)
  • 0 kV to 28 kV
5.0%*m+1.2 kVLaboratory Premises & Customer PremisesActive
  • High Voltage Calibration of Measuring Devices DC Voltage - Calibration of High Voltage Source
  • 0 kV to 40 kV
2.0%*m+1.0 kVLaboratory Premises & Customer PremisesActive