Al Hoty-Stanger Laboratories

Initial Accreditation Date:Apr 16 , 2024

Contacts Info

Address

Abu Dhabi, United Arab Emirates

PO box / Zip Code

NA

Email

atiq@alhotystanger.ae

Website

NA

Main Field

Calibration Laboratories

Valid Since:Jul 02 , 2025

Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Balance & Scale
  • Top loading weighing scale
Active
Balance
  • Weighing Scales
  • SOP/02:2014 rev.2 "Calibration of Non-automatic Weighing Machines" according to EURAMET cg 18 (2015)
  • 1mg to 500mg
0.3mgCustomer PremisesActive
  • Up to 6kg
4.0mgCustomer PremisesActive
  • Up to 30kg
34.0mgCustomer PremisesActive
  • Up to 60kg
0.2gCustomer PremisesActive
Force
  • Force Verification/ Calibration of Universal testing machines (Tension)
  • SOP/01/rev.3/2020 "Calibration of Force Measuring Systems" Comparison method using force proving instruments based on BS EN ISO 7500-1:2018
  • 100 kN to 400 kN
0.53 % of indicator readingCustomer PremisesActive
  • >400 kN to 2000 kN
0.30 % of indicator readingCustomer PremisesActive
  • Force Verification/ Calibration of Compression testing machines
  • 60 kN to 100 kN
1.3 % of indicator reading for increasing forcesCustomer PremisesActive
  • >100 kN to 150 kN
0.57 % of indicator reading for increasing forcesCustomer PremisesActive
  • >150 kN to 250 kN
0.39 % of indicator reading for increasing forcesCustomer PremisesActive
  • >250 kN to 400 kN
0.27 % of indicator reading for increasing forcesCustomer PremisesActive
  • >400 kN to 500 kN
0.22 % of indicator reading for increasing forcesCustomer PremisesActive
  • >500 kN to 600 kN
0.20 % of indicator reading for increasing forcesCustomer PremisesActive
  • >600 kN to 3000 kN
0.30 % of indicator reading for increasing forcesCustomer PremisesActive
Temperature
  • Liquid-in-glass thermometers
  • SOP-04
  • -20 °C – 150 °C
0.1 °CLaboratory PremisesActive
  • Direct reading thermometers with RTD sensor
  • SOP-05
0.1 °CLaboratory PremisesActive
  • >150 °C – 500 °C
0.8 °CLaboratory PremisesActive
  • Direct reading thermometers with TC sensor
  • SOP-07
  • -20 °C – 150 °C
0.3 °CLaboratory PremisesActive
  • >150 °C – 500 °C
0.8 °CLaboratory PremisesActive
  • Dial Thermometers
  • SOP-06
  • -20 °C – 150 °C
0.1 °CLaboratory PremisesActive
  • >150 °C – 500 °C
0.8 °CLaboratory PremisesActive
  • IR thermometers
  • SOP-08
  • -35 °C – 100 °C
1.5 °CLaboratory PremisesActive
  • >100 °C – 150 °C
2.0 °CLaboratory PremisesActive
  • Climatic Chambers (also Ovens, Freezers, Chillers, Incubators) (9 sensors)
  • SOP-09
  • -80 °C – 5 °C
1.0 °CCustomers PremisesActive
  • >5 °C – 110 °C
0.6 °CCustomers PremisesActive
  • >110 °C – 400 °C
1.1 °CCustomers PremisesActive
  • Liquid baths (5 sensors)
  • SOP-10
  • -80 °C – 5 °C
0.7 °CCustomers PremisesActive
  • >5 °C – 95 °C
0.4 °CCustomers PremisesActive
  • >95 °C – 200 °C
0.7 °CCustomers PremisesActive
  • Muffle furnace (1 sensor)
  • SOP-11
  • 200 °C – 500 °C
0.9 °CCustomers PremisesActive
  • >500 °C – 800 °C
2 °CCustomers PremisesActive
  • >800 °C – 1200 °C
10 °CCustomers PremisesActive
  • Autoclaves (temperature indicator)
  • SOP-12
  • 50 °C - 100 °C
0.4 °CCustomers PremisesActive
  • >100 °C – 140 °C
0.7 °CCustomers PremisesActive
  • Base metal thermocouples
  • SOP-07
  • -20 °C – 150 °C
0.3 °CLaboratory PremisesActive
  • >150 °C – 500 °C
0.8 °CLaboratory PremisesActive
  • Thermo hygrometer
  • Internal Procedure - SOP 028 (comparison using Humidity generator)
  • 10 ⁰C to 50 ⁰C
0.5 ⁰CLaboratoryActive
  • 10% RH to 95% RH
1.2 % RHLaboratoryActive
Pressure
  • Gas Pressure (gauge)/ Digital and analogue indicating devices
  • SOP/03: 2018 rev. 1 "Calibration of pressure gauges" acc. to DKD-R 6-1 (03/2014)
  • -0.85 bar to 0 bar
0.30 % F.S.Laboratory PremisesActive
  • 0 bar to 40 bar
0.20 % F.S.Laboratory PremisesActive
  • Liquid Pressure (gauge)/ Digital and analogue indicating devices
  • 0 bar to 1200 bar
0.20 % F.S.Laboratory PremisesActive
Dimensions
  • Vernier Caliper (Analog & Digital)
  • SOP-013 (As per BS EN ISO 13385-1: 2019 )
  • 0 – 300 mm
0.03 mmLaboratory PremisesActive
  • >300 – 600 mm
0.030 mmLaboratory PremisesActive
  • Height Gauge (Analog & Digital)
  • SOP-014 (As per JIS B 7517:2018)
  • 0 – 300 mm
0.027 mmLaboratory PremisesActive
  • >300 – 600 mm
0.030 mmLaboratory PremisesActive
  • External Micrometer (Analog & Digital)
  • SOP-015 (As per JIS B 7502:2016)
  • 0 – 25 mm
0.002 mmLaboratory PremisesActive
  • >25 – 100 mm
0.004 mmLaboratory PremisesActive
  • Dial Gauge & Digital Indicator (Plunger Type)
  • SOP-017 (As per JIS B 7503:2017)
  • 0 – 12.7 mm
0.0027 mmLaboratory PremisesActive
  • Lever Type Test Indicator (Analog & Digital)
  • SOP-018 (As per JIS B 7533:2015)
  • Up to ±1 mm
2.4 μmLaboratory PremisesActive
  • Micro Indicator (Analog & Digital)
  • SOP-019 (As per JIS B 7519:1994)
  • Up to ± 1 mm
2.4 μmLaboratory PremisesActive
  • Feeler Gauge
  • SOP-021 (As per JIS B 7524:2008)
  • Up to 1mm
0.004 mmLaboratory PremisesActive
  • LVDT
  • SOP-022 (In-house Method)
  • Up to 25 mm
0.002 mmLaboratory Premises & Client PremisesActive
  • Squares
  • SOP-023 (As per JIS B 7526:1995)
  • Up to 200 mm
0.009 mmLaboratory PremisesActive
  • Straight Edge
  • SOP-024 (As per JIS B 7514:1977)
  • Up to 300 mm
0.005 mmLaboratory PremisesActive
  • Metal Ruler
  • SOP-025 (As per JIS B 7516:2005)
  • Up to 600 mm
0.60 mmLaboratory PremisesActive
  • Coating Thickness Foils
  • SOP-026 (In-house Method)
  • Up to 1533 μm
3.0 μmLaboratory PremisesActive
  • Coating Thickness Gauge
  • SOP-027 (In-house Method)
  • Up to 1500 μm
8.0 μmLaboratory PremisesActive