Type of Activity |
Test Materials / Products |
Test Name |
Test Method |
Status |
CM |
| | - Methods of test for soils for civil engineering purposes - Classification tests and determination of geotechnical properties (Determination of particle size distribution)
| BS 1377 Part 2 Clause 10 BS EN 17892 Part 4 Clause 5.2 | Active
|
- Methods of test for soils for civil engineering purposes Part 2: Classification tests and determination of geotechnical properties Caluse 11.5: Compaction method using 4.5 kg rammer with 1 L mould 25 Figure 7 — 4.5 kg rammer for compaction test Caluse 11.6: Method using 4.5 kg rammer with CBR mould
| BS 1377 Part 2 Clause 11.5 & Clause 11.6 | Active
|
- Methods of test for soils for civil engineering purposes Part 2: Classification tests and determination of geotechnical properties Calause 15: Determination of California Bearing Ratio (CBR)
| BS 1377 Part 2 Clause 15 | Active
|
- Methods for test for soils for civil engineering purposes. In-situ tests (Sand replacement method suitable for fine, medium and coarse grained soils (large pouring cylinder method))
| BS 1377 Part 9 Clause 2.2 | Active
|
- Standard Test Method for Particle-Size Analysis of Soils
| ASTM D422 | Active
|
- Methods of test for soils for civil engineering purposes Part 2: Classification tests and determination of geotechnical properties Clause 11.3: v Clause 11.4: Compaction method using 2.5 kg rammer with CBR mould
| BS 1377 Part 2 Clause 11.3 & Clause 11.4 | Active
|
- Standard Methods for Liquid Limit, Plastic Limit, and Plasticity Index of Soils
| ASTM D4318 | Active
|
- Methods of test for soils for civil engineering purposes Part 2: Classification tests and determination of geotechnical properties Clause 5: Determination of liquid limit.
| BS 1377 Part 2 Clause 5 ISO 17892 Part 12+A1 Clause 5.3 & 5.4 | Active
|
- Methods of test for soils for civil engineering purposes Part 2: Classification tests and determination of geotechnical properties Clause 6: Determination of plastic limit and plasticity index
| BS 1377-2 Clause 6 ISO 17892-12+A1 Clause 5.5 & Clause 6.5 | Active
|
- Methods of test for soils for civil engineering purposes Part 2: Classification tests and determination of geotechnical properties Clause 4: Determination of water content
| BS 1377 Part 2 Clause 4.1 BS EN 17892 Part 1+A1 | Active
|
| - Testing hardened concrete. Depth of penetration of water under pressure
| BS EN 12390 Part 8 | Active
|
- Testing concrete Method for determination of compressive strength of concrete cubes
| BS 1881 Part 116 | Active
|
- Recommendations for the determination of the initial surface absorption of concrete
| BS 1881 Part 208 | Active
|
- Determination of water absorption on hardened concrete
| BS 1881 Part 122 | Active
|
- Testing concrete Part 111: Method of normal curing of test specimens (20°C method)
| BS 1881 Part 111 | Active
|
- Testing concrete Part 114: Methods for determination of density of hardened concrete
| BS 1881 Part 114 | Active
|
- Testing hardened concrete Part 2: Making and curing specimens for strength tests
| BS EN 12390 Part 2 | Active
|
- Standard Practice for Making and Curing Concrete Test Specimens in the Laboratory
| ASTM C192 / C192M | Active
|
- Testing hardened concrete Part 1: Shape, dimensions and other requirements for specimens and moulds
| BS EN 12390 Part 1 | Active
|
- Testing Hardened Concrete Part 3: Compressive strength of test specimens
| BS EN 12390 Part 3 | Active
|
- Testing hardened concrete Part 5: Flexural strength of test specimens
| BS EN 12390 Part 5 | Active
|
- Testing hardened concrete Part 7: Density of hardened concrete
| BS EN 12390 Part 7 | Active
|
- Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
| ASTM C39 / C39M | Active
|
- Testing concrete in structures. Cored specimens Part 1: Taking, examining and testing in compression
| BS EN 12504 Part 1 | Active
|
| - Standard Test Method for Low Strain Impact Integrity Testing of Deep Foundations
| ASTM D5882 | Active
|
| - Standard Test Method for Static Modulus of Elasticity and Poisson’s Ratio of Concrete in Compression
| ASTM C469/C469M | Active
|
| - Testing concrete Part 102: Method for determination of slump
| BS 1881 Part 102 | Active
|
- Testing fresh concrete Part 2: Slump test
| BS EN 12350 Part 2 | Active
|
- Testing concrete Part 106: Methods for determination of air content of fresh concrete
| BS 1881-106:1983 | Active
|
- Testing fresh concrete Part 7: Air content. Pressure methods
| BS EN 12350 Part 7 | Active
|
- Testing fresh concrete Part 1: Sampling
| BS EN 12350 Part 1 | Active
|
- Standard practice for Sampling of Freshly mixed Concrete
| ASTM C172 | Active
|
- Testing fresh concrete Part 6: Density
| BS EN 12350 Part 6 | Active
|
- Standard Test Method for Density (Unit Weight), Yield, and Air Content (Gravimetric) of Concrete
| ASTM C138 / C138M | Active
|
- Standard Test Method for Bleeding of Concrete
| ASTM C232 / C232M | Active
|
- Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
| ASTM C1064/ C1064M | Active
|
- Testing fresh concrete Part 5: Flow table test
| BS EN 12350 Part 5 | Active
|
- Standard Test Method for Slump Flow of Self-Consolidating Concrete
| ASTM C1611 / C1611M | Active
|
- Testing fresh concrete Part 4: Degree of compactability
| BS EN 12350 Part 4 | Active
|
- Testing concrete Part 108: Method for making test cubes from fresh concrete
| BS 1881 Part 108 | Active
|
| - Testing Aggregates Part 2. Methods of determination of density - for aggregates all larger than 10mm
| BS 812 Part 2 Clause 5.3 | Active
|
- Standard Practice for Sampling Aggregates
| ASTM D75/75M | Active
|
- Testing aggregate Part 102: Methods for Sampling Tests for general properties of aggregates
| BS 812 Part 102 | Active
|
- Tests for general properties of aggregates Part 1: Methods for sampling
| BS EN 932 Part 1 | Active
|
- Testing aggregates Part 2: Methods for determination of density Clause 5.4: Particle density and water absorption of aggregate between 40mm and 5mm
| BS 812 Part 2 Clause 5.4 | Active
|
- Testing aggregates Part 2: Methods for determination of density Clause 5.5: Particle density and water absorption (10mm aggregate & smaller)
| BS 812 Part 2 Clause 5.5 | Active
|
- Standard Test Method for Density, Relative Density (Specific Gravity), and Absorption of Coarse Aggregate
| ASTM C127 | Active
|
- Standard Test Method for Relative Density (Specific Gravity) and Absorption of Fine Aggregate
| ASTM C128 | Active
|
- Tests for geometrical properties of aggregates Part 1: Determination of particle size distribution. Sieving method
| BS EN 933 Part 1 | Active
|
- Tests for mechanical and physical properties of aggregates Part 6: Determination of particle density and water absorption - wire basket method for aggregate particles passing the 63mm test sieve and retained on the 31.5mm test sieve
| BS EN 1097 Part 6 Clause7 | Active
|
- Tests for mechanical and physical properties of aggregates Part 6: Determination of Particle Density and Water Absorption- pyknometer method for aggregate particles passing the 31.5mm test sieve and retained on the 4mm test sieve
| BS EN 1097 Part 6 Clause 8 | Active
|
- Tests for mechanical and physical properties of aggregates Part 6: Determination of Particle Density and Water Absorption- pyknometer method for aggregate particles passing the 4mm test sieve and retained on the 0.063mm test sieve
| BS EN 1097 Part 6 Clause 9 | Active
|
- Testing aggregates Part 109: Methods for determination of moisture content (drying oven)
| BS 812 Part 109 | Active
|
- Testing aggregates Part 103: Method for determination of particle size distribution Section 103.1 Sieve tests
| BS 812 Part 103 Section 103.1 | Active
|
- Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
| ASTM C136/ C136M | Active
|
- Standard Test Method for Materials Finer than 75-µm (No. 200) Sieve in Mineral Aggregates by Washing
| ASTM C117 | Active
|
- Testing Aggregates Part 110: Methods for determination of aggregate crushing value (ACV)
| BS 812 Part 110 | Active
|
- Testing Aggregates Part 111: Determination of ten percent fines value (TFV)
| BS 812 Part 111 | Active
|
- Testing Aggregates Part 112: Methods for determination of aggregate impact value (AIV)
| BS 812 Part 112 | Active
|
- Tests for mechanical and physical properties of aggregates Part 5: Determination of the water content by drying in a ventilated oven
| BS EN 1097 Part 5 | Active
|
- Standard Test Method for Total Evaporable Moisture Content of Aggregate by Drying
| ASTM C566 | Active
|
- Standard Test Method for Sand Equivalent Value of Soils and Fine Aggregate
| ASTM D2419 | Active
|
- Tests for geometrical properties of aggregates Part 8: Assessment of fines - sand equivalent test
| BS EN 933 Part 8 + A1 | Active
|
- Tests for geometrical properties of aggregates Part 3: Determination of particle shape - Flakiness index
| BS EN 933 Part 3 | Active
|
- Testing aggregates Part 105: Methods for determination of particle shape Section 105.1 Flakiness index
| BS 812 Part 105 Section 105.1 | Active
|
- Tests for geometrical properties of aggregates Part 4: Determination of particle shape - Shape index
| BS EN 933 Part 4 | Active
|
- Testing aggregates Part 105: Methods for determination of particle shape Section 105.2: Elongation index of coarse aggregate
| BS 812 Part 105 Section 105.2 | Active
|
- Standard Test Method for Flat Particles, Elongated particles or Flat and Elongated Particles in Coarse Aggregate
| ASTM D4791 | Active
|
- Standard Test Method for Determining the Percentage of Fractured Particles in Coarse Aggregate
| ASTM D5821 | Active
|
- Tests for geometrical properties of aggregates Part 5: Determination of percentage of crushed and broken surfaces in coarse aggregate particles
| BS EN 933 Part 5 | Active
|
- Testing aggregates Part 106: Method for determination of shell content in coarse aggregate
| BS 812 Part 106 | Active
|
- Tests for geometrical properties of aggregates Part 7: Determination of shells content - percentage of shells in coarse aggregate
| BS EN 933 Part 7 | Active
|
- Standard Test Method for Clay Lumps and Friable Particles in Aggregates
| ASTM C142/C142M | Active
|
- Standard Methods for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine
| ASTM C131/C131M | Active
|
- Standard Methods for Resistance to Degradation of Large-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine
| ASTM C535 | Active
|
- Test for mechanical and physical properties of aggregates Part 2: Methods for determination of resistance o fragmentation
| BS EN 1097 Part 2 | Active
|
- Standard Method of Test for Uncompacted Void Content of Fine Aggregate
| AASHTO Designation: T304-11 | Active
|
- Standard Test Methods for Uncompacted Void Content of Fine Aggregate (as Influenced by Particle Shape, Surface Texture and Grading)
| ASTM C1252 | Active
|
- Standard Practice for Reducing Samples of Aggregate to Testing Size
| ASTM C702/C702M | Active
|
- Test for general properties of aggregates Part 2: Methods for reducing laboratory samples
| BS EN 932 Part 2 | Active
|
- Standard Test Method for Soundness of Aggregates by Use of Sodium Sulfate or Magnesium Sulfate
| ASTM C88 | Active
|
- Tests for thermal and weathering properties of aggregates Part 2: Magnesium Sulfate Test
| BS EN 1367 Part 2 | Active
|
| - Measurement of dimension of pre-cast concrete Masonry Blocks
| BS 6073 Part 1 Appendix A | Active
|
- Determination of Compressive Strength of pre-cast Masonry Blocks
| BS 6073 Part 2 Appendix B | Active
|
- Precast concrete paving blocks Part 1: Specification for paving blocks- Determination of compressive strength
| BS 6717 Part 1 Annex B | Active
|
- Precast concrete paving blocks Part 1: Specification for paving blocks- Measurement of dimensions and plan area
| BS 6717 Part 1 Annex A | Active
|
| - Heat of Hydration (Concrete Temp Monitoring)
| EL-M-OP-CMT-MD009 | Active
|
| | EL-M-OP-CMT-MD008 | Active
|
| - Compressive, Dimension and Net and gross density (excpet for natural stone)
| BS EN 772-1+A1 BS EN 772-16 BS EN 772-13 | Active
|
| | - Standard Test Methods for pH of Water
| ASTM D1293 | Active
|
- Mixing Water For Concrete
| - Mixing water for concrete. Specification for sampling, testing and assessing the suitability of water, including water recovered from processes in the concrete industry, as mixing water for concrete.
| BS EN 1008 | Active
|
- Standard Test Methods for Chloride Ion In Water
| ASTM D512 | Active
|
| - Testing concrete. Methods for analysis of hardened concrete (Determination of Chloride content in hardened concrete)
| BS 1881 Part 124 Clause 10.2 | Active
|
- Testing concrete. Methods for analysis of hardened concrete (Determination of Sulphate content in hardened concrete)
| BS 1881 Part 124 Clause 10.3 | Active
|
- Standard Test Method for Electrical Indication of Concrete's Ability to Resist Chloride Ion Penetration
| ASTM C1202 | Active
|
- Electrical indication of concrete's ability to resist chloride ion penetration
| AASHTO T 277 | Active
|
| NT Build 492 | Active
|
| - Methods of test for soils for civil engineering purposes Part 3: Chemical and electro-chemical tests Determination of the chloride content- Acid Soluble Chloride Content of Soil
| BS 1377 Part 3 Clause 9.3 | Active
|
- Methods of test for soils for civil engineering purposes Part 3: Chemical and electro-chemical tests Determination of the sulphate content of soil- Acid Soluble Sulphate Content of Soil
| BS 1377 Part 3 Clause 7.9 | Active
|
- Methods of test for soils for civil engineering purposes. Chemical and electro-chemical testing. Determination of the mass loss on ignition
| BS 1377 Part 3 Clause 6 | Active
|
- Methods of test for soils for civil engineering purposes Part 3: Chemical and electro chemical tests- Determination of the organic matter content Clause 4: Determination of the organic matter content
| BS 1377 Part 3 Clause 4 | Active
|
- Methods of test for soils for civil engineering purposes. Part 3: Chemical and electro-chemical testing. Determination of total organic carbon
| BS 1377 Part 3 Clause 5 | Active
|
- Methods of test for Soils for civil engineering purposes Part 3: Chemical and electro-chemical tests Clause 6.3: Determination of the carbonate content- Rapid titration method
| BS 1377 Part 3 Clause 6.3 | Active
|
- Methods of test for soils for civil engineering purposes. Chemical and electro-chemical testing. Determination of water-soluble chloride content
| BS 1377 Part 3 Clause 9.2 | Active
|
- Methods of test for soils for civil engineering purposes Part 3: Chemical and electro-chemical tests Determination of the pH value
| BS 1377-3 Clause 12 | Active
|
- Methods of test for soils for civil engineering purposes Part 3: Chemical and electro-chemical tests Determination of Resistivity- Measurement of resistivity: Wenner probe method
| BS 1377-3 Clause 13 | Active
|
| EMT-M-OP-CH-DXB-MD112A | Active
|
| - Tests for chemical properties of aggregates Part 1: Chemical analysis
| BS EN 1744 Part 1 | Active
|
- Tests for chemical properties of aggregates Part 5: Determination of acid soluble chloride salts
| BS EN 1744-5 | Active
|
- Standard Test Method for Organic Impurities in Fine Aggregates for Concrete
| ASTM C40/C40M | Active
|
- Tests for geometrical properties of aggregates. Assessment of fines. Methylene blue test
| BS EN 933 Part 9 | Active
|
| | EMT-M-OP-CH-DXB-MD417 | Active
|
Air Quality Monitoring |
| | - Total Suspended Particulate (TSP) , LOQ: 0.0 mg/m³
| US EPA Method 5 | Active
|
- Determination of Sulphur Dioxide (SO2) LOQ: 1 mg/m³
| US EPA 6C | Active
|
- Determination of Nitrogen Dioxide (NO2) LOQ: 1 mg/m³
| US EPA Method 7E | Active
|
- Carbon Monoxide LOQ: 1 mg/m³
| US EPA Method 10 | Active
|
- Carbon Dioxide LOQ: 1 mg/m³
| US EPA Method 3A | Active
|
| US EPA Method 3A | Active
|
- Volatile Organic Compounds (VOC’s) LOQ: 1 mg/m³
| US EPA Method 25A | Active
|
| ISO 11338 part 1 | Active
|
- Dioxins, Furans and PCB's LOQ: 1 ng/m³
| USEPA Method 23 EN 1948 part 1 | Active
|
- Heavy Metals As, Bo, Cd, Co, Cr, Cr(VI), Cu, Fe, Hg, K, Mg, Mn, Na, Ni, Pb, Mo, Se, V, Zn LOQ: 0.001 mg/m³
| USEPA Method M29 EN 14385 | Active
|
- Hydrogen Chloride LOQ: 0.01 mg/m³
| USEPA Method 26 EN 1191 | Active
|
- Hydrogen Flouride LOQ: 0.01 mg/m³
| USEPA Method 13B & 26 | Active
|
- Hydrogen Sulphide LOQ: 0.01 mg/m³
| USEPA Method 11 | Active
|
- Hydrogen Cyanide LOQ: 0.1 mg/m³
| USEPA OTM 29 | Active
|
| EN 14791 | Active
|
- Sulphur Dioxide (Wet Chemical) LOQ: 0.01 mg/m³
| USEPA Method 6 EN 14791 | Active
|
- Sulphur Dioxide LOQ: 1 ppm
| USEPA CTM 30 | Active
|
- Carbon Monoxide LOQ: 1 ppm
| USEPA CTM 30 | Active
|
- Oxide of Nitrogen (as NO2) LOQ: 1 ppm
| USEPA CTM 30 | Active
|
| USEPA CTM 30 | Active
|
- Indoor Air Quality / Ambient Atmosphere
| - Carbon Monoxide LOD 0.02 ppm
| In-house method EL-M-OP-AA-MD002 | Active
|
| In-house method EL-M-OP-AA-MD002 | Active
|
- Sulphur Dioxide LOD : 0.01 ppm
| In-house method EL-M-OP-AA-MD002 | Active
|
| In-house method EL-M-OP-AA-MD002 | Active
|
- Oxides of Nitrogen (as NO2) LOD: 0.01 ppm
| In-house method EL-M-OP-NO-MD001 | Active
|
- TSP, PM1, PM2.5 & PM10 LOD: 1 ug/m³
| In-house method EL-M-OP-AQ-MD003 | Active
|
- TSP, 0.3, 0.5, 1.0, 2.5, 5.0 and 10.0 micron LOD: 1 ug/m³
| In-house method EL-M-OP-AQ-MD004 | Active
|
- Carbon Dioxide (CO₂) LOD: 50ppm Range 0-10,000 ppm
| In-house method EL-M-OP-AQ-MD004 | Active
|
- Carbon monoxide (CO) LOD 0.5 ppm Range 0-750 ppm
| In-house method EL-M-OP-AQ-MD004 | Active
|
- Volatile organic compound (VOC) LOD 0.02ppm Range 0-20ppm
| In-house method EL-M-OP-AQ-MD004 | Active
|
- Hydrogen Sulphide (H₂S) LOD 0.03ppm Range 0-50ppm
| In-house method EL-M-OP-AQ-MD004 | Active
|
- Ozone (O₃) LOD 0.02 ppm Range 0-1 ppm
| In-house method EL-M-OP-AQ-MD004 | Active
|
- Sulphur Dioxide (SO₂) LOD 0.1ppm Range 0-30 ppm
| In-house method EL-M-OP-AQ-MD004 | Active
|
- Nitrogen Dioxide (NO₂) LOD 0.02ppm Range 0-20 ppm
| In-house method EL-M-OP-AQ-MD004 | Active
|
- Ammonia (NH₃) LOD 1ppm Range 0-100ppm
| In-house method EL-M-OP-AQ-MD004 | Active
|
- Particulate LOD 0.3um Range 0.3-145um
| In-house method EL-M-OP-AQ-MD004 | Active
|
- Formaldehyde (CH₂O) LOD 20ppb Range 0-1000ppb
| In-house method EL-M-OP-AQ-MD004 | Active
|
- Indoor Air Quality/ Personal Exposure
| - Sampling of LEED IAQ VOC Suite with subsequent analysis by an ISO/IEC 17025 accredited laboratory
| In-house method EL-M-OP-OH-MD001 | Active
|
- Sampling of VOCs with subsequent analysis by an ISO/IEC 17025 accredited laboratory
| In-house method EL-M-OP-OH-MD001 | Active
|
- Sampling of BTEX (Benzene, Toluene, Ethyl Benzene, Xylene) with subsequent analysis by an ISO/IEC 17025accredited laboratory
| In-house method EL-M-OP-OH-MD001 | Active
|
- Sampling of n-hexane, Cyclohexane, n-pentane, n-octane with subsequent analysis by an ISO/IEC 17025 accredited laboratory
| In-house method EL-M-OP-OH-MD001 | Active
|
- Sampling of Ammonia with subsequent analysis by an ISO/IEC 17025 accredited laboratory
| In-house method EL-M-OP-OH-MD001 | Active
|
- Sampling of Formaldehyde, Acetaldehyde with subsequent analysis by an ISO/IEC 17025 accredited laboratory
| In-house method EL-M-OP-OH-MD001 | Active
|
- Sampling of Amines with subsequent analysis by an ISO/IEC 17025 accredited laboratory
| In-house method EL-M-OP-OH-MD001 | Active
|
- Sampling of Hydrogen Sulphide with subsequent analysis by an ISO/IEC 17025 accredited laboratory
| In-house method EL-M-OP-OH-MD001 | Active
|
- Sampling of phenol with subsequent analysis by an ISO/IEC 17025 accredited laboratory
| In-house method EL-M-OP-OH-MD001 | Active
|
- Personal Exposure & Indoor Air Quality/ Ambient Monitoring
| - Personal Noise Exposure Monitoring LOD 5dB Range 0-140 dB
| In-house method EL-M-OP-OH-MD002 | Active
|
- Inhalable Dust and Respirable Dust Exposure Monitoring LOD 0.1 mg/m³ Range 0-30 mg/m³
| In-house method EL-M-OP-OH-MD005 | Active
|
| - Indoor Air Quality / Ambient Atmosphere
| - Noise LOD: 0.1 dB Range: 20-140 dB
| ISO 1996 Part 2 | Active
|
| | | In-house method EL-M-OP-MIC-SOP028 | Active
|
| In-house method EL-M-OP-MIC-SOP028 | Active
|
| In-house method EL-M-OP-MIC-SOP028 | Active
|
| | NIOSH Method 800:1998 | Active
|
| IESO 1220 | Active
|
| IESO 1220 | Active
|
| In-house method EL-M-OP-MIC-SOP028 | Active
|
| In-house method EL-M-OP-MIC-SOP028 | Active
|
| In-house method EL-M-OP-MIC-SOP028 | Active
|
Environmental |
| | | APHA 4500 H+ B | Active
|
| APHA 2540 D | Active
|
| APHA 2540 C BS 1377 Part 3 | Active
|
| EL-M-OP-CH-DXB-MD414 APHA 5520 B | Active
|
- Biological Oxygen Demand-5 days
| EL-M-OP-CH-DXB-MD304 APHA 5210B | Active
|
| APHA 5220 B | Active
|
- Metals-Cu, Cd, Pb, Zn, Ni, Cr, Fe, Mn ,Ag, Co
| APHA 3030 APHA 3120 | Active
|
| - Determination of Extractable Petroleum Hydrocarbons (EPH)
| EMT-M-OP-CH-DXB-MD401 EPA 8015M | Active
|
- Determination of Poly Aromatic Hydrocarbons (PAH) in Soils and Waters by GCMS
| EMT-M-OP-CH-DXB-MD403 EPA 625 & EPA 8270D | Active
|
- Determination of Volatile Petroleum Hydrocarbons (VPH) by GCFID & BTEX
| EMT-M-OP-CH-DXB-MD405 EPA 8015M | Active
|
EMT-M-OP-CH-DXB-MD408 EPA 8260B | Active
|
- Determination of Trace Level Mercury by PSA Cold Vapour Atomic Fluorescence Spectrometry
| EMT-M-OP-CH-DXB-MD114 | Active
|
| - Determination of Volatile Organic Compounds (VOC) in Waters by GCMS with Head Space
| EL-M-OP-CH-DXB- MD404A EPA 5021A EPA 8260B | Active
|
- Determination of Organo-Chlorine Pesticide (OCP) in waters by GC-ECD to EX-M-OP-CH-DXB-MD402 & EPA 8081A.
| EL-M-OP-CH-DXB-MD402 EPA 8081A | Active
|
- Determination of Metals and other Elements in Potable/Drinking, Effluent & saline Waters by ICP-OES.
| EMT -M-OP-CH-DXB-MD106B | Active
|
EMT -M-OP-CH-DXB-MD106A | Active
|
EMT -M-OP-CH-DXB-MD106C | Active
|
- Determination of Nitrate/Nitrite, Ammoniacal Nitrogen in Waters by Segmented Flow / Colorimetry
| EMT -M-OP-CH-DXB-MD323A | Active
|
- Determination of Inorganics Anions in Water by Ion Chromatography
| EMT -M-OP-CH-DXB-MD322 | Active
|
- Determination of Bromate by Ion Chromatography
| EL -M-OP-CH-DXB- MD322 APHA 4110 D | Active
|
- Determination of Metals and Other Elements in Waters by ICP-MS
| EMT -M-OP-CH-DXB-MD106D | Active
|
- Organophosphorous Pesticides (OPP`s)
| EL-M-OP-CH-MD430 EPA 8270D EPA 3550C EPA 8141B | Active
|
| EMT-M-OP-CH-DXB-MD415 EPA 528 | Active
|
- Polychlorinated Biphenyls (PCBs)
| EMT-M-OP-CH-DXB-MD416 EPA 8270D EPA 3550C | Active
|
- Alkalinity (inc Total ,p, m, Carbonate, Bicarbonate, Hydroxide)
| EL-M-OP-CH-DXB-MD210 APHA 2320 B | Active
|
- Ammoniacal Nitrogen [NH4-N]
| EL-M-OP-CH-DXB-MD302 HACH 8155 | Active
|
- Chlorine Residual (Free & Total)
| EL-M-OP-CH-DXB-MD206 APHA 4500-Cl- G HACH 8167 HACH 8021 | Active
|
| EMT-M-OP-CH-DXB-MD204 | Active
|
| EL-M-OP-CH-DXB-MD201 APHA 2510 | Active
|
| EMT-M-OP-CH-MD304 APHA 4500-O C | Active
|
- Easy Liberated Cyanide (Free)
| EMT-M-OP-CH-DXB-MD310 EPA 365.2 | Active
|
| EL-M-OP-CH-DXB-MD328 EPA 340.1 HACH 8029 | Active
|
| EMT-M-OP-CH-DXB-MD328A | Active
|
| EMT-M-OP-CH-DXB-MD325 APHA 4500 Cl | Active
|
| EMT-M-OP-CH-DXB-MD324 BS EN 196-2 | Active
|
- Hardness (Total and calcium)
| EL-M-OP-CH-DXB-MD211 EL-M-OP-CH-DXB-MD211A APHA 2340 B APHA 2340 C APHA 3500-Ca - B | Active
|
| EMT-M-OP-CH-DXB-MD330 APHA 3500-Cr B | Active
|
- Nitrite [Nitrite-Nitrogen]
| EMT-M-OP-CH-DXB-MD317 | Active
|
- Nitrate [Nitrate-Nitrogen]
| EMT-M-OP-CH-DXB-MD315 | Active
|
| EMT-M-OP-CH-DXB-MD337 APHA 4500-Norg B | Active
|
| EMT-M-OP-CH-DXB-MD318 ASTM D5176 | Active
|
| EMT-M-OP-CH-DXB-MD326 EPA 365.2 | Active
|
| EMT-M-OP-CH-DXB-MD333 EPA 420.1 | Active
|
| EMT-M-OP-CH-DXB-MD201 APHA 2510 APHA 2520 | Active
|
| EMT-M-OP-CH-DXB-MD332A | Active
|
| EMT-M-OP-CH-DXB-MD332B | Active
|
- Total Organic Carbon (TOC)
| EL-M-OP-CH-DXB-MD319 APHA 5310 B | Active
|
| EMT-M-OP-CH-DXB-MD203 APHA 2130A | Active
|
| EMT-M-OP-CH-DXB-MD309 APHA 4110 D | Active
|
| EL-M-OP-CH-DXB-MD327 HACH 8185/8186 | Active
|
- Fixed and volatile solids
| APHA 2540 G | Active
|
- Oxidation/reduction Potential
| APHA 2580 B | Active
|
| - Determination of metals by ICP OES
| EL-M-OP-CH-DXB-MD112 EPA 3050 B APHA 3120 B | Active
|
- Determination of Volatile Organic Compounds (VOC) in Soils by GCMS with Head Space
| EMT -M-OP-CH-DXB-MD404B EPA 5021A EPA 8260B | Active
|
| - Boron (Hot Water Extraction)
| EL-M-OP-CH-DXB-MD140 APHA 3120 B | Active
|
| EL-M-OP-CH-DXB-MD330 APHA 3500-Cr B | Active
|
- Easy Liberated Cyanide (Free)
| EMT-M-OP-CH-DXB-MD310 EPA 365.2 | Active
|
| EL-M-OP-CH-DXB-MD415B EPA 8270D | Active
|
- Polychlorinated Biphenyls (PCB's)
| EMT-M-OP-CH-DXB-MD416 EPA 3350C EPA 8270D | Active
|
| EMT-M-OP-CH-DXB-MD328 EPA 340.1 | Active
|
| EMT-M-OP-CH-DXB-MD332 APHA 4500 S | Active
|
| EMT-M-OP-CH-DXB-MD315A EMT-M-OP-CH-DXB-MD315 | Active
|
| EMT-M-OP-CH-DXB-MD317 | Active
|
| EMT-M-OP-CH-DXB-MD302 | Active
|
| EMT-M-OP-CH-DXB-MD326 EPA 365.2 | Active
|
- Total, organic and TKN nitrogen
| EMT-M-OP-CH-DXB-MD337 | Active
|
- Organochlorine Pesticide (OCP)
| EMT-M-OP-CH-MD402 | Active
|
| - Nitrate, Nitrite, Ammonia, Cyanide, Orthophosphate, Hexavalent chromium, Sulfate, Chloride, Phenols, Silica, Fluoride
| Skalar/EMT-M-OP-CH-DXB-MD323C | Active
|
| | - Total Petroleum Hydrocarbons -Criteria Working Group (TPH CWG) – EPH fraction
| EL-M-OP-CH-DXB-MD432 NJDEP EPA 8015D | Active
|
| - Total Petroleum Hydrocarbons -Criteria Working Group (TPH CWG) – VPH fraction
| EL-M-OP-CH-DXB-MD433 EPA 5021A EPA 8260D | Active
|
| EL-M-OP-CH-DXB-MD323D MicroDist HACH | Active
|
| | | EL-M-OP-MIC-MD001 APHA 9215B/ colony count technique | Active
|
- Enumeration of Total Coliforms
| EL-M-OP-MIC-MD002 APHA 9223 B/ MPN | Active
|
EL-M-OP-MIC-MD003 APHA 9222 B/ MF colony count technique | Active
|
| EL-M-OP-MIC-MD002 APHA 9223 B/ MPN | Active
|
- Enumeration of Faecal Coliforms
| EL-M-OP-MIC-MD004 APHA 9222 D/ MF colony count technique | Active
|
- Enumeration of Enterococci (Faecal streptococci)
| EL-M-OP-MIC-MD005 BS EN ISO 7899-2 | Active
|
- Water: Drinking water Bottled water Potable water Pool and spa water Irrigation water Cooling tower Dental clinic water Fountain water
| - Enumerati on of Legionella Matrix A: Water with low background Matrix B: Water with high background
| EL-M-OP-MIC-MD023 ISO 11731 Matrix A: Procedures 5,7 Matrix B: Procedures 8,9,10 | Active
|
- Enumeration of Clostridium perfringens
| Standing Committee of Analysts - The Microbiological of Drinking Water Part 6 Method C | Active
|
| EL-M-OP-MIC-MD052 APHA 9222 I | Active
|
EL-M-OP-MIC-MD050 APHA 9221 F | Active
|
- Enumeration of Enterococci (Faecal streptococci)
| EL-M-OP-MIC-MD005 BS EN ISO 7899-2 | Active
|
- Enumeration of Faecal Coliforms
| EL-M-OP-MIC-MD051 APHA 9221 E | Active
|
- Enumeration of Enterococci (Faecal Streptococci) (Enterococci)
| APHA 9230 C | Active
|
- Enumeration of Pseudomonas aeruginosa
| EL-M-OP-MIC-MD006 BS EN ISO 16266 | Active
|
- Detection of Salmonella species (Presence / Absence)
| APHA 9260 B | Active
|
- Enumeration of Sulphite Reducing Clostridia
| Standing Committee of Analysts - The Microbiological of Drinking Water Part 6 Method A | Active
|
- Enumeration of Total Coliforms
| EL-M-OP-MIC-MD003A APHA 9221 B | Active
|
- Detection of Vibrio parahaemolyticus (Presence/Absence)
| Standing Committee of Analysts - The Microbiological of Drinking Water Part 10 Method B | Active
|
| EL-M-OP-MIC-MD011 MFHPB-22 Colony count technique | Active
|
| EL-M-OP-MIC-MD011 MFHPB-22 Colony count technique | Active
|
| | EL-M-OP-MIC-MD050 APHA 9221 F | Active
|
- Enumeration of Faecal Coliforms
| EL-M-OP-MIC-MD051 APHA 9221 E | Active
|
- Detection of Salmonella species (Presence / Absence)
| UK Standing Committee of Analysts - The Microbiological of Sludge Part 4 | Active
|
- Enumeration of Total Coliforms
| EL-M-OP-MIC-MD003A APHA 9221 B | Active
|
- Water Sea water Fresh water Ballast water
| - Detection of Vibrio cholerae (Presence/Absence)
| Standing Committee of Analysts - The Microbiological of Drinking Water Part 10 Method B | Active
|
- Detection of Vibrio parahaemolyticus (Presence/Absence)
| Standing Committee of Analysts - The Microbiological of Drinking Water Part 10 Method B | Active
|
| | - Water Sample Collection for Legionella Testing
| EL-M-OP-MIC-SOP012 BS 7592 Section 2: Routine sSampling | Active
|
| | EMT-M-OP-EN-SOP026 ISO 18593 | Active
|
Metallurgy |
- Mechanical & Metallurgical
| - Iron, steel and other ferrous/non ferrous metals
| - Standard Test Methods and Definitions for Mechanical Testing of Steel Products Standard Test Methods for Notched Bar Impact Testing of Metallic Materials Metallic materials. Charpy pendulum impact test. Test method Charpy impact test (temperature range -196°C to ambient temperature)
| ASTM A370 ASTM E23 A BS EN ISO 148-1 | Active
|
- Standard Test Methods for Tension Testing of Metallic Materials Metallic materials. Tensile testing. Method of test at room temperature Tensile test (forces up to 2000 kN)
| ASTM E8/E8M BS EN ISO 6892-1 API 5L 46th Edition ASTM A370 | Active
|
- Standard Test Methods for Vickers Hardness and Knoop Hardness of Metallic Materials Metallic materials. Vickers hardness test. Calibration of referENce blocks Vickers hardness test (HV5 & HV10)
| ASTM E92 BS EN ISO 6507-1 | Active
|
- Reinforcing bars, wire rod and wire for reinforcement of concrete
| - Steel for the reinforcement of concrete. Weldable reinforcing steel. Bar, coil and decoiled product. Specification Mass per unit length
| BS 4449 +A3 | Active
|
| - Qualification standard for welding and brazing procedures, welders, brazers, and welding and brazing operators Structural Welding Code –SteeL Welding of Pipelines and Related Facilities Destructive tests on welds in metallic material Bend test
| ASME IX AWS D1.1/D1.1M API 1104 22nd Edition BS EN ISO 5173 | Active
|
- Destructive tests on welds in metallic materials. Fracture test Fracture & nick break test
| BS EN ISO 9017 API 1104 22nd Edition ASME IX AWS D1.1/D1.1M | Active
|
- Destructive tests on welds in metallic materials. Hardness testing. Hardness test on arc welded joints Hardness
| BS EN ISO 9015-1 API 1104 22nd Edition ASME IX AWS D1.1/D1.1M | Active
|
- Destructive tests on welds in metallic materials. Macroscopic and microscopic examination of welds Macro examination
| BS EN ISO 17639 API 1104 22nd Edition ASME IX AWS D1.1/D1.1M | Active
|
- Destructive tests on welds in metallic materials. Transverse tensile test Destructive tests on welds in metallic materials. Longitudinal tensile test on weld metal in fusion welded joints Tensile
| BS EN ISO 4136 BS EN ISO 5178 API 1104 22nd Edition ASME IX AWS D1.1/D1.1M | Active
|
| | - Carbon Steel Bar for the reinforcement of concrete (Steel Bend test)
| BS 4449 Appendix C Clause C.1.6.1 ASTM A615/A615M | Active
|
- Carbon Steel Bars for the reinforcement of Concrete (Steel tensile strength test)
| BS 4449 BS EN 10002-1 | Active
|
- Carbon Steel Bars for the reinforcement of Concrete (Steel rebend tests)
| BS 4449 Annex E Clause E.1.6 | Active
|
| - Carbon Steel, Low Alloy Steel, and Stainless Steel
| - Chemical analysis of metals by Optical Emission Spectrometer
| EMT-M-OP-CH-MD101, ASTM E415 ASTM A751 ASTM E1086 | Active
|
Food |
| - Swabs: Swabs from food chain environments and personnel
| | EL-M-OP-MIC-MD011 MFHPB-22 | Active
|
| EL-M-OP-MIC-MD011 MFHPB-22 | Active
|
| | EL-M-OP-MIC-MD026 ISO 4833-1 Amd 1 | Active
|
- Enumeration of Enterobacteriaceae
| EL-M-OP-MIC-MD033 ISO 21528-2 | Active
|
- Enumeration of Total Coliforms
| EMT-M-OP-EN-MD025 ISO 4832 | Active
|
- Detection of Salmonella species
| EL-M-OP-MIC-MD027 ISO 6579-1 AMD 1 | Active
|
- Enumeration of Coagulase positive staphylococci including Staphylococcus aureus
| EL-M-OP-MIC-MD028 ISO 6888-1 AMD 1 | Active
|
| EL-M-OP-MIC-MD062 AOAC OMA 990.12 3M Petrifilm method | Active
|
| EL-M-OP-MIC-MD063 AOAC OMA 991.14 3M Petrifilm method | Active
|
| EL-M-OP-MIC-MD065 Selective E.coli, 3M Petrifilm method, version 2 | Active
|
- Enumeration of Staphylococcus aureus
| EL-M-OP-MIC-MD067 AOAC OMA 2003.7, 2003.8 & 2003.11 3M Petrifilm method | Active
|
- Enumeration of Enterobacteriaceae
| EL-M-OP-MIC-MD064 AOAC OMA 2003.01 3M Petrifilm method | Active
|
| EL-M-OP-MIC-MD066 AOAC OMA 997.02 3M Petrifilm method | Active
|
| EL-M-OP-MIC-MD066 AOAC OMA 997.02 3M Petrifilm method | Active
|
| EL-M-OP-MIC-MD029 ISO 7251 AMD 1 | Active
|
- Enumeration of Bacillus cereus
| EL-M-OP-MIC-MD030 ISO 7932 AMD 1 | Active
|
- Enumeration of Clostridium perfringens
| EL-M-OP-MIC-MD031 ISO 7937 | Active
|
| EL-M-OP-EN-MD011 MFHPB-22 Colony count technique | Active
|
| EL-M-OP-MIC-MD011 MFHPB-22 Colony count technique | Active
|
- Sea food and sea food products
| - Detection of Vibrio cholerae
| EL-M-OP-MIC-MD034 ISO 21872-1 | Active
|
- Detection of Vibrio parahaemolyticus
| EL-M-OP-MIC-MD034 ISO 21872-1 | Active
|
- Swabs: Swabs from food chain environments and personnel
| | EL-M-OP-MIC-MD026 ISO 4833-1 Amd 1 | Active
|
- Enumeration of Enterobacteriaceae
| EL-M-OP-MIC-MD033 ISO 21528-2 | Active
|
- Enumeration of Total Coliforms
| EL-M-OP-MIC-MD025 ISO 4832 | Active
|
| - Detection of Listeria species including Listeria monocytogenes
| EL-M-OP-EN-MD032 ISO 11290-1 | Active
|
- Swabs: Swabs from food chain environments and personnel
| - Enumeration of Coagulase positive staphylococci including Staphylococcus aureus
| EL-M-OP-MIC-MD028 ISO 6888-1 AMD 1 | Active
|
| EL-M-OP-MIC-MD062 AOAC OMA 990.12 3M Petrifilm method | Active
|
| EL-M-OP-MIC-MD063 AOAC OMA 991.14 3M Petrifilm method | Active
|
| EL-M-OP-MIC-MD065 Selective E.coli, 3M Petrifilm method, version 2 | Active
|
- Enumeration of Staphylococcus aureus
| EL-M-OP-MIC-MD067 AOAC OMA 2003.7, 2003.8 & 2003.11, 3M Petrifilm method | Active
|
- Enumeration of Enterobacteriaceae
| EL-M-OP-MIC-MD064 AOAC OMA 2003.01 3M Petrifilm method | Active
|
| EL-M-OP-MIC-MD066 AOAC OMA 997.02 3M Petrifilm method | Active
|
| EL-M-OP-MIC-MD066 AOAC OMA 997.02 3M Petrifilm method | Active
|
CM Green Building |
| | - Determination of VOCs in paint by gas chromatography
| EL-M-OP-CH-DXB-MD404C ISO 11890 Part 2 | Active
|
- Determination of VOCs in paint by difference
| EL-M-OP-CH-DXB-MD404D EPA 24 ISO 11890 Part 1 ASTM D3960 ASTM D2369 | Active
|
- Determination of trace metals in Paint
| EL-M-OP-CH-DXB-APHA 3120 B | Active
|