| Measured Quantity / Calibration Instrument |
Calibration Method |
Range and Specification |
Expanded Measurement |
Location |
Status |
| Balance & Scale |
- Top loading weighing scale
| | | | | Active
|
| Time and Frequency |
| | | 2.6 x 10-11 | Laboratory | Active
|
| 1.2 x 10-11 | Laboratory | Active
|
- Frequency counter or frequency meter
| | | 1.6 x 10-11 | Laboratory | Active
|
| 1.6 x 10-11 | Laboratory | Active
|
| 1.6 x 10-11 | Laboratory | Active
|
| 1.7 x 10-10 | Laboratory | Active
|
| 3.3 x 10-11 | Laboratory | Active
|
| 4.6 x 10-11 | Laboratory | Active
|
- Time Interval – Stopwatches and timers
| | | 0.48 s | Laboratory | Active
|
- Time Interval – Local clock
| | | 0.76 s | Laboratory | Active
|
- Time scale difference - Local clock vs. UTC
| | 0.76 s | Laboratory | Active
|
| - Procedure CP-E-27 Calibration of Non Contact Tachometers
| | 0.0018 rpm | Laboratory | Active
|
| 0.0060 rpm | Laboratory | Active
|
- 1,000.0 rpm to 9,999.9 rpm
| 0.058 rpm | Laboratory | Active
|
| 0.58 rpm | Laboratory | Active
|
- 100,000 rpm to 199,800 rpm
| 5.8 rpm | Laboratory | Active
|
| Mass and Balance |
| - CP-M-02 “Calibration of Mass Standards” and CP-M-03 “Weighing Designs”
| | 4.9 g | Laboratory | Active
|
| 1.9 g | Laboratory | Active
|
| 0.25 g | Laboratory | Active
|
| 80 mg | Laboratory | Active
|
| 10 mg | Laboratory | Active
|
| 1.6 mg | Laboratory | Active
|
| 0.80 mg | Laboratory | Active
|
| 0.30 mg | Laboratory | Active
|
| 0.16 mg | Laboratory | Active
|
| 0.080 mg | Laboratory | Active
|
| 0.030 mg | Laboratory | Active
|
| 0.016 mg | Laboratory | Active
|
| 0.010 mg | Laboratory | Active
|
| 0.0080 mg | Laboratory | Active
|
| 0.0060 mg | Laboratory | Active
|
| 0.0050 mg | Laboratory | Active
|
| 0.0040 mg | Laboratory | Active
|
| 0.0030 mg | Laboratory | Active
|
| 0.0025 mg | Laboratory | Active
|
| 0.0020 mg | Laboratory | Active
|
| 0.0016 mg | Laboratory | Active
|
| 0.0012 mg | Laboratory | Active
|
| 0.0010 mg | Laboratory | Active
|
| 0.0010 mg | Laboratory | Active
|
| 0.0010 mg | Laboratory | Active
|
| 0.0010 mg | Laboratory | Active
|
| 0.0010 mg | Laboratory | Active
|
- Mass/ Electronic Balances
| - CP-M-01 “Calibration of NAWI’s”, Weights are available in OIML Classes: • E2: 1 mg to 5 kg; max grouped load 11.11 kg. • F1: 1 mg to 50 kg; max grouped load 171.1 kg
| | 740 mg | Customer premises | Active
|
| 660 mg | Customer premises | Active
|
| 140 mg | Customer premises | Active
|
| 46 mg | Customer premises | Active
|
| 25 mg | Customer premises | Active
|
| 3.8 mg | Customer premises | Active
|
| 1.5 mg | Customer premises | Active
|
| 0.76 mg | Customer premises | Active
|
| 0.38 mg | Customer premises | Active
|
| 0.15 mg | Customer premises | Active
|
| 0.078 mg | Customer premises | Active
|
| 0.046 mg | Customer premises | Active
|
| 0.038 mg | Customer premises | Active
|
| 0.031 mg | Customer premises | Active
|
| 0.024 mg | Customer premises | Active
|
| 0.018 mg | Customer premises | Active
|
| 0.015 mg | Customer premises | Active
|
| 0.012 mg | Customer premises | Active
|
| 0.010 mg | Customer premises | Active
|
| Temperature |
- Resistance thermometers with display unit
| - Comparison with platinum resistance thermometer in a bath. EMI procedure: CP-T-01
| | 0.015 °C | Laboratory | Active
|
| 0.020 °C | Laboratory | Active
|
| 0.025 °C | Laboratory | Active
|
- Comparison with platinum resistance thermometers, utilizing the Zn fixed point. Applies for thermometers longer than 40 cm. EMI procedure: CP-T-01
| - >250°C to 419.527 °C (Zn fixed point)
| 0.025 °C | Laboratory | Active
|
- Comparison with platinum resistance thermometers, utilizing the Zn and Al fixed points. Applies for thermometers longer than 40 cm. EMI procedure: CP-T-01
| - >250 °C to 660.323 °C (Al fixed point)
| 0.025 °C | Laboratory | Active
|
- Comparison with platinum resistance thermometer in a block calibrator. EMI procedure: CP-T-01
| | 0.15 °C to 0.27 °C | Laboratory | Active
|
- Thermocouples with display unit
| - Comparison with platinum resistance thermometer in a bath. EMI procedure: CP-T-01
| | 0.2 °C | Laboratory | Active
|
| 0.4 °C | Laboratory | Active
|
- Comparison with platinum resistance thermometer in a block calibrator. EMI procedure: CP-T-01
| | 0.4 °C to 0.8 °C | Laboratory | Active
|
- Temperature block calibrators
| - Comparison with platinum resistance thermometer. EMI procedure: CP-T-03
| | 0.2 °C | Laboratory | Active
|
- Platinum Resistance Thermometers
| - Comparison with platinum resistance thermometers in a bath. EMI procedure: CP-T-04
| | 0.010 °C | Laboratory | Active
|
| 0.015 °C | Laboratory | Active
|
| 0.020 °C | Laboratory | Active
|
- Comparison with platinum resistance thermometers in Zn fixed point. EMI procedure: CP-T-04
| - 419.527 °C (Zn fixed point)
| 0.005 °C | Laboratory | Active
|
- Comparison with platinum resistance thermometers in Al fixed point. EMI procedure: CP-T-04
| - 660.323 °C (Al fixed point)
| 0.020 °C | Laboratory | Active
|
- Comparison with platinum resistance thermometers, utilizing the Zn fixed point. Applies for thermometers longer than 40 cm. EMI procedure: CP-T-04
| - >250°C to 419.527 °C (Zn fixed point)
| 0.020 °C | Laboratory | Active
|
- Comparison with platinum resistance thermometers, utilizing the Zn and Al fixed points. Applies for thermometers longer than 40 cm. EMI procedure: CP-T-04
| - >250 °C to 660.323 °C (Al fixed point)
| 0.020 °C | Laboratory | Active
|
- Comparison with platinum resistance thermometers in a block calibrator. EMI procedure: CP-T-04
| | 0.15 °C to 0.27 °C | Laboratory | Active
|
| - Comparison with reference thermometer in an air chamber. EMI procedure: CP-T-02
| | 0.10 °C to 0.30 °C | Laboratory | Active
|
- SPRT Calibration at ITS-90 Fixed Points
| - Triple point of mercury (Hg). EMI procedure: CP-T-10
| | 0.6 mK | Laboratory | Active
|
- Triple point of water. EMI procedure: CP-T-10
| | 0.3 mK | Laboratory | Active
|
- Melting point of Gallium (Ga) EMI procedure: CP-T-10
| | 0.6 mK | Laboratory | Active
|
- Freezing point of Indium (In). EMI procedure: CP-T-10
| | 1.7 mK | Laboratory | Active
|
- Freezing point of Tin (Sn). EMI procedure: CP-T-10
| | 1.6 mK | Laboratory | Active
|
- Freezing point of Zinc (Zn). EMI procedure: CP-T-10
| | 1.9 mK | Laboratory | Active
|
- Freezing point of Aluminium (Al). EMI procedure: CP-T-10
| | 16 mK | Laboratory | Active
|
- SPRT Calibration at ITS-90 Fixed Point Sub-Ranges
| - Fixed points Hg to H2O EMI procedure: CP-T-10
| | 0.7 mK | Laboratory | Active
|
- Fixed points H2O to Ga EMI procedure: CP-T-10
| | 0.7 mK | Laboratory | Active
|
- Fixed points Ga to In EMI procedure: CP-T-10
| - 29.7646 °C to 156.5985 °C
| 1.8 mK | Laboratory | Active
|
- Fixed points In to Sn EMI procedure: CP-T-10
| - 156.5985 °C to 231.928 °C
| 2.0 mK | Laboratory | Active
|
- Fixed points Sn to Zn EMI procedure: CP-T-10
| | 3.0 mK | Laboratory | Active
|
- Fixed points Zn to Al EMI procedure: CP-T-10
| | 3 mK to 16 mK | Laboratory | Active
|
- Calibration of Climatic Chambers
| - DKD-R 5-7. EMI procedure: CP-T-05
| | 0.2 °C | Customer’s Premises | Active
|
- Calibration of Autoclaves
| | | 0.2 °C | Customer’s Premises | Active
|
| - Comparison calibration in baths and furnaces. EMI procedure: CP-T-07
| | 0.2 °C to 0.4 °C | Laboratory | Active
|
| 0.6 °C to 1.3 oC | Laboratory | Active
|
- Noble metal thermocouples
| | 0.2 °C to 0.4°C | Laboratory | Active
|
| 0.6 °C to 1.0 °C | Laboratory | Active
|
| Humidity |
- Calibration of dew point meters for relative humidity
| - Calibration in chamber of humidity generator. EMI procedure: CP-T-02
| - 10 %rh to 95 %rh at air temperature from 10 °C to 45 °C
| 0.3 %rh to 1.0 %rh | Laboratory | Active
|
- 10 %rh to 95 %rh at air temperature from 45 °C to 70 °C
| 0.4 %rh to 1.6 %rh | Laboratory | Active
|
- Calibration of relative humidity meters for relative humidity
| - 10 %rh to 95 %rh at air temperature from 10 °C to 45 °C
| 0.4 %rh to 1.1 %rh | Laboratory | Active
|
- 10 %rh to 95 %rh at air temperature from 45 °C to 70 °C
| 0.5 %rh to 1.7 %rh | Laboratory | Active
|
- Calibration of climatic chambers, humidity measurements
| - DKD-R 5-7. EMI procedure: CP-T-05
| - 10 %rh to 90 %rh at air temperature from 10 °C to 50 °C
| 0.6 %rh to 2 %rh | Customer’s Premises | Active
|
| Electrical |
- Solid state DC voltage standards
| - Procedure CP-E-03 Calibration of voltage reference standards
| | 7.3 μV | Laboratory | Active
|
| 2.6 μV | Laboratory | Active
|
| - Procedure CP-E-20 Using MI 6010D Bridge and Range Extender R = Measured Value
| | 8.8 ×10-6·R | Laboratory | Active
|
| 6.6×10-6·R | Laboratory | Active
|
| 3.4 ×10-6·R | Laboratory | Active
|
| 0.30 ×10-6·R | Laboratory | Active
|
| 0.28 ×10-6·R | Laboratory | Active
|
| 0.33 ×10-6 R | Laboratory | Active
|
| 0.26 ×10-6 R | Laboratory | Active
|
| 0.27 ×10-6 R | Laboratory | Active
|
- Procedure CP-E-17. Using MI 6000B Bridge R = Measured Value
| | 2.0 ×10-6·R | Laboratory | Active
|
| 4.0 ×10-6·R | Laboratory | Active
|
| 12 ×10-6·R | Laboratory | Active
|
| 19 ×10-6·R | Laboratory | Active
|
| 60 ×10-6·R | Laboratory | Active
|
- DC resistance Calibration of Resistor Decades
| - Procedure CP-E-23 Calibration of Resistors and Decade Resistors by Direct Reading R = measured resistance value
| | 0.05 mΩ | Laboratory | Active
|
| 50 ×10-6·R | Laboratory | Active
|
| 10 ×10-6·R | Laboratory | Active
|
| 7.0 ×10-6·R | Laboratory | Active
|
| 7.0 ×10-6·R | Laboratory | Active
|
| - Procedure CP-E-12 Calibration of DCC Resistance Bridges and Range Extender
| | 0.08 ×10-6 | Laboratory | Active
|
| 2.9 ×10-6 | Laboratory | Active
|
| 5.8 ×10-6 | Laboratory | Active
|
| 10 ×10-6 | Laboratory | Active
|
- DC Voltage Calibration of Measuring Instruments
| - Procedure CP-E-11 Calibration of Digital Multimeters Procedure CP-E-24 Calibration of Process Calibrators U = Measured Value
| | 5.8 ×10-6 U + 1.0 μV | Laboratory | Active
|
| 5.0 ×10-6 U + 1.0 μV | Laboratory | Active
|
| 3.6 ×10-6 U + 2.6 μV | Laboratory | Active
|
| 3.8 ×10-6 U + 3.8 μV | Laboratory | Active
|
| 5.4 ×10-6 U + 39 μV | Laboratory | Active
|
| 10 ×10-6 U + 0.31 mV | Laboratory | Active
|
- Procedure CP-E-06 Calibration of 8.5 digit Digital Multimeters Using MI 8000A bridge U = Measured Value
| | 0.62 μV | Laboratory | Active
|
| 0.40 ×10-6 U + 0.51 μV | Laboratory | Active
|
| 0.57 ×10-6 U + 0.17 μV | Laboratory | Active
|
| 1.3 ×10-6 U | Laboratory | Active
|
| 1.9 ×10-6 U | Laboratory | Active
|
| 6.6 ×10-6 U | Laboratory | Active
|
- DC Voltage Calibration of sources
| - Procedure CP-E-18 Calibration of Calibrators Procedure CP-E-24 Calibration of Process Calibrators U = Measured Value
| | 3.4 ×10-6 U + 0.88 μV | Laboratory | Active
|
| 5.4 ×10-6 U + 0.55 μV | Laboratory | Active
|
| 5.6 ×10-6 U + 0.55 μV | Laboratory | Active
|
| 8.3 ×10-6 U + 30 μV | Laboratory | Active
|
| 11 ×10-6 U + 0.42 mV | Laboratory | Active
|
- Procedure CP-E-04 Calibration of High Performance Calibrators Using MI 8000A bridge U = Measured Value
| | 0.62 μV | Laboratory | Active
|
| 0.40 ×10-6 U + 0.51 μV | Laboratory | Active
|
| 0.57 ×10-6 U + 0.16 μV | Laboratory | Active
|
| 1.3 ×10-6 U | Laboratory | Active
|
| 1.9 ×10-6 U | Laboratory | Active
|
| 6.6 ×10-6 U | Laboratory | Active
|
- AC Voltage Calibration of Measuring Instruments
| - Procedure CP-E-11 Calibration of Digital Multimeters Procedure CP-E-26 Calibration of Touch Current and Protective Conductor Current Measuring Instruments U = Measured Value
| - (600 µV to 2.2 Mv) 10 Hz to 20 Hz
| 0.15 ×10-3 U + 1.3 μV | Laboratory | Active
|
- (600 µV to 2.2 Mv) >20 Hz to 40 Hz
| 0.11 ×10-3 U + 1.3 μV | Laboratory | Active
|
- (600 µV to 2.2 Mv) >40 Hz to 20 kHz
| 94 ×10-6 U + 1.3 μV | Laboratory | Active
|
- (600 µV to 2.2 Mv) >20 kHz to 50 kHz
| 0.14 ×10-3 U + 2.0 μV | Laboratory | Active
|
- (600 µV to 2.2 Mv) >50 kHz to 100 kHz
| 0.14 ×10-3 U + 2.5 μV | Laboratory | Active
|
- (600 µV to 2.2 mV) >100 kHz to 300 kHz
| 0.41 ×10-3 U + 4.0 μV | Laboratory | Active
|
- (600 µV to 2.2 mV) >300 kHz to 500 kHz
| 1.3 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (600 µV to 2.2 mV) >500 kHz to 1 MHz
| 4.5 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>2.2 mV to 7 mV) 10 Hz to 20 Hz
| 0.12 ×10-3 U + 1.3 μV | Laboratory | Active
|
- (>2.2 mV to 7 mV) >20 Hz to 40 Hz
| 72 ×10-6 U + 1.3 μV | Laboratory | Active
|
- (>2.2 mV to 7 mV) >40 Hz to 20 kHz
| 69 ×10-6 U + 1.3 μV | Laboratory | Active
|
- (>2.2 mV to 7 mV) >20 kHz to 50 kHz
| 82 ×10-6 U + 2.0 μV | Laboratory | Active
|
- (>2.2 mV to 7 mV) >50 kHz to 100 kHz
| 87 ×10-6 U + 2.5 μV | Laboratory | Active
|
- (>2.2 mV to 7 mV) >100 kHz to 300 kHz
| 0.23 ×10-3 U + 4.0 μV | Laboratory | Active
|
- (>2.2 mV to 7 mV) >300 kHz to 500 kHz
| 0.75 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>2.2 mV to 7 mV) >500 kHz to 1 MHz
| 3.5 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>7 mV to 22 mV) 10 Hz to 20 Hz
| 91 ×10-6 U + 1.3 μV | Laboratory | Active
|
- (>7 mV to 22 mV) >20 Hz to 40 Hz
| 56 ×10-6 U + 1.3 μV | Laboratory | Active
|
- (>7 mV to 22 mV) >40 Hz to 20 kHz
| 53 ×10-6 U + 1.3 μV | Laboratory | Active
|
- (>7 mV to 22 mV) >20 kHz to 50 kHz
| 69 ×10-6 U + 2.0 μV | Laboratory | Active
|
- (>7 mV to 22 mV) >50 kHz to 100 kHz
| 78 ×10-6 U + 2.5 μV | Laboratory | Active
|
- (>7 mV to 22 mV) >100 kHz to 300 kHz
| 0.17 ×10-3 U + 4.0 μV | Laboratory | Active
|
- (>7 mV to 22 mV) >300 kHz to 500 kHz
| 0.62 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>7 mV to 22 mV) >500 kHz to 1 MHz
| 2.6 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>22 mV to 70 mV) 10 Hz to 20 Hz
| 85 ×10-6 U + 1.5 μV | Laboratory | Active
|
- (>22 mV to 70 mV) >20 Hz to 40 Hz
| 52 ×10-6 U + 1.5 μV | Laboratory | Active
|
- (>22 mV to 70 mV) >40 Hz to 20 kHz
| 50 ×10-6 U + 1.5 μV | Laboratory | Active
|
- Procedure CP-E-11 Calibration of Digital Multimeters Procedure CP-E-26 Calibration of Touch Current and Protective Conductor Current Measuring InstrumentsU = Measured Value
| - (>22 mV to 70 mV) >20 kHz to 50 kHz
| 54 ×10-6 U + 2.0 μV | Laboratory | Active
|
- (>22 mV to 70 mV) >50 kHz to 100 kHz
| 70 ×10-6 U + 2.5 μV | Laboratory | Active
|
- (>22 mV to 70 mV) >100 kHz to 300 kHz
| 0.18 ×10-3 U + 4.0 μV | Laboratory | Active
|
- (>22 mV to 70 mV) >300 kHz to 500 kHz
| 0.33 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>22 mV to 70 mV) >500 kHz to 1 MHz
| 1.3 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>70 mV to 220 mV) 10 Hz to 20 Hz
| 64 ×10-6 U + 1.5 μV | Laboratory | Active
|
- (>70 mV to 220 mV) >20 Hz to 40 Hz
| 36 ×10-6 U + 1.5 μV | Laboratory | Active
|
- (>70 mV to 220 mV) >40 Hz to 20 kHz
| 34 ×10-6 U + 1.5 μV | Laboratory | Active
|
- (>70 mV to 220 mV) >20 kHz to 50 kHz
| 34 ×10-6 U + 2.0 μV | Laboratory | Active
|
- (>70 mV to 220 mV) >50 kHz to 100 kHz
| 60 ×10-6 U + 2.5 μV | Laboratory | Active
|
- (>70 mV to 220 mV) >100 kHz to 300 kHz
| 0.18 ×10-3 U + 4.0 μV | Laboratory | Active
|
- Procedure CP-E-11 Calibration of Digital Multimeters Procedure CP-E-26 Calibration of Touch Current and Protective Conductor Current Measuring Instruments U = Measured Value
| - (>70 mV to 220 mV) >300 kHz to 500 kHz
| 0.32 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>70 mV to 220 mV) >500 kHz to 1 MHz
| 1.2 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>220 mV to 700 mV) 10 Hz to 20 Hz
| 64 ×10-6 U + 1.5 μV | Laboratory | Active
|
- (>220 mV to 700 mV) >20 Hz to 40 Hz
| 37 ×10-6 U + 1.5 μV | Laboratory | Active
|
- (>220 mV to 700 mV) >40 Hz to 20 kHz
| 34 ×10-6 U + 1.5 μV | Laboratory | Active
|
- (>220 mV to 700 mV) >20 kHz to 50 kHz
| 34 ×10-6 U + 2.0 μV | Laboratory | Active
|
- (>220 mV to 700 mV) >50 kHz to 100 kHz
| 60 ×10-6 U + 2.5 μV | Laboratory | Active
|
- (>220 mV to 700 mV) >100 kHz to 300 kHz
| 0.18 ×10-3 U + 4.0 μV | Laboratory | Active
|
- (>220 mV to 700 mV) >300 kHz to 500 kHz
| 0.32 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>220 mV to 700 mV) >500 kHz to 1 MHz
| 1.2 ×10-3 U + 8.0 μV | Laboratory | Active
|
- Procedure CP-E-11 Calibration of Digital Multimeters Procedure CP-E-26 Calibration of Touch Current and Protective Conductor Current Measuring Instruments U = Measured Value
| - (>700 mV to 2.2 V) 10 Hz to 20 Hz
| 64 ×10-6 U | Laboratory | Active
|
- (>700 mV to 2.2 V) >20 Hz to 40 Hz
| 37 ×10-6 U | Laboratory | Active
|
- (>700 mV to 2.2 V) >40 Hz to 20 kHz
| 30 ×10-6 U | Laboratory | Active
|
- (>700 mV to 2.2 V) >20 kHz to 50 kHz
| 34 ×10-6 U | Laboratory | Active
|
- (>700 mV to 2.2 V) >50 kHz to 100 kHz
| 58 ×10-6 U | Laboratory | Active
|
- (>700 mV to 2.2 V) >100 kHz to 300 kHz
| 0.17 ×10-3 U | Laboratory | Active
|
- (>700 mV to 2.2 V) >300 kHz to 500 kHz
| 0.29 ×10-3 U | Laboratory | Active
|
- (>700 mV to 2.2 V) >500 kHz to 1 MHz
| 1.2 ×10-3 U | Laboratory | Active
|
- (>2.2 V to 7 V) 10 Hz to 20 Hz
| 63 ×10-6 U | Laboratory | Active
|
- (>2.2 V to 7 V) >20 Hz to 40 Hz
| 37 ×10-6 U | Laboratory | Active
|
- (>2.2 V to 7 V) >40 Hz to 20 kHz
| 28 ×10-6 U | Laboratory | Active
|
- (>2.2 V to 7 V) >20 kHz to 50 kHz
| 36 ×10-6 U | Laboratory | Active
|
- (>2.2 V to 7 V) >50 kHz to 100 kHz
| 74 ×10-6 U | Laboratory | Active
|
- (>2.2 V to 7 V) >100 kHz to 300 kHz
| 0.18 ×10-3 U | Laboratory | Active
|
- (>2.2 V to 7 V) >300 kHz to 500 kHz
| 0.45 ×10-3 U | Laboratory | Active
|
- (>2.2 V to 7 V) >500 kHz to 1 MHz
| 1.5 ×10-3 U | Laboratory | Active
|
- (>7 V to 22 V) 10 Hz to 20 Hz
| 63 ×10-6 U | Laboratory | Active
|
- (>7 V to 22 V) >20 Hz to 40 Hz
| 38 ×10-6 U | Laboratory | Active
|
- (>7 V to 22 V) >40 Hz to 20 kHz
| 28 ×10-6 U | Laboratory | Active
|
- (>7 V to 22 V) >20 kHz to 50 kHz
| 36 ×10-6 U | Laboratory | Active
|
- (>7 V to 22 V) >50 kHz to 100 kHz
| 70 ×10-6 U | Laboratory | Active
|
- (>7 V to 22 V) >100 kHz to 300 kHz
| 0.19 ×10-3 U | Laboratory | Active
|
- (>7 V to 22 V) >300 kHz to 500 kHz
| 0.46 ×10-3 U | Laboratory | Active
|
- (>7 V to 22 V) >500 kHz to 1 MHz
| 1.5 ×10-3 U | Laboratory | Active
|
- (>22 V to 70 V) 10 Hz to 20 Hz
| 64 ×10-6 U + 1.6 μV | Laboratory | Active
|
- (>22 V to 70 V) >20 Hz to 40 Hz
| 40 ×10-6 U + 2.6 μV | Laboratory | Active
|
- (>22 V to 70 V) >40 Hz to 20 kHz
| 35 ×10-6 U + 2.9 μV | Laboratory | Active
|
- (>22 V to 70 V) >20 kHz to 50 kHz
| 40 ×10-6 U + 2.6 μV | Laboratory | Active
|
- (>22 V to 70 V) >50 kHz to 100 kHz
| 86 ×10-6 U + 1.2 μV | Laboratory | Active
|
- (>22 V to 70 V) >100 kHz to 300 kHz
| 0.19 ×10-3 U | Laboratory | Active
|
- (>22 V to 70 V) >300 kHz to 500 kHz
| 0.50 ×10-3 U | Laboratory | Active
|
- (>22 V to 70 V) >500 kHz to 1 MHz
| 1.5 ×10-3 U | Laboratory | Active
|
- (>70 V to 220 V) 10 Hz to 20 Hz
| 66 ×10-6 U | Laboratory | Active
|
- (>70 V to 220 V) >20 Hz to 40 Hz
| 42 ×10-6 U | Laboratory | Active
|
- (>70 V to 220 V) >40 Hz to 20 kHz
| 37 ×10-6 U | Laboratory | Active
|
- (>70 V to 220 V) >20 kHz to 50 kHz
| 51 ×10-6 U | Laboratory | Active
|
- (>70 V to 220 V) >50 kHz to 100 kHz
| 89 ×10-6 U | Laboratory | Active
|
- (>220 V to 700 V) 40 Hz to 20 kHz
| 34 ×10-6 U + 30 μV | Laboratory | Active
|
- (>220 V to 700 V) >20 kHz to 50 kHz
| 0.15 ×10-3 U + 7.2 μV | Laboratory | Active
|
- (>220 V to 700 V) >50 kHz to 100 kHz
| 0.86 ×10-3 U + 1.2 μV | Laboratory | Active
|
- (>700 V to 1000 V) 40 Hz to 20 kHz
| 34 ×10-6 U + 13 μV | Laboratory | Active
|
- AC voltage Calibration of sources
| - Procedure CP-E-18 Calibration of Electrical Calibrators U = Measured Value
| - (600 µV to 2.2 mV) 10 Hz to 20 Hz
| 0.15 ×10-3 U + 1.3 μV | Laboratory | Active
|
- (600 µV to 2.2 mV) >20 Hz to 40 Hz
| 0.11 ×10-3 U + 1.3 μV | Laboratory | Active
|
- (600 µV to 2.2 mV) >40 Hz to 20 kHz
| 94 ×10-6 U + 1.3 μV | Laboratory | Active
|
- (600 µV to 2.2 mV) >20 kHz to 50 kHz
| 0.14 ×10-3 U + 2.0 μV | Laboratory | Active
|
- (600 µV to 2.2 mV) >50 kHz to 100 kHz
| 0.14 ×10-3 U + 2.5 μV | Laboratory | Active
|
- (600 µV to 2.2 mV) >100 kHz to 300 kHz
| 0.41 ×10-3 U + 4.0 μV | Laboratory | Active
|
- (600 µV to 2.2 mV) >300 kHz to 500 kHz
| 1.3 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (600 µV to 2.2 mV) >500 kHz to 1 MHz
| 4.5 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>2.2 mV to 7 mV) 10 Hz to 20 Hz
| 0.12 ×10-3 U + 1.3 μV | Laboratory | Active
|
- (>2.2 mV to 7 mV) >20 Hz to 40 Hz
| 72 ×10-6 U + 1.3 μV | Laboratory | Active
|
- (>2.2 mV to 7 mV) >40 Hz to 20 kHz
| 69 ×10-6 U + 1.3 μV | Laboratory | Active
|
- Procedure CP-E-18 Calibration of Electrical Calibrators U = Measured Value
| - (>2.2 mV to 7 mV) >20 kHz to 50 kHz
| 82 ×10-6 U + 2.0 μV | Laboratory | Active
|
- (>2.2 mV to 7 mV) >50 kHz to 100 kHz
| 87 ×10-6 U + 2.5 μV | Laboratory | Active
|
- (>2.2 mV to 7 mV) >100 kHz to 300 kHz
| 0.23 ×10-3 U + 4.0 μV | Laboratory | Active
|
- (>2.2 mV to 7 mV) >300 kHz to 500 kHz
| 0.75 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>2.2 mV to 7 mV) >500 kHz to 1 MHz
| 3.5 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>7 mV to 22 mV) 10 Hz to 20 Hz
| 91 ×10-6 U + 1.3 μV | Laboratory | Active
|
- (>7 mV to 22 mV) >20 Hz to 40 Hz
| 56 ×10-6 U + 1.3 μV | Laboratory | Active
|
- (>7 mV to 22 mV) >40 Hz to 20 kHz
| 53 ×10-6 U + 1.3 μV | Laboratory | Active
|
- (>7 mV to 22 mV) >20 kHz to 50 kHz
| 69 ×10-6 U + 2.0 μV | Laboratory | Active
|
- (>7 mV to 22 mV) >50 kHz to 100 kHz
| 78 ×10-6 U + 2.5 μV | Laboratory | Active
|
- (>7 mV to 22 mV) >100 kHz to 300 kHz
| 0.17 ×10-3 U + 4.0 μV | Laboratory | Active
|
- Procedure CP-E-18 Calibration of Electrical Calibrators U = Measured Value
| - (>7 mV to 22 mV) >300 kHz to 500 kHz
| 0.62 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>7 mV to 22 mV) >500 kHz to 1 MHz
| 2.6 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>22 mV to 70 mV) 10 Hz to 20 Hz
| 85 ×10-6 U + 1.5 μV | Laboratory | Active
|
- (>22 mV to 70 mV) >20 Hz to 40 Hz
| 52 ×10-6 U + 1.5 μV | Laboratory | Active
|
- (>22 mV to 70 mV) >40 Hz to 20 kHz
| 50 ×10-6 U + 1.5 μV | Laboratory | Active
|
- (>22 mV to 70 mV) >20 kHz to 50 kHz
| 54 ×10-6 U + 2.0 μV | Laboratory | Active
|
- (>22 mV to 70 mV) >50 kHz to 100 kHz
| 70 ×10-6 U + 2.5 μV | Laboratory | Active
|
- (>22 mV to 70 mV) >100 kHz to 300 kHz
| 0.18 ×10-3 U + 4.0 μV | Laboratory | Active
|
- (>22 mV to 70 mV) >300 kHz to 500 kHz
| 0.33 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>22 mV to 70 mV) >500 kHz to 1 MHz
| 1.3 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>70 mV to 220 mV) 10 Hz to 20 Hz
| 64 ×10-6 U + 1.5 μV | Laboratory | Active
|
- (>70 mV to 220 mV) >20 Hz to 40 Hz
| 36 ×10-6 U + 1.5 μV | Laboratory | Active
|
- (>70 mV to 220 mV) >40 Hz to 20 kHz
| 34 ×10-6 U + 1.5 μV | Laboratory | Active
|
- (>70 mV to 220 mV) >20 kHz to 50 kHz
| 34 ×10-6 U + 2.0 μV | Laboratory | Active
|
- (>70 mV to 220 mV) >50 kHz to 100 kHz
| 60 ×10-6 U + 2.5 μV | Laboratory | Active
|
- (>70 mV to 220 mV) >100 kHz to 300 kHz
| 0.18 ×10-3 U + 4.0 μV | Laboratory | Active
|
- (>70 mV to 220 mV) >300 kHz to 500 kHz
| 0.32 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>70 mV to 220 mV) >500 kHz to 1 MHz
| 1.2 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>220 mV to 700 mV) 10 Hz to 20 Hz
| 64 ×10-6 U + 1.5 μV | Laboratory | Active
|
- (>220 mV to 700 mV) >20 Hz to 40 Hz
| 37 ×10-6 U + 1.5 μV | Laboratory | Active
|
- (>220 mV to 700 mV) >40 Hz to 20 kHz
| 34 ×10-6 U + 1.5 μV | Laboratory | Active
|
- Procedure CP-E-18 Calibration of Electrical Calibrators U = Measured Value
| - (>220 mV to 700 mV) >20 kHz to 50 kHz
| 34 ×10-6 U + 2.0 μV | Laboratory | Active
|
- (>220 mV to 700 mV) >50 kHz to 100 kHz
| 60 ×10-6 U + 2.5 μV | Laboratory | Active
|
- (>220 mV to 700 mV) >100 kHz to 300 kHz
| 0.18 ×10-3 U + 4.0 μV | Laboratory | Active
|
- (>220 mV to 700 mV) >300 kHz to 500 kHz
| 0.32 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>220 mV to 700 mV) >500 kHz to 1 MHz
| 1.2 ×10-3 U + 8.0 μV | Laboratory | Active
|
- (>700 mV to 2.2 V) 10 Hz to 20 Hz
| 64 ×10-6 U | Laboratory | Active
|
- (>700 mV to 2.2 V) >20 Hz to 40 Hz
| 37 ×10-6 U | Laboratory | Active
|
- (>700 mV to 2.2 V) >40 Hz to 20 kHz
| 30 ×10-6 U | Laboratory | Active
|
- (>700 mV to 2.2 V) >20 kHz to 50 kHz
| 34 ×10-6 U | Laboratory | Active
|
- (>700 mV to 2.2 V) >50 kHz to 100 kHz
| 58 ×10-6 U | Laboratory | Active
|
- (>700 mV to 2.2 V) >100 kHz to 300 kHz
| 0.17 ×10-3 U | Laboratory | Active
|
- Procedure CP-E-18 Calibration of Electrical Calibrators U = Measured Value
| - (>700 mV to 2.2 V) >300 kHz to 500 kHz
| 0.29 ×10-3 U | Laboratory | Active
|
- (>700 mV to 2.2 V) >500 kHz to 1 MHz
| 1.2 ×10-3 U | Laboratory | Active
|
- (>2.2 V to 7 V) 10 Hz to 20 Hz
| 63 ×10-6 U | Laboratory | Active
|
- (>2.2 V to 7 V) >20 Hz to 40 Hz
| 37 ×10-6 U | Laboratory | Active
|
- (>2.2 V to 7 V) >40 Hz to 20 kHz
| 28 ×10-6 U | Laboratory | Active
|
- (>2.2 V to 7 V) >20 kHz to 50 kHz
| 36 ×10-6 U | Laboratory | Active
|
- (>2.2 V to 7 V) >50 kHz to 100 kHz
| 74 ×10-6 U | Laboratory | Active
|
- (>2.2 V to 7 V) >100 kHz to 300 kHz
| 0.18 ×10-3 U | Laboratory | Active
|
- (>2.2 V to 7 V) >300 kHz to 500 kHz
| 0.45 ×10-3 U | Laboratory | Active
|
- (>2.2 V to 7 V) >500 kHz to 1 MHz
| 1.5 ×10-3 U | Laboratory | Active
|
- Procedure CP-E-18 Calibration of Electrical Calibrators U = Measured Value
| - (>7 V to 22 V) 10 Hz to 20 Hz
| 63 ×10-6 U | Laboratory | Active
|
- (>7 V to 22 V) >20 Hz to 40 Hz
| 38 ×10-6 U | Laboratory | Active
|
- (>7 V to 22 V) >40 Hz to 20 kHz
| 28 ×10-6 U | Laboratory | Active
|
- (>7 V to 22 V) >20 kHz to 50 kHz
| 36 ×10-6 U | Laboratory | Active
|
- (>7 V to 22 V) >50 kHz to 100 kHz
| 70 ×10-6 U | Laboratory | Active
|
- (>7 V to 22 V) >100 kHz to 300 kHz
| 0.19 ×10-3 U | Laboratory | Active
|
- (>7 V to 22 V) >300 kHz to 500 kHz
| 0.46 ×10-3 U | Laboratory | Active
|
- (>7 V to 22 V) >500 kHz to 1 MHz
| 1.5 ×10-3 U | Laboratory | Active
|
- (>22 V to 70 V) 10 Hz to 20 Hz
| 64 ×10-6 U + 1.6 μV | Laboratory | Active
|
- (>22 V to 70 V) >20 Hz to 40 Hz
| 40 ×10-6 U + 2.6 μV | Laboratory | Active
|
- (>22 V to 70 V) >40 Hz to 20 kHz
| 35 ×10-6 U + 2.9 μV | Laboratory | Active
|
- Procedure CP-E-18 Calibration of Electrical Calibrators U = Measured Value
| - (>22 V to 70 V) >20 kHz to 50 kHz
| 40 ×10-6 U + 2.6 μV | Laboratory | Active
|
- (>22 V to 70 V) >50 kHz to 100 kHz
| 86 ×10-6 U + 1.2 μV | Laboratory | Active
|
- (>22 V to 70 V) >100 kHz to 300 kHz
| 0.19 ×10-3 U | Laboratory | Active
|
- (>22 V to 70 V) >300 kHz to 500 kHz
| 0.50 ×10-3 U | Laboratory | Active
|
- (>22 V to 70 V) >500 kHz to 1 MHz
| 1.5 ×10-3 U | Laboratory | Active
|
- (>70 V to 220 V) 10 Hz to 20 Hz
| 66 ×10-6 U | Laboratory | Active
|
- (>70 V to 220 V) >20 Hz to 40 Hz
| 42 ×10-6 U | Laboratory | Active
|
- (>70 V to 220 V) >40 Hz to 20 kHz
| 37 ×10-6 U | Laboratory | Active
|
- (>70 V to 220 V) >20 kHz to 50 kHz
| 51 ×10-6 U | Laboratory | Active
|
- (>70 V to 220 V) >50 kHz to 100 kHz
| 89 ×10-6 U | Laboratory | Active
|
- (>220 V to 700 V) 40 Hz to 20 kHz
| 34 ×10-6 U + 30 μV | Laboratory | Active
|
- (>220 V to 700 V) >20 kHz to 50 kHz
| 0.15 ×10-3 U + 7.2 μV | Laboratory | Active
|
- (>220 V to 700 V) >50 kHz to 100 kHz
| 0.86 ×10-3 U + 1.2 μV | Laboratory | Active
|
- (>700 V to 1000 V) 40 Hz to 20 kHz
| 34 ×10-6 U + 13 μV | Laboratory | Active
|
- AC Current Calibration of measuring Instruments
| - Procedure CP-E-11 Calibration of Digital Multimeters I = Measured Value
| - (30 µA to 1 mA) 10 Hz to 20 Hz
| 75 ×10-6 I + 2.0 nA | Laboratory | Active
|
- (30 µA to 1 mA) >20 Hz to 10 kHz
| 49 ×10-6 I + 2.0 nA | Laboratory | Active
|
- (30 µA to 1 mA) >10 kHz to 30 kHz
| 48 ×10-6 I + 3.0 nA | Laboratory | Active
|
- (>1 mA to 10 mA ) 10 Hz to 20 Hz
| 73 ×10-6 I + 17 nA | Laboratory | Active
|
- (>1 mA to 10 mA ) >20 Hz to 10 kHz
| 45 ×10-6 I + 16 nA | Laboratory | Active
|
- (>1 mA to 10 mA ) >10 kHz to 30 kHz
| 45 ×10-6 I + 22 nA | Laboratory | Active
|
- (>10 mA to 50 mA ) 10 Hz to 20 Hz
| 73 ×10-6 I + 83 nA | Laboratory | Active
|
- (>10 mA to 50 mA ) >20 Hz to 10 kHz
| 47 ×10-6 I + 75 nA | Laboratory | Active
|
- (>10 mA to 50 mA ) >10 kHz to 30 kHz
| 46 ×10-6 I + 0.11 μA | Laboratory | Active
|
- (>50 mA to 500 mA ) 10 Hz to 20 Hz
| 75 ×10-6 I + 0.81 μA | Laboratory | Active
|
- (>50 mA to 500 mA ) >20 Hz to 10 kHz
| 50 ×10-6 I + 0.73 μA | Laboratory | Active
|
- (>50 mA to 500 mA ) >10 kHz to 30 kHz
| 49 ×10-6 I + 1.0 μA | Laboratory | Active
|
- (>500 mA to 1 A ) 10 Hz to 20 Hz
| 80 ×10-6 I + 1.5 μA | Laboratory | Active
|
- (>500 mA to 1 A ) >20 Hz to 10 kHz
| 57 ×10-6 I + 1.2 μA | Laboratory | Active
|
- Procedure CP-E-11 Calibration of Digital Multimeters I = Measured Value
| - (>1 A to 5 A ) 10 Hz to 20 Hz
| 83 ×10-6 I + 7.4 μA | Laboratory | Active
|
- (>1 A to 5 A ) >20 Hz to 10 kHz
| 60 ×10-6 I + 5.9 μA | Laboratory | Active
|
- (>5 A to 20 A ) 10 Hz to 20 Hz
| 0.12 ×10-3 I + 21 μA | Laboratory | Active
|
- (>5 A to 20 A ) >20 Hz to 10 kHz
| 0.11 ×10-3 I + 14 μA | Laboratory | Active
|
- (>20 A to 50 A) 20 Hz to 10 kHz
| 0.14 ×10-3 I + 27 μA | Laboratory | Active
|
- AC Current calibration of sources
| - Procedure CP-E-18 Calibration of Electrical Calibrators I = Measured Value
| - (30 µA to 1 mA) 10 Hz to 20 Hz
| 75 ×10-6 I + 2.0 nA | Laboratory | Active
|
- (30 µA to 1 mA) >20 Hz to 10 kHz
| 49 ×10-6 I + 2.0 nA | Laboratory | Active
|
- (30 µA to 1 mA) >10 kHz to 30 kHz
| 48 ×10-6 I + 3.0 nA | Laboratory | Active
|
- (>1 mA to 10 mA ) 10 Hz to 20 Hz
| 73 ×10-6 I + 17 nA | Laboratory | Active
|
- (>1 mA to 10 mA ) >20 Hz to 10 kHz
| 45 ×10-6 I + 16 nA | Laboratory | Active
|
- (>1 mA to 10 mA ) >10 kHz to 30 kHz
| 45 ×10-6 I + 22 nA | Laboratory | Active
|
- (>10 mA to 50 mA ) 10 Hz to 20 Hz
| 73 ×10-6 I + 83 nA | Laboratory | Active
|
- (>10 mA to 50 mA ) >20 Hz to 10 kHz
| 47 ×10-6 I + 75 nA | Laboratory | Active
|
- (>10 mA to 50 mA ) >10 kHz to 30 kHz
| 46 ×10-6 I + 0.11 μA | Laboratory | Active
|
- (>50 mA to 500 mA ) 10 Hz to 20 Hz
| 75 ×10-6 I + 0.83 μA | Laboratory | Active
|
- (>50 mA to 500 mA ) >20 Hz to 10 kHz
| 50 ×10-6 I + 0.75 μA | Laboratory | Active
|
- (>50 mA to 500 mA ) >10 kHz to 30 kHz
| 49 ×10-6 I + 1.1 μA | Laboratory | Active
|
- (>500 mA to 1 A ) 10 Hz to 20 Hz
| 80 ×10-6 I + 1.5 μA | Laboratory | Active
|
- (>500 mA to 1 A ) >20 Hz to 10 kHz
| 57 ×10-6 I + 1.2 μA | Laboratory | Active
|
- (>1 A to 5 A ) 10 Hz to 20 Hz
| 83 ×10-6 I + 7.5 μA | Laboratory | Active
|
- (>1 A to 5 A ) >20 Hz to 10 kHz
| 60 ×10-6 I + 6.0 μA | Laboratory | Active
|
- (>5 A to 20 A ) 10 Hz to 20 Hz
| 0.12 ×10-3 I + 21 μA | Laboratory | Active
|
- (>5 A to 20 A ) >20 Hz to 10 kHz
| 0.11 ×10-3 I + 15 μA | Laboratory | Active
|
- (>20 A to 50 A) 20 Hz to 10 kHz
| 0.14 ×10-3 I + 27 μA | Laboratory | Active
|
- DC resistance Calibration of Instruments
| - Procedure CP-E-14 Calibration of Temperature Readouts Procedure CP-E-16 Calibration of Fluke Super Thermometer Procedure CP-E-06 Calibration of 8.5 digit Digital Multimeters
| | 3.0 μΩ | Laboratory | Active
|
| 3.8 μΩ | Laboratory | Active
|
| 9.1 μΩ | Laboratory | Active
|
| 32 μΩ | Laboratory | Active
|
| 0.10 mΩ | Laboratory | Active
|
| 0.26 mΩ | Laboratory | Active
|
| 0.52 mΩ | Laboratory | Active
|
- DC Resistance calibration of Measuring Instruments
| - Procedure CP-E-11 Calibration of Digital Multimeters Procedure CP-E-24 Calibration of Process Calibrators R = Measured Value
| | 42×10-6 R + 4.1 µΩ | Laboratory | Active
|
| 41×10-6 R + 5.0 µΩ | Laboratory | Active
|
| 31×10-6 R + 18 µΩ | Laboratory | Active
|
| 29×10-6 R + 18 µΩ | Laboratory | Active
|
| 29 ×10-6 R + 0.18 mΩ | Laboratory | Active
|
| 29 ×10-6 R + 0.18 mΩ | Laboratory | Active
|
- Procedure CP-E-11 Calibration of Digital Multimeters Procedure CP-E-24 Calibration of Process Calibrators R = Measured Value
| | 29 ×10-6 R + 1.7 mΩ | Laboratory | Active
|
| 29 ×10-6 R + 1.4 mΩ | Laboratory | Active
|
| 29 ×10-6 R + 17 mΩ | Laboratory | Active
|
| 30 ×10-6 R + 15 mΩ | Laboratory | Active
|
| 34 ×10-6 R + 25 mΩ | Laboratory | Active
|
| 34 ×10-6 R + 25 mΩ | Laboratory | Active
|
| 62 ×10-6 R + 2.3 Ω | Laboratory | Active
|
| 0.13 ×10-3 R + 0.92 Ω | Laboratory | Active
|
| 0.16 ×10-3 R + 9.0 kΩ | Laboratory | Active
|
| 0.48 ×10-3 R + 4.2 kΩ | Laboratory | Active
|
| 3.0 ×10-3 R + 20 kΩ | Laboratory | Active
|
| 15 ×10-3 R + 2.1 kΩ | Laboratory | Active
|
- DC Resistance calibration of sources
| - Procedure CP-E-18 Calibration of Electrical Calibrators Procedure CP-E-23 Calibration of Resistor Decades Procedure CP-E-24 Calibration of Process Calibrators R = Measured Value
| | 13 ×10-6 R + 4.0 μΩ | Laboratory | Active
|
| 7.9 ×10-6 R + 14 μΩ | Laboratory | Active
|
| 7.4 ×10-6 R + 49 μΩ | Laboratory | Active
|
| 7.2 ×10-6 R + 0.50 mΩ | Laboratory | Active
|
| 7.3 ×10-6 R + 4.9 mΩ | Laboratory | Active
|
| 7.6 ×10-6 R + 48 mΩ | Laboratory | Active
|
| 8.4 ×10-6 R + 85 mΩ | Laboratory | Active
|
| 12 ×10-6 R + 8.3 Ω | Laboratory | Active
|
| 46 ×10-6 R + 9.8 kΩ | Laboratory | Active
|
| 68 ×10-6 R + 94 kΩ | Laboratory | Active
|
| 0.56 ×10-3 R +0.96 MΩ | Laboratory | Active
|
- DC Current Calibration of Measuring Instruments
| - Procedure CP-E-11 Calibration of Digital Multimeters Procedure CP-E-24 Calibration of Process Calibrators I = Measured Value
| | 4.0 ×10-6 I + 49 pA | Laboratory | Active
|
| 4.0 ×10-6 I + 0.49 nA | Laboratory | Active
|
| 4.0 ×10-6 I + 4.9 nA | Laboratory | Active
|
| 2.3×10-6 I + 0.65 μA | Laboratory | Active
|
| 35 ×10-6 I + 4.2 μA | Laboratory | Active
|
| 38 ×10-6 I + 0.88 μA | Laboratory | Active
|
| 38×10-6 I + 16 μA | Laboratory | Active
|
- DC Current Calibration of sources
| - Procedure CP-E-18 Calibration of Electrical Calibrators Procedure CP-E-24 Calibration of Process Calibrators I = Measured Value
| | 4.0 ×10-6 I + 49 pA | Laboratory | Active
|
| 4.0 ×10-6 I + 0.49 nA | Laboratory | Active
|
| 4.0 ×10-6 I + 4.9 nA | Laboratory | Active
|
| 2.3×10-6 I + 0.65 μA | Laboratory | Active
|
| 35 ×10-6 I + 4.2 μA | Laboratory | Active
|
| 38 ×10-6 I + 0.88 μA | Laboratory | Active
|
| 38×10-6 I + 16 μA | Laboratory | Active
|
- Procedure CP-E-22 Calibration of Current Source I = measured current value
| | 17 ×10-6 I | Laboratory | Active
|
| 20 ×10-6 I | Laboratory | Active
|
- Temperature Calibration of measuring instruments by simulation
| - Procedure CP-E-14 Calibration of Temperature Readouts Procedure CP-E-18 Calibration of Electrical Calibrators Procedure CP-E-24 Calibration of Process Calibrators
| - (RTD: (PT100 (385)) -270 °C to 860 °C
| 0.010 °C | Laboratory | Active
|
- (THERMOCOUPLE: (Type J)) -200 °C to <-100 °C
| 0.15 °C | Laboratory | Active
|
- (THERMOCOUPLE: (Type J)) -100 °C to 1000 °C
| 0.14 °C | Laboratory | Active
|
- (Type K) -200 °C to <-100 °C
| 0.16 °C | Laboratory | Active
|
- (Type K) -100 °C to 1000 °C
| 0.13 °C | Laboratory | Active
|
- Procedure CP-E-14 Calibration of Temperature Readouts Procedure CP-E-18 Calibration of Electrical Calibrators Procedure CP-E-24 Calibration of Process Calibrators
| - (THERMOCOUPLE: (Type N) -200 °C to <-100 °C
| 0.20 °C | Laboratory | Active
|
- (THERMOCOUPLE: (Type N) -100 °C to 1300 °C
| 0.15 °C | Laboratory | Active
|
| 0.33 °C | Laboratory | Active
|
- (Type R) 100 °C to <500 °C
| 0.23 °C | Laboratory | Active
|
- (Type R) 500 °C to <1000 °C
| 0.19 °C | Laboratory | Active
|
- (Type R) 1000 °C to 1700 °C
| 0.18 °C | Laboratory | Active
|
| 0.33 °C | Laboratory | Active
|
- (Type S) 100 °C to <500 °C
| 0.25 °C | Laboratory | Active
|
- (Type S) 500 °C to <1000 °C
| 0.20 °C | Laboratory | Active
|
- (Type S) 1000 °C to 1700 °C
| 0.19 °C | Laboratory | Active
|
- (THERMOCOUPLE: (Type T) -200 °C to <-100 °C
| 0.17 °C | Laboratory | Active
|
- (THERMOCOUPLE: (Type T) -100 °C to <0 °C
| 0.15 °C | Laboratory | Active
|
- (THERMOCOUPLE: (Type T) 0 °C to 400 °C
| 0.14 °C | Laboratory | Active
|
- Temperature Calibration of simulators
| - Procedure CP-E-18 Calibration of Electrical Calibrators Procedure CP-E-24 Calibration of Process Calibrators
| - (RTD: (PT100 (385)) -270 °C to 860 °C
| 0.014 °C | Laboratory | Active
|
- (THERMOCOUPLE: (Type J) -200 °C to <-100 °C
| 0.11 °C | Laboratory | Active
|
- (THERMOCOUPLE: (Type J) -100 °C to <0 °C
| 0.091 °C | Laboratory | Active
|
- (THERMOCOUPLE: (Type J) 0 °C to 1200 °C
| 0.089 °C | Laboratory | Active
|
- Procedure CP-E-18 Calibration of Electrical Calibrators Procedure CP-E-24 Calibration of Process Calibrators
| - (THERMOCOUPLE: (Type K) -200 °C to <-100 °C
| 0.13 °C | Laboratory | Active
|
- (THERMOCOUPLE: (Type K) -100 °C to <0 °C
| 0.096 °C | Laboratory | Active
|
- (THERMOCOUPLE: (Type K) 0 °C to 1250 °C
| 0.093 °C | Laboratory | Active
|
- (Type N) -200 °C to <-100 °C
| 0.17 °C | Laboratory | Active
|
- (Type N) -100 °C to <100 °C
| 0.11 °C | Laboratory | Active
|
- (Type N) 100 °C to 1300 °C
| 0.096 °C | Laboratory | Active
|
| 0.32 °C | Laboratory | Active
|
- (Type R) 100 °C to <500 °C
| 0.20 °C | Laboratory | Active
|
- (Type R) 500 °C to <1000 °C
| 0.16 °C | Laboratory | Active
|
- (Type R) 1000 °C to 1700 °C
| 0.14 °C | Laboratory | Active
|
- (THERMOCOUPLE: (Type S) 0 °C to <100 °C
| 0.30 °C | Laboratory | Active
|
- (THERMOCOUPLE: (Type S) 100 °C to <500 °C
| 0.22 °C | Laboratory | Active
|
- (THERMOCOUPLE: (Type S) 500 °C to <1000 °C
| 0.17 °C | Laboratory | Active
|
- (THERMOCOUPLE: (Type S) 1000 °C to 1700 °C
| 0.15 °C | Laboratory | Active
|
- (Type T) -200 °C to <-100 °C
| 0.092 °C | Laboratory | Active
|
- (Type T) -100 °C to <0 °C
| 0.097 °C | Laboratory | Active
|
| 0.093 °C | Laboratory | Active
|
- (Type T) 100 °C to 400 °C
| 0.089 °C | Laboratory | Active
|
- CAPACITANCE Calibration of Measuring Instruments
| - Procedure CP-E-11 Calibration of Digital Multimeters C = Measured Value
| | 5.0 ×10-3 C + 11 pF | Laboratory | Active
|
| 2.5 ×10-3 C + 11 pF | Laboratory | Active
|
| 2.5 ×10-3 C + 0.11 nF | Laboratory | Active
|
| 2.5 ×10-3 C + 0.11 nF | Laboratory | Active
|
| 2.5 ×10-3 C + 0.31 nF | Laboratory | Active
|
| 2.5 ×10-3 C + 1.1 nF | Laboratory | Active
|
| 2.5 ×10-3 C + 3.1 nF | Laboratory | Active
|
| 2.4 ×10-3 C + 14 nF | Laboratory | Active
|
| 3.9 ×10-3 C +38 nF | Laboratory | Active
|
| 4.3 ×10-3 C + 0.14 µF | Laboratory | Active
|
| 4.3 ×10-3 C + 0.41 µF | Laboratory | Active
|
| 4.4 ×10-3 C + 1.2 µF | Laboratory | Active
|
| 4.5 ×10-3 C + 3.1 µF | Laboratory | Active
|
| 4.5 ×10-3 C + 11 µF | Laboratory | Active
|
| 7.5 ×10-3 C + 31 µF | Laboratory | Active
|
| 11 ×10-3 C + 12 µF | Laboratory | Active
|
- Capacitance calibration of sources
| - Procedure CP-E-18 Calibration of Electrical Calibrators Procedure CP-E-28 Calibration of Capacitors and Inductors
| | 1.4 pF | Laboratory | Active
|
| 2.9 pF | Laboratory | Active
|
| 7.7 pF | Laboratory | Active
|
| 25 pF | Laboratory | Active
|
| 76 pF | Laboratory | Active
|
| 0.26 nF | Laboratory | Active
|
| 0.78 nF | Laboratory | Active
|
| 11 nF | Laboratory | Active
|
| 31 nF | Laboratory | Active
|
| 0.12 µF | Laboratory | Active
|
| 0.37 µF | Laboratory | Active
|
| 0.87 µF | Laboratory | Active
|
| 0.87 µF | Laboratory | Active
|
| 2.9 µF | Laboratory | Active
|
| 9.5 µF | Laboratory | Active
|
| 33 µF | Laboratory | Active
|
| - Procedure CP-E-28 Calibration of Capacitors and Inductors Substitution method at 1 kHz C = Measured Value
| | 20 ×10-6 C | Laboratory | Active
|
| 20 ×10-6 C | Laboratory | Active
|
| 20 ×10-6 C | Laboratory | Active
|
| - Procedure CP-E-28 Calibration of Capacitors and Inductors Substitution method at 1 kHz L= Measured Value
| | 0.75 ×10-3 L | Laboratory | Active
|
| 0.14 ×10-3 L | Laboratory | Active
|
| 0.26 ×10-3 L | Laboratory | Active
|
| 0.27 ×10-3 L | Laboratory | Active
|
| 0.26 ×10-3 L | Laboratory | Active
|
- Inductance Calibration of Sources
| - Procedure CP-E-28 Calibration of Capacitors and Inductors L= Measured Value
| | 1.1 ×10-3 L | Laboratory | Active
|
| 0.80 ×10-3 L | Laboratory | Active
|
- AC power Calibration of power meters
| - Procedure CP-E-30 Primary Power Measurements
| | Active power | Laboratory | Active
|
| 25 μW/VA | Laboratory | Active
|
| Reactive power | Laboratory | Active
|
| 40 μvar/VA | Laboratory | Active
|
- AC power Calibration of phantom power sources
| | Active Power | Laboratory | Active
|
| 25 μW/ VA | Laboratory | Active
|
| Reactive Power | Laboratory | Active
|
| 40 μvar/ VA | Laboratory | Active
|
- AC energy Calibration of energy meters
| | Active Power | Laboratory | Active
|
| 25 μWh/ VAh | Laboratory | Active
|
| Reactive Power | Laboratory | Active
|
| 40 μvarh/ VAh | Laboratory | Active
|
- AC energy Calibration of phantom energy sources
| | Active Power | Laboratory | Active
|
| 25 μWh/ VAh | Laboratory | Active
|
| Reactive Power | Laboratory | Active
|
| 40 μvarh/ VAh | Laboratory | Active
|
- AC energy Calibration of energy meters
| - Procedure CP-E-31 Power Measurements class 0.1 and above
| | Active energy | Laboratory | Active
|
| 260 μWh/VAh | Laboratory | Active
|
| Reactive energy | Laboratory | Active
|
| 270 μvarh/Vah | Laboratory | Active
|
- AC Current Ratio Calibration of Isolating Current Transformer
| - Procedure CP-E-34 Calibration of Isolating Current Transformer
| | Ratio Error Uncertainty | Laboratory | Active
|
| 0.18 ×10-3 | Laboratory | Active
|
| Defect Angle Uncertainty | Laboratory | Active
|
| 0.11 ° | Laboratory | Active
|
| Density |
- Solid Density Standard at 20°C Mass: 1 kg
| - CP-V-05 “Solid density by Hydrostatic weighing” Hydrostatic weighing (comparison to reference silicon sphere SP-1)
| | 1.5 kg/m3 | Laboratory | Active
|
- Density of solid at 20°C Mass: 20g to 30g
| - CP-V-05 “Solid density by Hydrostatic weighing” Hydrostatic weighing with use of volume comparator
| | 1 kg/ m3 | Laboratory | Active
|
- Density of solid at 20°C Mass: 1g to 1kg Density: 7900 kg/m3 to 8400 kg/m3
| | 60 kg/m3 | Laboratory | Active
|
| 30 kg/m3 | Laboratory | Active
|
| 15 kg/m3 | Laboratory | Active
|
| 8 kg/m3 | Laboratory | Active
|
| 5 kg/m3 | Laboratory | Active
|
| 3 kg/m3 | Laboratory | Active
|
| 2.5 kg/m3 | Laboratory | Active
|
| 2 kg/m3 | Laboratory | Active
|
| 2 kg/m3 | Laboratory | Active
|
| 1.5 kg/m3 | Laboratory | Active
|
- Density of Liquid at 20°C
| - CP-V-04 Hydrostatic weighing with use of glass sinker of appr. . ca. 25g mass
| | 0.86 kg/m3 to 1.3 kg/m3 | Laboratory | Active
|
| Volume |
- Volume of Liquids Piston operated volumetric apparatus (pipettes, dispensers)
| - CP-V-01 “Gravimetric Calibration of piston operated pipettes” Fixed and variable volume single and multi-channel Manual or automatic piston operated pipettes using gravimetric method: - 1 volume (fixed volume pipettes) - 3 volumes (variable volume pip
| | 0.024 µl | Laboratory | Active
|
| 0.028 µl | Laboratory | Active
|
| 0.046 µl | Laboratory | Active
|
| 0.083 µl | Laboratory | Active
|
| 0.17 µl | Laboratory | Active
|
| 0.41 µl | Laboratory | Active
|
| 2.1 µl | Laboratory | Active
|
| 5 µl | Laboratory | Active
|
| 8 µl | Laboratory | Active
|
| 17 µl | Laboratory | Active
|
- Volumetric glassware One-mark flasks
| - CP-V-02 “Gravimetric Calibration of Volumetric Glassware”
| | 0.023 ml | Laboratory | Active
|
| 0.033 ml | Laboratory | Active
|
| 0.047 ml | Laboratory | Active
|
| 0.064 ml | Laboratory | Active
|
| 0.087 ml | Laboratory | Active
|
| 0.13 ml | Laboratory | Active
|
| 0.19 ml | Laboratory | Active
|
- Volumetric glassware Graduated measuring cylinders
| | 0.070 ml | Laboratory | Active
|
| 0.12 ml | Laboratory | Active
|
| 0.21 ml | Laboratory | Active
|
| 0.38 ml | Laboratory | Active
|
| 0.60 ml | Laboratory | Active
|
| 0.84 ml | Laboratory | Active
|
| 1.5 ml | Laboratory | Active
|
| 2.5 ml | Laboratory | Active
|
- Volumetric glassware Pipettes
| | 0.0060 ml | Laboratory | Active
|
| 0.0060 ml | Laboratory | Active
|
| 0.012 ml | Laboratory | Active
|
| 0.018 ml | Laboratory | Active
|
| 0.040 ml | Laboratory | Active
|
- Volumetric glassware Burettes
| | 0.020 ml | Laboratory | Active
|
| 0.020 ml | Laboratory | Active
|
| 0.040 ml | Laboratory | Active
|
| 0.070 ml | Laboratory | Active
|
| - CP-V-03 “Gravimetric Calibration of Prover Vessels”
| | 0.001 | Laboratory | Active
|
| Dimensions |
- Gauge Block (mm)(steel, ceramic, Tungsten) carbide)
| - Measurement of central length by interferometry. Measured twice, wrung to a platen by each of the two measuring faces in turn, and the mean of these two measurements stated on the certificate. Procedure used: EMI Procedure no.: CP-D-09 ISO 3650:1998
| - 0.5 mm to 100 mm, Grade K and Grade 0
| Q[25 nm, 0.7×10-6 L] | Laboratory | Active
|
- Long Gauge Block (mm) (steel, ceramic, Tungsten)
| - Measurement of central length by interferometry. Measured twice, wrung to a platen by each of the two measuring faces in turn, and the mean of these two measurements stated on the certificate. Procedure used: EMI Procedure no.: CP-D-09 ISO 3650:1998
| - 100 mm to 300 mm Grade K and Grade 0
| Q[37 nm, 0.7×10-6 L] | Laboratory | Active
|
| - Measurement of central length by mechanical comparison. Procedure used: EMI procedure no.: CP-D-03 ISO 3650:1998
| | Q[80 nm, 1.1×10-6 L] | Laboratory | Active
|
| Q[80 nm, 1.93×10-6 L] | Laboratory | Active
|
| - Measurement of central length by mechanical comparison to same nominal size long gauge blocks using universal length measuring machine Procedure used: EMI procedure no.: CP-D-06 ISO 3650:1998
| | Q[0.16 μm, 1.9×10-6 L] | Laboratory | Active
|
| - For determining error of indicated displacement Mechanical comparison to gauge block couples Procedure used: EMI procedure no.: CP-D-12 EURAMET cg-2 Version 2.0 (03/2011) (Previously EA-10/02)
| | 0.05 μm | Laboratory | Active
|
- 1-D measuring Machine (Universal Length Measuring Machine)
| - For determining error of indicated size/displacement Mechanical comparison to gauge block Procedure used: EMI procedure no.: CP-D-13
| | Q[0.062 μm, 1.3×10-6 L] | Laboratory | Active
|
- Height Gauges (analoges, digitals)
| - For determining error of indicated vertical size Comparison with calliper checker Procedure used: EMI Procedure no.: CP-D-05 ISO 13225:2012
| - upto 600 mm, resolution 0.01 mm
| (0.02 mm + 1×10-5L) | Laboratory | Active
|
| - Measurement of included angle by comparison to primary encoder. Procedure used: EMI Procedure no.: CP-D-15
| | 0.6" | Laboratory | Active
|
- Angle Indicating Instruments
| - For determining error of indicated inclination angle Comparison to primary encoder in vertical orientation Procedure used: EMI procedure no.: CP-D-16
| - upto 90º, resolution 0.01º
| 0.01° | Laboratory | Active
|
| - For determining error of indicated displacement, Comparison with universal length measuring machine Procedure used: EMI procedure no.: CP-D-02 ISO 463:2006
| - up to 50 mm, resolution 0.001 mm
| 2µm | Laboratory | Active
|
- 50 mm to 100mm, resolution 0.001 mm
| 3µm | Laboratory | Active
|
| - For determining error of indicated size Comparison with reference gauge blocks Comparison with universal length measuring machine. Procedure used: EMI procedure no.: CP-D-01 ISO 3611:2010
| - 0 mm to 25mm, resolution 0.001 mm
| 2µm | Laboratory | Active
|
- 25 mm to 75mm resolution 0.001 mm
| 2µm | Laboratory | Active
|
- 75 mm to 175mm resolution 0.001 mm
| 3µm | Laboratory | Active
|
- External Cylinder, Plain Plug Gauges (parallel) and Pin Gauges
| - Comparison with reference gauge block using universal length measuring machine. Procedure used: EMI Procedure no.: CP-D-07 EURAMET cg-6 Version 2.0 (03/2011)
| | 0.8 µm | Laboratory | Active
|
- Internall Cylinder, Plain Ring Gauges (parallel)
| - Comparison with reference ring gauge using universal length measuring machine. Procedure used: EMI Procedure no.: CP-D-08 EURAMET cg-6 Version 2.0 (03/2011)
| | 0.8 µm | Laboratory | Active
|
- Calipers (digital, vernier)
| - For determining error of indicated size Comparison with calliper checker and gauge blocks (for callipers with vernier scale). Procedure used: EMI procedure no.: CP-D-04 ISO 13385-1:2019
| - up to 600 mm resolution 0.01 mm
| (0.02 mm + 1.2×10-5 L) | Laboratory | Active
|
| Force |
- Force / Force Proving Instruments (tension and compression mode)
| - Calibration of force proving instruments in accordance with ISO 376:2011 increasing and decreasing forces
| | 0.05% of indicated value | Laboratory | Active
|
| 0,1 % of indicated value | Laboratory | Active
|
| Pressure |
- Pneumatic Negative Gauge Analogue and digital pressure gauges
| - CP-P-01 SOP based on DKD-R 6-1 and Euramet cg17
| | 3 Pa + 1.6x10-3*p | Laboratory | Active
|
- Pneumatic Differential Pressure Analogue and digital pressure gauges
| | 3 Pa + 1.6x10-3*p | Laboratory | Active
|
- Pneumatic Gauge and Absolute Pressure Analogue and digital pressure gauges
| | 2 Pa+2.0x10-5*p | 8.024 | Active
|
| 3.5 Pa+2.5x10-5*p | Laboratory | Active
|
| 10 Pa+3.0x10-5*p | Laboratory | Active
|
- Hydraulic Gauge Pressure Analogue and digital pressure gauges
| | 0.10 kPa+4.2x10-5*p | Laboratory | Active
|
| 1,610-4*p | Laboratory | Active
|