Emirates Safety Laboratory L.L.C

Initial Accreditation Date:Aug 03 , 2021

Contacts Info

Address

Dubai, United Arab Emirates

PO box / Zip Code

231908

Email

ask@emirateslaboratory.com

Website

www.emirateslaboratory.com

Main Field

Certification Bodies Products certification

Valid Since:Aug 03 , 2024

Certification Type/Scheme Product Category Type of Product Applicable Standard Status
Product Certification based on ISO/ IEC 17065
  • Type 3 UAE Fire and Life Safety Products (CS-COC -Version 04, dated 12 October 2021) - Ref: UAE Fire and Life Safety Code of Practice))
  • Fire and Life Safety Products
  • Construction (Ch.1) - Fire resistance rating of Fire Walls/ Fire Barriers (7.1.3)
ASTM E119, BS 476-21, BS 476-22, EN 1364-1, EN 1364-3, EN 1364-4, EN 1365-1, EN 1365-2, UL 263, UL 1709Active
  • Construction (Ch.1) - Interior Wall and Ceiling Finish materials and ceiling plenum assembly (7.1.4)
ASTM E119, BS 476-6, BS 476-7. EN 1364-2, EN 13501-1 (with EN 13823 and/or EN ISO 11925-2 and/or EN ISO 1182 and/or EN ISO 1716), FM 4880, NFPA 286, UL 1715Active
  • Construction (Ch.1) - Expanded Vinyl Wall coverings (7.1.5)
ASTM E84, UL 723, EN 13501-1 (with EN 13823 and/or EN ISO 11925-2 and/or EN ISO 1182 and/or EN ISO 1716), BS 476-6, BS 476-7, NFPA 265Active
  • Construction (Ch.1) – Interior Wall and Ceiling Coverings (7.1.6)
ASTM E84, EN 1364-2, EN 13501-1 (with EN 13823 and/or EN ISO 11925-2 and/or EN ISO 1182 and/or EN ISO 1716), BS 476-6, BS 476-7, NFPA 286, UL 723,Active
  • Construction (Ch.1) - Interior Floor and Floor Coverings (7.1.7)
ASTM E648, CAN/ULC-S102.2, CPSC 16 CFR 1630, EN 13501-1, NFPA 253Active
  • Construction - Combustible Decorative Materials (7.1.8)
BS 476-6, BS 476-7, CAN/ULC-S109, EN 13501-1 (with EN 13823 and/or EN ISO 11925-2 and/or EN ISO 1182 and/or EN ISO 1716), NFPA 701Active
  • Construction (Ch.1) - Textile Wall and Textile Ceiling Materials (7.1.9)
ASTM E84, BS 476-6, BS 476-7, EN 13501-1, UL 723Active
  • Construction (Ch.1) - Carpets and Textile floor finish (7.1.10)
ASTM E648, EN 13501-1 (with EN ISO 11925-2 and/or EN ISO 9239-1 and/or EN ISO 1182 and/or EN ISO 1716), NFPA 253, CAN/ULC-S102.2Active
  • Construction (Ch.1) - Thermal Barriers (7.1.11)
ASTM E119, UL 263, EN 1364-1, NFPA 275, UL 1040, UL 1715Active
  • Construction (Ch.1) - Through–penetration Firestop System (7.1.12)
ASTM E814, EN 1366-3, UL 1479, UL 263Active
  • Construction (Ch.1) - Fire resistant Joint System (7.1.13)
ASTM E1966, EN 1366-4, UL 2079,Active
  • Construction (Ch.1) - Membrane Fire stop System (7.1.14)
ASTM E814, EN 1366-3, EN 1366-4, UL 263, UL 1479Active
  • Construction (Ch.1) - Fire resistance rated Glazing in Doors and Walls (7.1.15)
ASTM E119, UL 263, EN 1364-1, EN 1634-1, BS 476-22, UL 10BActive
  • Construction (Ch.1) - Fire retardant coatings (7.1.16)
ASTM E2768, EN 13381-4, EN 13381-8Active
  • Construction (Ch.1) – Perimeter fire barrier system/Exterior curtain wall/floor intersection (7.1.17)
ASTM E2307, EN 1364-3, EN 1364-4Active
  • Construction (Ch.1) – Glazing in door assembly (7.1.18)
EN 1634-1, BS 476-22, NFPA 252, UL 10B, UL 10CActive
  • Construction (Ch.1) – Plastic skylights on roof assembly (7.1.19)
ASTM E84, BS 476-7, EN 13501-1, EN 13501-5 (with CEN/TS 1187), UL 723, ANSI/UL 790Active
  • Construction (Ch.1) – Roof Assemblies (exterior fire exposure) (7.1.20)
EN 13501-5 with CEN/TS 1187, FM 4470, FM 4471Active
  • Construction (Ch.1) – Roof Assemblies (interior fire exposure) (7.1.21)
UL 1256, FM 4471Active
  • Construction (Ch.1) – Roof Coverings (7.1.22)
ASTM E108, EN 13501-5 (with CEN/TS 1187), FM 4470, ANSI/UL 790, UL 1256Active
  • Construction (Ch.1) – Foam Plastic used in freezer rooms (7.1.23)
ASTM D1929Active
  • Construction (Ch.1) – Factory manufactured of prefabricated panels with foam plastic insulation (7.1.24)
NFPA 285, EN 13501-1 (with EN 13823 and/or EN ISO 11925-2 and/or EN ISO 1182 and/or EN ISO 1716)Active
  • Construction (Ch.1) – MCM/ACP and core (7.1.25)
ASTM D1929, BS 8414-1, BS 8414-2, BR 135, EN 13501-1, NFPA 285Active
  • Construction (Ch.1) – MCM and ACP Panel Wall Systems as Assembly (7.1.26)
ASTM D1929, ASTM E119, EN 1364-3, EN 1364-4, EN 13501-1, UL 263Active
  • Construction (Ch.1) – EIFS/ETICS (7.1.27)
ASTM E84, BS 8414-1, BS 8414-2, BR 135, EN 1364-3, EN 1364-4, NFPA 268, NFPA 285, ASTM E119, UL 263, UL 723Active
  • Construction (Ch.1) – PEWFS Wall System (7.1.28)
ASTM D1929, ASTM E119, BS 8414-1, BS 8414-2, BR 135, EN 1364-3, EN 1364-4, EN 13501-1, NFPA 285, UL 263Active
  • Construction (Ch.1) – Sandwich Panel (7.1.29)
ASTM E84, ASTM E108, ASTM E119, ASTM D1929, BS 476-7, BS 8414-1, BS 8414-2, BR 135, EN 1364-3, EN 1364-4, EN 13501-1, EN 13501-5, FM 4470, FM 4471, FM 4880, NFPA 285, UL 263, UL 723, ANSI/UL 790, UL 1715Active
  • Construction (Ch.1) – Door Assemblies (7.1.30)
BS 476-22, EN 1634-1, EN 1364-1, NFPA 252, UL 10B, UL 10CActive
  • Construction (Ch.1) – Window Assemblies (7.1.31)
ASTM E119, EN 1634-1, NFPA 257, UL 9Active
  • Construction (Ch.1) – Upholstered furniture (7.1.32)
ASTM E1537, BS 5852, EN 1021-1, EN 1021-2Active
  • Construction (Ch.1) – Fire dampers (7.1.33)
EN 13501-3, EN 1366-2, ANSI/UL 555Active
  • Construction (Ch.1) – Combination (Fire/Smoke) Damper (7.1.34)
ANSI/UL 555, ANSI/UL 555S, EN 1366-10, EN 13501-4Active
  • Construction (Ch.1) – Glazing System on non-load bearing wall / Curtain wall system (7.1.35)
ASTM E119, BS 476-22, EN 1364-1, EN 1364-3, UL 263Active
  • Construction (Ch.1) – Glazing System on load bearing floor/roof (7.1.36)
ASTM E119, BS 476-21, EN 1365-2, UL 263Active
  • Construction (Ch.1) – Safety glazing (7.1.37)
ANSI Z97.1, CPSC 16 CFR 1201, EN 12600Active
  • Construction – Structural steelwork (7.1.38, 7.1.39)
BS 476-21 (with BS 476-20), BS 476-23 (with BS 476-20), EN 1363-1, EN 1363-2, EN 1365-3, EN 1365-4, EN 13381-4, EN 13381-8Active
  • Construction (Ch.1) – Kiosks (7.1.40)
NFPA 701Active
  • Construction (Ch.1) – Membrane structure (7.1.41)
ASTM E84, BS 476-7, EN 13501-1, NFPA 701, UL 723Active
  • Construction (Ch.1) – Tents (7.1.42)
ASTM E84, BS 476-7, EN 13501-1, NFPA 701, UL 723Active
  • Construction (Ch.1) – Advertising Billboards (using combustible materials) (7.1.44)
NFPA 701, ASTM E84, NFPA 265, UL 723Active
  • Construction (Ch.1) – Non-combustible Material for Cavity Fire Barrier (groove sealants, gaskets, back backer rod and vapour barrier systems) (7.1.45)
BS 476-4, EN 13501-1, EN ISO 1182Active
  • Construction (Ch.1) - Modular Homes/Offices (7.1.46)
ASTM E84, FM 4880, UL 723Active
  • Construction (Ch.1) – GRC / GRFC / GRP Panels (7.1.47)
ASTM E119, ASTM D1929, EN 13501-1, BS 8414-1, BS 8414-2 , BR 135, EN 1364-3, EN 1364-4, UL 263Active
  • Means of egress (Ch.3) – Fire resistance rated door assemblies (7.1.3)
EN 16034, EN 1634-1, EN 1634-2, EN 1634-3, NFPA 252, UL 10B, UL 10C, UL 1784Active
  • Means of egress (Ch.3) – Fire resistance rated window assemblies (7.1.7)
EN 1634-1, EN 1634-2, EN 1634-3, UL 9, NFPA 257, UL 1784Active
  • Means of egress (Ch.3) – Fire resistance rated glazing in doors and walls (7.1.8)
ASTM E119, BS 476-22, EN 1364-1, EN 1634-1, UL 10B, UL 10C, UL 263Active
  • Means of egress (Ch.3) – Glazing in door assembly (7.1.9)
EN 1634-1, ISO 3009, NFPA 252, UL 10B, UL 10CActive
  • Means of egress (Ch.3) – Safety glazing (7.1.10)
ANSI Z97.1, CPSC 16 CFR 1201, EN 12600Active
  • Means of egress (Ch.3) – Upholstered furniture (7.1.11)
ASTM E1537, ASTM E1353, BS 5852, EN 1021-1, EN 1021-2Active
  • Means of egress (Ch.3) – Combustible decorative materials (7.1.12)
BS 476-6, CAN/ULC-S109, EN ISO 6940, EN ISO 6941, EN 13501-1 (with EN 13823 and/or EN ISO 11925-2 and/or EN ISO 1182 and/or EN ISO 1716), NFPA 701Active
  • Means of egress (Ch.3) – Carpets and textile floor finish (7.1.13)
ASTM E648, EN 1365-2, EN 1366-6, EN 13501-1 (with EN ISO 11925-2 and/or EN ISO 9239-1 and/or EN ISO 1182 and/or EN ISO 1716), CAN/ULC-S102.2, NFPA 253Active
  • Means of egress (Ch.3) – Kiosks (7.1.14)
NFPA 701Active
  • Means of egress (Ch.3) – Exhibit booth (7.1.16)
NFPA 701, NFPA 703Active
  • Means of egress (Ch.3) – Mattresses (7.1.17)
ASTM D1929, ASTM E84, ASTM E1590, CPSC 16 CFR 1632, BS 6807, BS 7175, EN 597-1, EN 597-2, EN 13501-1, UL 723Active
  • Emergency lighting (Ch.6) - Fire rated cable (8.1.9)
BS 8434-2, EN 50200, IEC 60331-1, IEC 60331-2, IEC 60332-2-2, UL 1685, UL 1666, UL 1724, UL 2196Active
  • Emergency voice evacuation systems (Ch.7) - Fire rated cable (6.1.7)
BS 8434-2, EN 50200, IEC 60331-1, IEC 60331-2, IEC 60332-2-2, UL 1724, UL 1685, UL 1666, UL 2196Active
  • Fire detection and alarm systems (Ch.8) - Fire rated cable (7.1.23)
BS 8434-2, EN 50200, IEC 60331-1, IEC 60331-2, IEC 60332-2-2, UL 1724, UL 1685, UL 1666, UL 2196Active
  • Fire protection systems (Ch.9) - Fire rated cable (6.1.29)
BS 8434-2, EN 50200, IEC 60331-1, IEC 60331-2, IEC 60332-2-2, UL 1724, UL 1685, UL 1666, UL 2196Active
  • Smoke control and management systems (Ch.10) – Smoke damper (6.1.3)
ANSI/UL 555S, EN 12101-8, EN 1366-10Active
  • Smoke control and management systems (Ch.10) – Fire damper (6.1.4)
ANSI/UL 555, EN 13501-3, EN 1366-2Active
  • Smoke control and management systems (Ch.10) – Combination (Fire/Smoke) Damper (6.1.5)
ANSI/UL 555,Active
  • Smoke control and management systems (Ch.10) – Smoke Curtains or Draft Curtains (6.1.7)
ANSI/UL 555S, EN 12101-8, EN 1366-2, EN 1366-10, EN 12101-1Active
  • Smoke control and management systems (Ch.10) – Fire curtains (6.1.8)
BS 476-22, EN 1634-1, UL 10DActive
  • Smoke control and management systems (Ch.10) – Natural Smoke and Heat Vents (6.1.9)
EN 12101-2Active
  • Smoke control and management systems (Ch.10) – Mechanical Extract Fans and Jet Fans (6.1.10)
EN 12101-3, EN 13501-4Active
  • Smoke control and management systems (Ch.10) – Powered Smoke and Heat Exhaust Ventilators (6.1.11)
EN 12101-3, EN 13501-4Active
  • Smoke control and management systems (Ch.10) – Ducts for Smoke control system (6.1.12)
ASTM E2816, BS 476-24, EN 1366-1, EN 1366-8, EN 1366-9, EN 12101-7, EN 13501-4, ANSI/UL 181Active
  • Smoke control and management systems (Ch.10) – Duct and Pipe Insulation (as assembly including Pipe and Duct insulation, coverings) (6.1.13)
NFPA 274Active
  • Smoke control and management systems (Ch.10) – Air Filters (6.1.15)
ANSI/UL 900Active
  • Smoke control and management systems (Ch.10) - Fire rated cable (6.1.17)
BS 8434-2, EN 50200, IEC 60331-1, IEC 60331-2, IEC 60332-2-2, UL 1724, UL 1685, UL 1666, UL 2196Active
BS 8434-2, EN 50200, IEC 60331-1, IEC 60331-2, IEC 60332-2-2, UL 1724, UL 1685, UL 1666, UL 2196Active
  • Utility occupancies (Ch.14) - PV cells integrated into building (BIPV) material to be installed on roof of Midrise and Highrise buildings (2.2.4.4)
ANSI/UL 790, ASTM E108, EN 13501-5Active
  • Utility occupancies (Ch.14) - PV cells (BAPV) to be installed on façade (2.2.4.5)
EN 13501-1Active
  • Utility occupancies (Ch.14) - PV systems (BAPV) or (BIPV), as façade system to be installed on façade (2.2.4.6)
EN 13501-1, ASTM D1929, BS 8414-1, BS 8414-2, BR 135, NFPA 285Active