Directory Details

Inkal Technical Solutions LLC

Initial Accreditation Date:Mar 06 , 2016

Contacts Info

Address

33/15 Mussaffah, Al Kawakib 8th street, Abu Dhabi, Abu Dhabi, United Arab Emirates

PO box / Zip Code

90905

Email

qc@inkal.ae qc@arabcal.com

Website

www.arabcal.com

Phone No.

+971 055 221 0154

Mobile No.

+971 02 557 6864

Main Field

Calibration Laboratories

Valid Since:Mar 17 , 2025

Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Balance & Scale
  • Top loading weighing scale
Active
Electrical
  • DC Voltage Calibration of meters
  • CI/01/M1 Based on Euramet cg-15 U: Voltage Measured value
  • 0.001 V up to 0.2 V
57 X 10-6U + 5.0 µVLaboratoryActive
  • > 0.2 V up to 2 V
57 X 10-6U + 41 µVLaboratoryActive
  • > 2 V up to 20 V
57 X 10-6U + 0.36 mVLaboratoryActive
  • > 20 V up to 200 V
57 X 10-6U + 3.6 mVLaboratoryActive
  • > 200 V up to 1025 V
57 X 10-6U + 23 mVLaboratoryActive
  • AC Voltage Calibration of meters
  • CI/01/M1 Based on Euramet cg-15 U: Measured Voltage value
  • (0.001 V to 0.2 V) 45 Hz up to 1.999 kHz
0.33 X 10-3U + 52 µVLaboratoryActive
  • (0.001 V to 0.2 V) 2 kHz up to 19.999 kHz
1.2 X 10-3U + 0.23 mVLaboratoryActive
  • (> 0.2 V up to 2 V) 45 Hz up to 1.999 kHz
0.38 X 10-3U + 0.34 mVLaboratoryActive
  • (> 0.2 V up to 2 V) 2 kHz up to 19.999 kHz
0.65 X 10-3U + 0.59 mVLaboratoryActive
  • (> 2 V up to 20 V) 45 Hz up to 1.999 kHz
0.38 X 10-3U +3.4 mVLaboratoryActive
  • (> 2 V up to 20 V) > 2 kHz up to 19.999 kHz
0.77 X 10-3U + 5.8 mVLaboratoryActive
  • (> 20 V up to 200 V) 40 Hz up to 1.999 kHz
0.49 X 10-3U + 33 mVLaboratoryActive
  • (> 20 V up to 200 V) 2 kHz up to 20 kHz
1.1 X 10-3U + 50 mVLaboratoryActive
  • (> 200 V up to 1025 V) 40 Hz up to 1.999 kHz
0.49 X 10-3I + 0.19 VLaboratoryActive
  • (> 200 V up to 1025 V) > 2 kHz up to 10 kHz
1.1 X 10-3I + 0.38 VLaboratoryActive
  • DC Current Calibration of meters
  • CI/01/M1 Based on Euramet cg-15 I : Measured Current value
  • 0.000 µA up to 200 µA
0.14 X 10-6I+ 23 nALaboratoryActive
  • > 0.2 mA up to 2 mA
0.12 X 10-6I + 55 nALaboratoryActive
  • > 2 mA up to 20 mA
0.12 X 10-6I + 1.0 µALaboratoryActive
  • > 20 mA up to 200 mA
0.14 X 10-3I + 9.3 µALaboratoryActive
  • > 0.2 A up to 2 A
0.57 X 10-3I + 0.13 mALaboratoryActive
  • > 2 A up to 20 A
0.57 X 10-3I + 1.2 mALaboratoryActive
  • DC Current Calibration of Meters (Current coil method 10-turn & 50-turn)
  • CI/01/C6 Based on Euramet cg-15 I : Measured Current value
  • 20 A up to 100 A
16 X 10-3ILaboratoryActive
  • > 100 A up to 500 A
11 X 10-3ILaboratoryActive
  • > 500 A up to 1000 A
6.6 X 10-3ILaboratoryActive
  • AC Current Calibration of meters
  • CI/01/M1 Based on Euramet cg-15 I: Measured Current value
  • (2.5 µA up to 200 µA) 45 Hz up to 1.999 kHz
0.81 X 10-3I + 0.35 µALaboratoryActive
  • (> 0.2 mA up to 2 mA) 45 Hz up to 1.999 kHz
0.77 X 10-3I + 1.0 µALaboratoryActive
  • (> 2 mA up to 20 mA) 45 Hz up to 1.999 kHz
0.77 X 10-3I + 5.0 µALaboratoryActive
  • (> 20 mA up to 200 mA) 45 Hz up to 1.999 kHz
0.77 X 10-3I + 50 µALaboratoryActive
  • (> 0.2 A up to 2 A) 45 Hz up to 2 kHz
0.67 X 10-3I + 1.8 mALaboratoryActive
  • (> 2 A up to 20 A) 45 Hz up to 200 Hz
1.7 X 10-3I + 8.2 mALaboratoryActive
  • AC Current Calibration of Meters (Current coil method 10-turn & 50-turn)
  • CI/01/C6 Based on Euramet cg-15 I: Measured Current value
  • (20 A up to 100 A) 30 Hz up to 60 Hz
16 X 10-3ILaboratoryActive
  • (> 100 A up to 500 A) 30 Hz up to 60 Hz
13 X 10-3ILaboratoryActive
  • (> 500 A to 1000 A) 30 Hz to 60 Hz
6.6 X 10-3ILaboratoryActive
  • Capacitance Calibration of Meters
  • CI/01/M1 Based on Euramet cg-15
  • 10 nF
58 pFLaboratoryActive
  • 20 nF
0.10 nFLaboratoryActive
  • 50 nF
0.24 nFLaboratoryActive
  • 100 nF
0.48 nFLaboratoryActive
  • 1 uF
10 nFLaboratoryActive
  • Frequency
  • CI/01/M1 Based on Euramet cg-15 f :Measured Frequency Value
  • 1 Hz up to 99 Hz
2.0 X 10-6f+ 18 µHzLaboratoryActive
  • 100 Hz up to 999 Hz
2.0 X 10-6f+ 90 µHzLaboratoryActive
  • 1 kHz up to 9.999 kHz
2.0 X 10-6f+ 0.90 mHzLaboratoryActive
  • 10.000 kHz up to 19.999 kHz
2.0 X 10-6f+ 0.59 mHzLaboratoryActive
  • 20.000 kHz up to 49.999 kHz
2.0 X 10-6f+ 1.8 mHzLaboratoryActive
  • 50000 kHz up to 99.999 kHz
2.0 X 10-6f+ 30 mHzLaboratoryActive
  • 100.000 kHz up to 999.999 kHz
2.0 X 10-6f+ 91 mHzLaboratoryActive
  • 1 MHz up to 10 MHz
2.0 X 10-6f+ 0.90 HzLaboratoryActive
  • Resistance Calibration of Meters 2-wire
  • CI/01/M1 Based on Euramet cg-15
  • 0.2 Ω
9.0 mΩLaboratoryActive
  • 10 Ω
13 mΩLaboratoryActive
  • 100 Ω
18 mΩLaboratoryActive
  • 1 kΩ
0.12 ΩLaboratoryActive
  • 10 kΩ
1.2 ΩLaboratoryActive
  • 100 kΩ
12 ΩLaboratoryActive
  • 1 MΩ
0.22 kΩLaboratoryActive
  • 10 MΩ
7.4 kΩLaboratoryActive
  • 100 MΩ
0.13 MΩLaboratoryActive
  • Resistance Calibration of Meters 4-wire
  • 0.1 Ω
4.5 mΩLaboratoryActive
  • 10 Ω
13 mΩLaboratoryActive
  • 100 Ω
17 mΩLaboratoryActive
  • 1 kΩ
0.12 ΩLaboratoryActive
  • 10 kΩ
1.2 ΩLaboratoryActive
  • 100 kΩ
12 ΩLaboratoryActive
  • Insulation Resistance Calibration of Meters
  • CI/01/I2 Based on SANAS guideline:TG-02-01
  • 10 MΩ
80 kΩLaboratoryActive
  • 100 MΩ
0.62 MΩLaboratoryActive
  • 1 GΩ
60 MΩLaboratoryActive
  • 10 GΩ
0.10 GΩLaboratoryActive
  • DC Voltage (Above 1000 V) Calibration of Meters
  • CI/01/I2 Based on SANAS guideline:TG-02-01 U=measured value
  • > 1000 V to 2500 V
33 VLaboratoryActive
  • > 2500 V to 5000 V
63 VLaboratoryActive
  • AC Voltage @ 60 Hz (Above 1000 V) Calibration of Meters
  • CI/01/I2 Based on SANAS guideline:TG-02-01
  • > 1000 V to 2500 V
0.15 kVLaboratoryActive
  • > 2500 V to 5000 V
0.34 kVLaboratoryActive
Energy Measurement
  • Active Energy (Offline)
  • Direct Method Based on EN50470 E: Measured value
  • (• Voltage: 30 V to 500 V, • Frequency: 40 Hz to 65 Hz, • Power Factor: Cos Φ= 1 to 0.5 (Lead and Lag)) 10 mA to 12 A (Cos Φ = 1)
0.07 % ELaboratory and Customer PremiseActive
  • (• Voltage: 30 V to 500 V, • Frequency: 40 Hz to 65 Hz, • Power Factor: Cos Φ= 1 to 0.5 (Lead and Lag)) 10 mA to 12 A (Cos Φ = 0.5 to <1)
0.08 % ELaboratory and Customer PremiseActive
  • (• Voltage: 30 V to 500 V, • Frequency: 40 Hz to 65 Hz, • Power Factor: Cos Φ= 1 to 0.5 (Lead and Lag)) >12 A to 120 A (Cos Φ = 0.5 to 1)
0.08 % ELaboratory and Customer PremiseActive
  • Reactive Energy (Offline)
  • Direct Method Based on EN50470 Er: Measured value
  • (• Voltage: 30 V to 500 V, • Frequency: 40 Hz to 65 Hz, • Power Factor: Sin Φ= 1 to 0.5 (Lead and Lag)) 10 mA to 12 A (Sin Φ = 1)
0.08 % ErLaboratory and Customer PremiseActive
  • (• Voltage: 30 V to 500 V, • Frequency: 40 Hz to 65 Hz, • Power Factor: Sin Φ= 1 to 0.5 (Lead and Lag)) 10 mA to 12 A (Sin Φ = 0.5 to <1)
0.08 % ErLaboratory and Customer PremiseActive
  • (• Voltage: 30 V to 500 V, • Frequency: 40 Hz to 65 Hz, • Power Factor: Sin Φ= 1 to 0.5 (Lead and Lag)) >12 A to 120 A (Sin Φ = 0.5 to 1)
0.08 % ErLaboratory and Customer PremiseActive
  • Active Energy (Online) Measurement of V, I, PF as set by the Customer
  • Direct Method using Current Clamp Based on EN50470 E: Measured value
  • (• Voltage: 30 V to 500 V, • Frequency: 40 Hz to 65 Hz, • Power Factor: Cos Φ:= 1 to 0.5 (Lead and Lag)) 10 mA to 12 A (Cos Φ = 1)
0.24 % ECustomer PremiseActive
  • (• Voltage: 30 V to 500 V, • Frequency: 40 Hz to 65 Hz, • Power Factor: Cos Φ:= 1 to 0.5 (Lead and Lag)) 10 mA to 12 A (Cos Φ = 0.5 to <1)
0.24 % ECustomer PremiseActive
  • (• Voltage: 30 V to 500 V, • Frequency: 40 Hz to 65 Hz, • Power Factor: Cos Φ:= 1 to 0.5 (Lead and Lag)) >12 A to 120 A (Cos Φ = 0.5 to 1)
0.24 % ECustomer PremiseActive
  • Reactive Energy (Online) Measurement of V, I, PF as set by the Customer
  • Direct Method using Current Clamps Based on EN50470 Er: Measured value
  • (• Voltage: 30 V to 500 V, • Frequency: 40 Hz to 65 Hz, • Power Factor: Sin Φ:= 1 to 0.5 (Lead and Lag)) 10 mA to 12 A (Sin Φ = 1)
0.24 % ErCustomer PremiseActive
  • (• Voltage: 30 V to 500 V, • Frequency: 40 Hz to 65 Hz, • Power Factor: Sin Φ:= 1 to 0.5 (Lead and Lag)) 10 mA to 12 A (Sin Φ = 0.5 to <1)
0.24 % ErCustomer PremiseActive
  • (• Voltage: 30 V to 500 V, • Frequency: 40 Hz to 65 Hz, • Power Factor: Sin Φ:= 1 to 0.5 (Lead and Lag)) >12 A to 120 A (Sin Φ = 0.5 to 1)
0.24 % ErCustomer PremiseActive
Dimensions
  • All types of Caliper Digital / Dial / Vernier
  • Procedure (CI/05/V3) based on ISO 13385-1-2019
  • Up to 600 mm
20 μmLaboratoryActive
  • External Micrometer (Digital & Analogue)
  • Procedure (CI/05/O2) based on ISO 3611 :2010
  • 0 to 25 mm
3.0 μmLaboratoryActive
  • Dial gauges (Digital & Analogue)
  • Procedure (CI/05/D6) based on ASME B 89-1.10 M-2001 with limited number of calibration points.
  • Up to 50 mm
4.0 μmLaboratoryActive
Mass and Balance
  • Non-automatic Weighing Instruments
  • CI/04/W1 in accordance to Euramet cg.18(V 4.0)
  • Upto 15 kg
2.6 x 10-5 FS of UUCCustomer PremisesActive
  • >15 kg to 250 kg
4 x 10-4 FS of UUCCustomer PremisesActive
Temperature & Humidity
  • Direct reading thermometers/Transmitters/Controllers/Temperature chart recorders
  • CI/10/T3 DKD R5-1-2003
  • -20 °C to 300°C
0.3°CLaboratory/ Customer PremisesActive
  • >300 °C to 600 °C
1.3 °CLaboratory/ Customer PremisesActive
  • Electrical Calibration of Temperature Indicators Indicators for TC type K
  • CI/03/ECT1 euramet cg-11
  • -270 °C to 1300 °C
0.59 °CLaboratory/ Customer PremisesActive
  • Electrical Calibration of Temperature Indicators Indicators for TC type J
  • -210 °C to 1200 °C
0.48 °CLaboratory/ Customer PremisesActive
  • Electrical Calibration of Temperature Indicators Indicators for TC type T
  • -270 °C to 400 °C
0.48 °CLaboratory/ Customer PremisesActive
  • Electrical Calibration of Temperature Indicators Indicators for TC type R
  • -50 °C to 1340 °C
0.82 °CLaboratory/ Customer PremisesActive
  • Electrical Calibration of Temperature Indicators Indicators for TC type S
0.93 °CLaboratory/ Customer PremisesActive
  • Electrical Calibration of Temperature Indicators Indicators for TC type N
  • -270 °C to 1300 °C
0.59 °CLaboratory/ Customer PremisesActive
  • Electrical Calibration of Temperature Indicators Indicators for TC type E
  • -270 °C to 1372 °C
0.49 °CLaboratory/ Customer PremisesActive
  • Electrical Calibration of Temperature Indicators Indicators for RTDs
  • -200 °C to 850 °C
0.39 °CLaboratory/ Customer PremisesActive
Pressure
  • Pneumatic Pressure (Gauge Pressure)
  • CI-02-PI2, BS 837-1 EURAMET /cg-17/v.04 DKD-R 6-1
  • -90 kPa to 250 kPa
0.26 kPaLaboratoryActive
  • >250 kPa to 20 MPa
3 kPaLaboratoryActive
  • Hydraulic Pressure (gauge pressure)
  • 0 to 70 MPa
30 kPaLaboratory/ Customer PremisesActive