Al Mahasin Calibration Devices LLC

Initial Accreditation Date:Jun 14 , 2020

Contacts Info

Address

Sharjah, United Arab Emirates

PO box / Zip Code

40280

Email

info@amcalme.com; aamil@amecuae.com

Website

www.amcalme.com

Main Field

Calibration Laboratories

Valid Since:Jan 25 , 2024

Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Balance & Scale
  • Top loading weighing scale
Active
Electrical
  • DC Voltage Calibration of Measuring Instruments
  • Direct comparison of generated DC voltage from calibrator Equipment Used: Multi-product Calibrator FLUKE 5522A Calibration Procedure: AMCAL/SOP-03 EURAMET Cg-15 ver.3.0
  • 0 mV to 330 mV
14 µvLaboratoryActive
  • >0.33 V to 3.3 V
0.11 mVLaboratoryActive
  • >3.3 V to 33 V
1.0 mVLaboratoryActive
  • >33 V to 330 V
2.7 mVLaboratoryActive
  • >330 V to 1000 V
32 mVLaboratoryActive
  • AC Voltage Calibration of Measuring Instruments
  • Direct comparison of generated AC voltage from calibrator Equipment Used: Multi-product Calibrator FLUKE 5522A Calibration Procedure: AMCAL/SOP-03 EURAMET Cg-15 ver.3.0
  • (10 Hz to 1 kHz ) 1 mV to 33 mV
0.17 mVLaboratoryActive
  • (10 Hz to 1 kHz ) >33 mV to 330 mV
0.18 mVLaboratoryActive
  • (10 Hz to 1 kHz ) >0.33 V to 3.3 V
1.8 mVLaboratoryActive
  • (10 Hz to 1 kHz ) > 3.3 V to 33 V
15 mVLaboratoryActive
  • (10 Hz to 1 kHz ) >33 V to 330 V
0.17 VLaboratoryActive
  • (10 Hz to 1 kHz ) >330 V to 1020 V
0.49 VLaboratoryActive
  • DC Current Calibration of Measuring Instruments
  • Direct comparison of generated DC current from calibrator Equipment Used: Multi-product Calibrator FLUKE 5522A Calibration Procedure: AMCAL/CPET-03 EURAMET Cg-15 ver.3.0
  • 0 A to 0.33 mA
78 nALaboratoryActive
  • >0.33 mA to 3.3 mA
0.59 μALaboratoryActive
  • >3.3 mA to 33 mA
5.5 μALaboratoryActive
  • >33 mA to 330 mA
60 μALaboratoryActive
  • >0.33 A to 3.3 A
2.0 mALaboratoryActive
  • >3.3 A to 20 A
17 mALaboratoryActive
  • DC Current Clamp Calibration of Measuring Instruments
  • Comparison to calibrator 5522A passing current through 50 turn current coil Calibration Procedure: AMCAL/SOP-05 EURAMET Cg-15 ver.3.0 I=Measured Current Value
  • 20 A to 1000 A
6.0 ALaboratoryActive
  • Resistance Calibration of Measuring Instruments
  • Direct comparison of resistance from calibrator Equipment used: Multi-product Calibrator FLUKE 5522A Calibration Procedure: AMCAL/SOP-03 EURAMET Cg-15 ver.3.0
  • 0 Ω to 10 Ω
2.2 mΩLaboratoryActive
  • > 10 Ω to 100 Ω
6.7 mΩLaboratoryActive
  • > 100 Ω to 1 kΩ
50 mΩLaboratoryActive
  • Direct comparison of resistance from calibrator Equipment used: Multi-product Calibrator FLUKE 5522A Calibration Procedure: AMCAL/SOP-03 EURAMET Cg-15 ver.3.0
  • > 1 kΩ to 10 kΩ
0.5 ΩLaboratoryActive
  • > 10 kΩ to 100 kΩ
4.9 ΩLaboratoryActive
  • Direct comparison of resistance from calibrator Equipment used: Multi-product Calibrator FLUKE 5522A Calibration Procedure: AMCAL/SOP-03 EURAMET Cg-15 ver.3.0
  • > 100 kΩ to 1 MΩ
0.08 kΩLaboratoryActive
  • Direct comparison of resistance from calibrator Equipment used: Multi-product Calibrator FLUKE 5522A Calibration Procedure: AMCAL/SOP-03 EURAMET Cg-15 ver.3.0
  • > 1 MΩ to 10 MΩ
3.1 kΩLaboratoryActive
  • Direct comparison of resistance from calibrator Equipment used: Multi-product Calibrator FLUKE 5522A Calibration Procedure: AMCAL/SOP-03 EURAMET Cg-15 ver.3.0
  • > 10 MΩ to 100 MΩ
0.13 MΩLaboratoryActive
  • > 100 MΩ to 1 GΩ
35 MΩLaboratoryActive
  • AC Current Calibration of measuring Instruments
  • Direct comparison of generated AC current from calibrator Equipment Used: Multi-Product Calibrator FLUKE 5522A Calibration Procedure: AMCAL/SOP-03 EURAMET Cg-15 ver.3.0
  • (10 Hz to 1 kHz ) 30 µA to 330 µA
0.96 μALaboratoryActive
  • (10 Hz to 1 kHz ) >0.33 mA to 3.3 mA
8.0 μALaboratoryActive
  • (10 Hz to 1 kHz ) >3.3 mA to 33 mA
49 μALaboratoryActive
  • (10 Hz to 1 kHz ) >0.33 A to 3.3 A
5.5 mALaboratoryActive
  • (10 Hz to 1 kHz ) > 3.3 A to 20 A
32 mALaboratoryActive
  • AC Current Clamp Calibration of Measuring Instruments
  • Comparison to Calibrator 5522A passing current through 50 turn current coil Calibration Procedure: AMCAL/SOP-05 EURAMET Cg-15 ver.3.0
  • 20 A to 1000 A (45 Hz to 65 Hz)
6.8 ALaboratoryActive
  • CAPACITANCE Calibration of Measuring Instruments
  • Direct comparison of generated Capacitance from calibrator Equipment Used: Multi-Product Calibrator FLUKE 5522A Calibration Procedure: AMCAL/SOP-03 EURAMET Cg-15 ver.3.0
  • 1 nF
24 pFLaboratoryActive
  • Direct comparison of generated Capacitance from calibrator Equipment Used: Multi-Product Calibrator FLUKE 5522A Calibration Procedure: AMCAL/SOP-03 EURAMET Cg-15 ver.3.0
  • >1 nF to 10 nF
55 pFLaboratoryActive
  • >10 nF to 100 nF
0.55 nFLaboratoryActive
  • >100 nF to 1 µF
5.5 nFLaboratoryActive
  • >1 µF to 10 µF
56 nFLaboratoryActive
  • >10 µF to 100 µF
0.87 μFLaboratoryActive
  • Frequency Calibration of Measuring Instruments
  • Direct comparison of generated Frequency from calibrator Equipment Used: Multi-Product Calibrator FLUKE 5522A Calibration Procedure: AMCAL/SOP-03 AMCAL/SOP-03 EURAMET Cg-15 ver.3.0
  • 1 Hz to 100 Hz
0.40 mHzLaboratoryActive
  • Direct comparison of generated Frequency from calibrator Equipment Used: Multi-Product Calibrator FLUKE 5522A Calibration Procedure: AMCAL/SOP-03 AMCAL/SOP-03 EURAMET Cg-15 ver.3.0
  • >100 Hz to 100 kHz
0.70 HzLaboratoryActive
  • Temperature Calibration of Resistive Temperature Device indicators
  • Direct comparison of generated temperature from calibrator Equipment Used: Multi-Product Calibrator FLUKE 5522A Calibration Procedure: AMCAL/SOP-09 EURAMET Cg-11 ver.2.0
  • ~100 °C to 800 °C
0.40°CLaboratoryActive
  • Temperature Calibration of Thermocouple indicators
  • Direct comparison of generated temperature from calibrator Equipment Used: Multi-Product Calibrator FLUKE 5522A Calibration Procedure: AMCAL/SOP-08 EURAMET Cg-11 ver.2.0
  • (Type K) -200 °C to 1372 °C
0.65 °CLaboratoryActive
  • (Type J) -210 °C to 1200 °C
0.46 °CLaboratoryActive
  • (Type N) -200 °C to 1300 °C
0.52 °CLaboratoryActive
  • (Type R) 0 °C to 1767 °C
0.91 °CLaboratoryActive
  • (Type S) 0 °C to 1767 °C
0.76 °CLaboratoryActive
  • (Type T) -250 °C to 400 °C
0.54 °CLaboratoryActive