Directory Details

Interface Technical Inspection

Initial Accreditation Date:Aug 15 , 2013

Contacts Info

Address

RAs Al Khor Industrial Area II, Dubai, United Arab Emirates

PO box / Zip Code

78921

Email

iti@eim.ae info@itindt.ae

Website

http://www.itindt.ae/inspection-services/

Phone No.

+971 04 333 6311

Mobile No.

+971 04 333 6312

Main Field

Inspection Bodies

Valid Since:Sep 14 , 2022

Inspection Category Inspection field Range of inspection Stage of Inspection Inspection criteria Inspection Activity Type Status
Non-Destructive Testing
  • Product
  • Structural Engineering of Welds, Materials and pressure parts
  • Magnetic particle examination (MT) - Visual
  • New construction
ASME Section VAActive
  • Magnetic particle examination (MT) - Fluorescent
ASME Section VAActive
  • Magnetic particle examination (MT) - Visual
  • In-service
ASME Section VAActive
  • Magnetic particle examination (MT) - Fluorescent
ASME Section VAActive
  • Magnetic particle examination (MT) - Visual
  • New construction
BS EN ISO 17638AActive
  • Magnetic particle examination (MT) - Fluorescent
BS EN ISO 17638AActive
  • Magnetic particle examination (MT) - Visual
  • In-service
BS EN ISO 17638AActive
  • Magnetic particle examination (MT) - Fluorescent
BS EN ISO 17638AActive
  • Magnetic particle examination (MT) - Visual
  • New construction
AWS D1.1/D1.1MAActive
  • Magnetic particle examination (MT) - Fluorescent
AWS D1.1/D1.1MAActive
  • Magnetic particle examination (MT) - Visual
  • In-service
AWS D1.1/D1.1MAActive
  • Magnetic particle examination (MT) - Fluorescent
AWS D1.1/D1.1MAActive
  • Ultrasonic Testing -Flaw detection
  • New construction
ASME Sec. VAActive
  • In-service
ASME Sec. VAActive
  • New construction
AWS D1.1/D1.1MAActive
  • In-service
AWS D1.1/D1.1MAActive
  • New construction
BS/EN ISO 17640AActive
  • In-service
BS/EN ISO 17640AActive
  • Radiographic examination (RT)
  • New construction
ASME Sec. VAActive
  • In-service
ASME Sec. VAActive
  • New construction
AWS D1.1/D1.1MAActive
  • In-service
AWS D1.1/D1.1MAActive
  • New construction
BS/EN ISO 17636-1AActive
  • In-service
BS/EN ISO 17636-1AActive
  • New construction
BS/EN ISO 17636-2AActive
  • In-service
BS/EN ISO 17636-2AActive
  • Dye penetrant inspection - Visual
  • New construction
ASME Section VAActive
  • Dye penetrant inspection - Fluorescent
ASME Section VAActive
  • Dye penetrant inspection - Visual
  • In-service
ASME Section VAActive
  • Dye penetrant inspection - Fluorescent
ASME Section VAActive
  • Dye penetrant inspection - Visual
  • New construction
AWS D1.1/D1.1MAActive
  • Dye penetrant inspection - Fluorescent
AWS D1.1/D1.1MAActive
  • Dye penetrant inspection - Visual
  • In-service
AWS D1.1/D1.1MAActive
  • Dye penetrant inspection - Fluorescent
AWS D1.1/D1.1MAActive
  • Dye penetrant inspection - Visual
  • New construction
BS EN ISO 3452- 1AActive
  • Dye penetrant inspection - Fluorescent
BS EN ISO 3452- 1AActive
  • Dye penetrant inspection - Visual
  • In-service
BS EN ISO 3452- 1AActive
  • Dye penetrant inspection - Fluorescent
BS EN ISO 3452- 1AActive
  • Phased Array Ultrasonic Testing (PAUT)
  • New construction
ASME SEC VAActive
  • In-service
ASME SEC VAActive
  • New construction
BSEN ISO 13588AActive
  • In-service
BSEN ISO 13588AActive
  • Visual Examination (VT) Direct and Remote
  • New construction
ASME SECTION VAActive
  • In-service
ASME SECTION VAActive
  • New construction
BSENISO 17637AActive
  • In-service
BSENISO 17637AActive
  • Ultrasonic Testing -Flaw Detection -Time-of-flight Diffraction (TOFD)
  • New construction
ASME SECTION VAActive
  • In-service
ASME SECTION VAActive
  • New construction
BSENISO 10863AActive
  • In-service
BSENISO 10863AActive