Emirates Engineering Calibration Laboratory

Initial Accreditation Date:Oct 03 , 2017

Contacts Info

Address

Dubai, United Arab Emirates

PO box / Zip Code

686

Email

ComplianceMonitoringRegulatoryAffairs@emirates.com

Website

www.emirates.com

Main Field

Calibration Laboratories

Valid Since:Feb 15 , 2024

Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Balance & Scale
  • Top loading weighing scale
Active
Electrical-Measuring
  • DC Voltage
  • Comparison Method using work instruction CM2-0 based on EURAMET CG-15
  • Up to 330 mV
6.9 µVEmirates Engineering Calibration LaboratoryActive
  • >330 mV to 3.3 V
0.60 mVEmirates Engineering Calibration LaboratoryActive
  • >3.3 V to 33 V
0.86 mVEmirates Engineering Calibration LaboratoryActive
  • >33 V to 330 V
6.2 mVEmirates Engineering Calibration LaboratoryActive
  • >330 V to 1000 V
17 mVEmirates Engineering Calibration LaboratoryActive
  • AC Voltage @ 45 Hz and 1 kHz
  • 1 mV to 330 mV
60 µVEmirates Engineering Calibration LaboratoryActive
  • >0.3 V to 3 V
41 mVEmirates Engineering Calibration LaboratoryActive
  • >3 V to 30 V
41 mVEmirates Engineering Calibration LaboratoryActive
  • >30 V to 100 V
44 mVEmirates Engineering Calibration LaboratoryActive
  • >100 V to 300 V
62 mVEmirates Engineering Calibration LaboratoryActive
  • >300 V to 1000 V
0.13 VEmirates Engineering Calibration LaboratoryActive
  • DC Current
  • 1 µA to 300 µA
52 nAEmirates Engineering Calibration LaboratoryActive
  • >0.3 mA to 3 mA
0.34 µAEmirates Engineering Calibration LaboratoryActive
  • >3 mA to 30 mA
2.6 µAEmirates Engineering Calibration LaboratoryActive
  • >30 mA to 100 mA
10 µAEmirates Engineering Calibration LaboratoryActive
  • >0.1 A to 1 A
0.32 mAEmirates Engineering Calibration LaboratoryActive
  • >1 A to 3 A
0.90 mAEmirates Engineering Calibration LaboratoryActive
  • >3A to 11 A
4.4 mAEmirates Engineering Calibration LaboratoryActive
  • AC Current @ 50 Hz
  • 1 µA to 300 µA
0.37 µAEmirates Engineering Calibration LaboratoryActive
  • >0.3 mA to 3 mA
2.5 µAEmirates Engineering Calibration LaboratoryActive
  • >3 mA to 30 mA
11 µAEmirates Engineering Calibration LaboratoryActive
  • >30 mA to 100 mA
47 µAEmirates Engineering Calibration LaboratoryActive
  • >0.1 A to 1 A
0.48 mAEmirates Engineering Calibration LaboratoryActive
  • >1 A to 3 A
1.5 mAEmirates Engineering Calibration LaboratoryActive
  • >3A to 11 A
6.2 mAEmirates Engineering Calibration LaboratoryActive
  • DC Resistance
  • 1 Ω to 10 Ω
9.3 mΩEmirates Engineering Calibration LaboratoryActive
  • >10 Ω to 30 Ω
4.5 mΩEmirates Engineering Calibration LaboratoryActive
  • >30 Ω to 100 Ω
6.3 mΩEmirates Engineering Calibration LaboratoryActive
  • >100 Ω to 300 Ω
11 mΩEmirates Engineering Calibration LaboratoryActive
  • >0.3 kΩ to 1 kΩ
0.20 ΩEmirates Engineering Calibration LaboratoryActive
  • >1 kΩ to 3 kΩ
0.28 ΩEmirates Engineering Calibration LaboratoryActive
  • >3 kΩ to 10 kΩ
0.44 ΩEmirates Engineering Calibration LaboratoryActive
  • >10 kΩ to 30 kΩ
0.90 ΩEmirates Engineering Calibration LaboratoryActive
  • >30 kΩ to 100 kΩ
2.5 ΩEmirates Engineering Calibration LaboratoryActive
  • >100 kΩ to 300 kΩ
10 ΩEmirates Engineering Calibration LaboratoryActive
  • >0.3 MΩ to 1 MΩ
40 ΩEmirates Engineering Calibration LaboratoryActive
  • >1 MΩ to 3 MΩ
0.18 kΩEmirates Engineering Calibration LaboratoryActive
  • >3 MΩ to 10 MΩ
1.1 kΩEmirates Engineering Calibration LaboratoryActive
  • >10 MΩ to 30 MΩ
7.9 kΩEmirates Engineering Calibration LaboratoryActive
  • >30 MΩ to 100 MΩ
47 kΩEmirates Engineering Calibration LaboratoryActive
  • >100 MΩ to 300 MΩ
0.79 MΩEmirates Engineering Calibration LaboratoryActive
  • >0.3 GΩ to 1.1 GΩ
12 MΩEmirates Engineering Calibration LaboratoryActive
Electrical-Source
  • DC Voltage
  • Direct Method using work instruction CM2-0 QA/DOC/050 based on Monograph 6 (NMI Australia)
  • Up to 330 mV
6.4 µVEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • >330 mV to 3.3 V
20 µVEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • >3.3 V to 33 V
0.22 mVEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • >33 V to 330 V
3.5 mVEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • >330 V to 1020 V
38 mVEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • AC Voltage @ 45Hz, 400 Hz, 1 kHz
  • Direct Method using work instruction CM2-0 QA/DOC/050 based on Monograph 6 (NMI Australia)
  • 1 mV to 33 mV
70 µVEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • >33 mV to 330 mV
300 µVEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • >0.33 V to 3.2 V
0.8 mVEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • >3.2 V to 33 V
7 mVEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • >33 V to 330 V
70 mVEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • >330 V to 1020 V
0.53 VEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • DC Current
  • 1 mA to 3.3 mA
0.082 µAEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • >3.3 mA to 33 mA
8.1 µAEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • >33 mA to 330 mA
0.11 mAEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • >0.33 A to 2.2 A
0.7 mAEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • >2.2 A to 11 A
12 mAEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • AC Current @ 50 Hz
  • Direct Method using work instruction CM2-0 QA/DOC/050 based on Monograph 6 (NMI Australia)
  • 1 mA to 3.3 mA
57 µAEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • >3.3 mA to 33 mA
7.3 mAEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • >33 mA to 330 mA
0.53 mAEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • >0.33 A to 2.2 A
2.0 mAEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • >2.2 A to 11 A
58 mAEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • DC Resistance
  • Direct Method using work instruction CM2-0 QA/DOC/050 based on Monograph 6 (NMI Australia)
  • 0.0 Ω
0.0025 ΩEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 1.0 Ω
0.0026 ΩEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 10 Ω
0.0033 ΩEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 100 Ω
0.11 ΩEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 1 kΩ
0.00010 kΩEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 10 kΩ
0.00090 kΩEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 100 kΩ
0.0086 kΩEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 1 MΩ
0.00010 MΩEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 10 MΩ
0.013 MΩEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 100 MΩ
0.63 MΩEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • Capacitance
  • Direct Method using work instruction CM2-0 QA/DOC/050 based on Monograph 6 (NMI Australia)
  • 0.1 nF
26 pFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 0.2 nF
27 pFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 0.3 nF
28 pFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 0.4 nF
30 pFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 1 nF
0.70 nFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 2 nF
0.70 nFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 3 nF
0.70 nFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 4 nF
0.70 nFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 10 nF
0.72 nFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 20 nF
0.88 nFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 30 nF
0.94 nFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 40 nF
1.0 nFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 0.1 μF
4.2 nFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 0.2 μF
6.8 nFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 0.3 μF
7.4 nFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 0.4 μF
8.1 nFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 1 μF
42 nFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 2 μF
67 nFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 3 μF
74 nFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 4 μF
80 nFEmirates Engineering Calibration Laboratory & Customer PremisesActive
  • 11 μF
0.76 μFEmirates Engineering Calibration Laboratory & Customer PremisesActive
Pressure
  • Gas Pressure (Absolute)/ Digital and analog indicating devices
  • Direct comparison with reference pressure calibrator using work instruction CM 3-0 based on DKD- R 6-1 (2014)
  • 75 kPa to 115 kPa
0.20 kPaEmirates Engineering Calibration LaboratoryActive
  • Gas Pressure (Gauge mode)/Digital and analog indicating devices
  • ­95 kPa to 7MPa
0.50 kPaEmirates Engineering Calibration LaboratoryActive
  • ­95 kPa to 4 Mpa
0.50 kPaEmirates Engineering Calibration Laboratory and Customer PremisesActive
  • Liquid Pressure (Gauge mode)/ Digital and analog indicating devices
  • 0 MPa to 100 MPa
21 kPa + 0.0090 % of ReadingEmirates Engineering Calibration LaboratoryActive
Torque
  • Torque / Hand Torque Tools
  • By using procedure CM 4 of QA/DOC/050 based on: ISO 6789-1:2017 and ISO 6789-2:2017, clockwise direction
  • 0.035 N·m to 0.71 Nm
0.039Emirates Engineering Calibration LaboratoryActive
  • 0.71 N·m to 340 N·m
1.0 %Emirates Engineering Calibration LaboratoryActive
  • 340 N·m to 813 N·m
0.8 %Emirates Engineering Calibration LaboratoryActive
  • 813 N·m to 2711 N·m
0.8 %Emirates Engineering Calibration LaboratoryActive
  • Torque / Calibration of Torque Meters & Transducers
  • Comparison Method using work instruction CM 4-1 of QA/DOC/050 based on BS 7882:2017
  • 0 N.m to 813 N.m (600 lbf.ft )
0.00032Emirates Engineering Calibration LaboratoryActive
Mass
  • Calibration of Aircraft weighing balance
  • Intercom Aircraft weighing machine calibration system
  • 5102.914 kgf to 10196.756 kgf (11250 lbf to 22480 lbf)
6.8 kgf to 26 kgf (15 lbf to 57 lbf)Emirates Engineering Calibration LaboratoryActive
Balance
  • Balance calibration
  • Calibration of non automatic weighing scales based on cg 18 using F1 masses
  • 100 mg to 200 g
1.1 mgCustomer PermesesActive
  • > 200 g to 600 g
0.010 gCustomer PermesesActive
  • > 600 g to 10 kg
0.053 gCustomer PermesesActive
  • > 10 kg to 100 kg
0.52 gCustomer PermesesActive
Dimensions
  • Vernier Caliper
  • Comparison to reference gauge block set according to Calibration QA/DOC/050,CM-10-0 base on NPL G40
  • 0 mm-150 mm
24 µmEmirates Engineering Calibration LaboratoryActive
  • Micrometers
  • Comparison to reference gauge block set according to Calibration QA/DOC/050,CM-10-0 base on NPL G40
  • 0 mm-25 mm
6.2 µmEmirates Engineering Calibration LaboratoryActive
  • Dial gauge
  • Comparison to reference dial gauge tester according to Calibration QA/DOC/050,CM-10-0 base on NPL G80
  • 0 mm-10 mm
5.8 µmEmirates Engineering Calibration LaboratoryActive
Temperature & Humidity
  • Thermo-Hygrometer
  • Direct comparison with reference of Temperature humidity chamber using calibration manual CM 13-1 based on DKD- R5-8
  • 20°C to 30°C 30 %RH to 70 %RH
0.24 °C 2.14 & RHEmirates Engineering Calibration LaboratoryActive
  • Temperature Sensor with Digital or Dial Indicator
  • Direct comparison with reference PRT using calibration manual CM 13-2 based on ASTM E2877
  • -40°C to 250°C
0.7 °CEmirates Engineering Calibration Laboratory and Customer PremisesActive
  • Climatic Chamber
  • Direct comparison with reference of Temperature scanner using calibration manual CM 13-3 based on EURAMET cg-20
  • -35°C to 250°C
2.6°CEmirates Engineering Calibration Laboratory and Customer PremisesActive