Metromac Marine Automation FZE

Initial Accreditation Date:Dec 31 , 2007

Contacts Info

Address

Dubai, United Arab Emirates

PO box / Zip Code

13485

Email

qaqc@metromac.com; cal@metromac.com

Website

www.metromac.com

Main Field

Calibration Laboratories

Valid Since:Dec 31 , 2025

Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Balance & Mass Calibration
  • Weighing Scale
  • Metromac Calibration Procedure MQS 03 C 75 based on ASTM898:20.
  • Upto 600 g
1.4 mgCustomer PremisesActive
  • OIML Masses Class F1 and Lower
  • Using E2 class W.I. MQS 03 C89 based on OIML R 111:2004
  • 1 mg
0.01 mgMetromac PremisesActive
  • OIML Masses Class F2 and Lower
  • Using F1 & M1 class W.I. MQS 03 C89 based on OIML R 111:2004
  • 500 g
0.85 mgMetromac PremisesActive
Dimensional Calibration
  • Calipers Dial & Analogue & Digital
  • MQS 03 C 54 based on BS EN ISO 13385-12019 For determining error of indicated size Comparison with gauge blocks or calliper checker
  • Up to 300 mm
26 µmMetromac PremisesActive
  • Tape & Scale Calibrator
  • MQS 03 C 113 For determining error of indicated displacement, Comparison with reference measuring tape
  • Up to 1 m
0.4 mmMetromac Premises / Customer PremisesActive
  • Ruler (Engineer or machinst scale)
  • MQS 03 C 112 Measurement of line spacing using length measuring machine equipped with optical magnification unit.
0.82 mmMetromac PremisesActive
  • Measuring Tape
  • MQS 03 C 112 Measurement of line spacing using length measuring machine equipped with optical magnification unit. Stitching is carried out after length of 1 m.
  • Up to 50 m
(0.7 mm +0.12 x L) mm L : mMetromac PremisesActive
  • Dial gauges (Digital & Analogue)
  • "MQS 03 C 111 based on JIS B 7503 for Mechanicals and based on VDI/VDE/DGQ/DKD 2618 Part 11.4 for Digital dial gauges For determining error of indicated displacement, Comparison with dial gauge calibrator"
  • Up to 25 mm (Digital / 0.001 mm)
2.7 µmMetromac PremisesActive
  • Internal two point (bore) micrometer
  • MQS 03 C 110 For determining error of indicated size Comparison with gauge blocks and scale of the universal length measuring machine (ULM).
  • Up to 300 mm
10 µmMetromac PremisesActive
  • External Micrometer (Digital & Analogue)
  • MQS 03 C 109 based on BS EN ISO 3611-2023 For determining error of indicated size Comparison with reference gauge blocks
  • Up to 25 mm
3 µmMetromac PremisesActive
  • Dial Gauge
  • Metromac calibration procedure MQS 03 C 164 based on JIS B 7503 2017 For determining error of indicated size Comparison with scale of the universal length measuring machine (ULM).
  • up to 100 mm
6.4 µmMetromac PremisesActive
  • Thickness Gauge (Digital/Analogue)
  • Metromac calibration procedure MQS 03 C 197 For determining error of indicated size Comparison with calibrated gauge blocks
  • up to 12.7 mm
2.5 µmMetromac PremisesActive
  • Thread Plug Gauge
  • Metromac calibration procedure MQS 03 C 162 based on EURAMET Guide -EURAMET cg-10. For determining Simple Pitch Diameter using ULM (three wire method) with nominal pitch: 0.5 mm to 6 mm.
  • 3 mm - 100 mm
3.5 µmMetromac PremisesActive
  • Diamater Standards: Setting / Plain Plug Gauges
  • Metromac calibration Procedure MQS 03 C 176 based on EURAMET Calibration Guide No.6 (V 3.0) - without measuring form For determining diameter Comparison with ULM scale / gauge blocks
  • 0.8 mm to 200 mm
(1 + 0.010* D) µm, ( D: mm)Metromac PremisesActive
  • Diamater Standards: Setting / Plain Ring Gauge
  • Metromac calibration Procedure MQS 03 C 165 based on EURAMET Calibration Guide No.6 (V 3.0) - without measuring form For determining diamater Comparison with reference ring gauge using ULM
  • 14 mm to 150 mm
(1.7 + 0.04* D) µm, ( D: mm)Metromac PremisesActive
  • Parallel Thread Ring Gauge
  • Metromac calibration Procedure MQS 03 C 163 based on EURAMET Guide -EURAMET cg-10. For determining Simple Pitch Diameter using ULM (two sphere method) with nominal pitch: 1 mm to 6 mm.
  • 14 mm to 100 mm
(3.6 + 0.040* D) µm, ( D: mm)Metromac PremisesActive
Volume Calibration
  • Macro Pipette, Micro Pipette, Dispenser
  • MQS 03 C 70, For determining error by Gravimetric Method based on ISO 8655 and uncertainty based on Euramet cg 19.
  • 0.5 µl up to 50 µl
0.04 µlMetromac PremisesActive
  • Beaker
  • METROMAC CALIBRATION PROCEDURE MQS 03 C 121 based on ISO 4787:2021.
  • up to 1000 ml
0.32 mlMetromac premisesActive
  • Burette
  • up to 10 ml
0.031 mlMetromac premisesActive
  • Measuring Cylinder
  • up to 200 ml
0.4 mlMetromac premisesActive
  • One Mark Flask
  • Upto 1000 ml
0.21 mlMetromac premisesActive
Speed Calibration
  • Speed (Centrifuge / Variable Rotation Speed) eg. : Centrifuges, Mixers, Orbit & Plate shakers, MST Apparatus, Autoclaves
  • SOP - MQS 03 C - 97
  • 6.00 to 999.9 rpm
1.0 rpmMetromac Premises & Customer PremisesActive
  • Timer (Centrifuge / Variable Rotation Speed) eg. : Centrifuges, Mixers, Orbit & Plate shakers, MST Apparatus, Autoclaves
  • Up to 30 min
0.81 sMetromac Premises & Customer PremisesActive
  • Timer/Stop watch
  • Metromac calibration Procedure:MQS 03 C 144 Comparison with reference Stopwatch
  • upto 8 hr (Resolution : 1 s )
0.81 sMetromac Premises & Customer PremisesActive
  • TACHOMETER Non-Contact
  • SOP - MQS 03 C-123
  • 6.00 to 99.99 rpm
0.01 rpmMetromac PremisesActive
Electrical-Measuring
  • AC Voltage
  • MetroMac Calibration Procedure MQS 03 C 60 (U=Measured Voltage Value)
  • ( 1.0 mV to 32.999 mV ) 10 Hz to 45 Hz
0.48 x 10-3 U + 3.9 µVMetromac PremisesActive
  • DC Voltage
  • MetroMac Calibration Procedure / MQS 03 C 60 (U=Measured Voltage Value)
  • 3 mV to 329.9999 mV
11 x 10-6 U + 1.4 µVMetromac PremisesActive
  • Resistance
  • MetroMac Calibration Procedure MQS 03 C 60 (R=Measured Resistance Value)
  • 0 Ω to 10.9999 Ω
22 x 10-6 R + 5.4 mΩMetromac PremisesActive
  • DC Current
  • MetroMac Calibration Procedure / MQS 03 C 60 (I=Measured Current Value)
  • 3 µA to 329.999 µA
82 x 10-6 I + 11 nAMetromac PremisesActive
  • AC Current
  • MetroMac Calibration Procedure MQS03 C60 (I=Measured Current Value)
  • (29.00 µA to 329.99 µA) >1 kHz to 5 kHz
1.6 x 10-3 I + 82 nAMetromac PremisesActive
  • Capacitance
  • MetroMac Calibration Procedure MQS 03 C 60 (C=Measured Capacitance Value)
  • (150 A to 1025 A) 0.19 to 0.3999 nF
3.1 x 10-3 C + 5.5 pFMetromac PremisesActive
  • Frequency
  • MetroMac Calibration Procedure MQS 03 C 60 (f=Measured Frequency Value)
  • 0.01 to 119.99 Hz
0.87 x 10-6 f + 0.08 mHzMetromac PremisesActive
  • RTD
  • MetroMac Calibration Procedure MQS 03 C 60
  • -200°C to 0 °C
0.055 °CMetromac PremisesActive
  • Thermocouple
  • (J-Type) -210 °C to -100 °C
0.25 °CMetromac PremisesActive
Electrical-Source
  • AC Voltage
  • MetroMac Calibration Procedur MQS 03 C 124 (U= Source Voltage Value)
  • (10 mV to 100 mV ) >10 Hz to 20 kHz
0.34 x 10-3 U + 22 µVMetromac PremisesActive
  • DC Voltage
  • MetroMac Calibration Procedure MQS 03 C 124 (U= Source Voltage Value)
  • (>100 V to 1000 V) 0 mV to 100 mV
20 x 10-6 U + 2.2 µVMetromac PremisesActive
  • Resistance
  • MetroMac Calibration Procedure MQS 03 C 124 (R= Source Resistance Value)
  • 0 Ω to 10 Ω
56 x 10-6 R + 1.6 mΩMetromac PremisesActive
  • DC Current
  • MetroMac Calibration Procedure MQS 03 C 124 (I= Source Current Value)
  • 10 µA to 100 µA
0.28 x 10-3 I + 14 nAMetromac PremisesActive
  • AC Current
  • MetroMac Calibration Procedure MQS 03 C 124 (I = Source Current Value)
  • (Upto 100 µA) 10 Hz to 5 kHz
0.55 x 10-3 I + 26 nAMetromac PremisesActive
  • Capacitance
  • MetroMac Calibration Procedure MQS 03 C 124 (C= Source Capacitance Value)
  • 0 nF to 1 nF
15 x 10-3 C + 14 pFMetromac PremisesActive
  • Frequency
  • MetroMac Calibration Procedure MQS 03 C 124 (f =Source Frequency Value)
  • 5 Hz to10 Hz
0.26 x 10-3 f + 0.21 mHzMetromac PremisesActive
  • RTD Source Pt 100 (-200 to 600)°C
  • MetroMac Calibration Procedure MQS 03 C 124
  • -200 °C to 0 °C
0.10 °CMetromac PremisesActive
  • Thermocouple - Simulation method
  • (J type) -210 °C to -100 °C
0.24 °CMetromac PremisesActive
Electrical
  • Resistance
  • MetroMac Calibration Procedure MQS 03 C 73
  • 10 MΩ to 10 GΩ
0.65 % rdgMetromac PremisesActive
  • Voltage
  • 50 V to 1 kV
0.1 % rdgMetromac PremisesActive
  • Continuity Resistance
  • MetroMac Calibration Procedure MQS 03 C 74
  • 100 mΩ to 10 kΩ
1.2 % rdgMetromac PremisesActive
  • Insulation- Resistance
  • 50 kΩ to 2 GΩ
1.2 % rdgMetromac PremisesActive
  • Insulation- Voltage
  • 50 V to 1000 V
1.2 % rdgMetromac PremisesActive
  • RCD Current
  • 6 m A to 30 m A
0.62 % rdgMetromac PremisesActive
  • RCD Trip Time
  • 10 ms to 2000 ms
0.59 msMetromac PremisesActive
  • Loop Impedance
  • Upto 0.300Ω
0.84 % rdg + 36mΩMetromac PremisesActive
Temperaure Calibration
  • Air temperature & Relative Humidity Sensors
  • METROMAC calibration procedure MQS 03 C 122
  • -10 °C to 50 °C
0.6 °CMetromac PremisesActive
  • Liquid in Glass Thermometer
  • METROMAC calibration procedure MQS 03 C 55
  • ­ 40 °C up to 130 °C
0.05 °CMetromac PremisesActive
  • Digital Thermometer
  • METROMAC calibration procedure MQS 03 C 59
0.05 °CMetromac PremisesActive
  • Infrared Thermometer
  • METROMAC calibration procedure MQS 03 C 107
  • -30 °C to -15°C
1.6 °CMetromac PremisesActive
  • Temperature Dry Block Calibrator
  • METROMAC calibration procedure MQS 03 C 24
  • ­ 30 °C up to 133 °C
0.20 °CMetromac PremisesActive
  • Liquid Bath (5 points)
  • METROMAC calibration procedure MQS 03 C 76 (5 points)
  • ­ 30 °C up up to 130 °C
0.60 °CCustomer PremisesActive
  • Incubator (5 points)
  • METROMAC calibration procedure MQS 03 C 65
  • 20 °C up to 100 °C
0.45 °CCustomer PremisesActive
  • Refrigerators/ Freezers (9 points)
  • METROMAC calibration procedure MQS 03 C 77
  • -80 °C to -30 °C
0.55 °CCustomer PremisesActive
  • Ovens (9 points)
  • METROMAC calibration procedure MQS 03 C 40 (9 points)
  • 25 °C up to 100 °C
0.75 °CCustomer PremisesActive
  • Muffle Furnace (1 point)
  • METROMAC calibration procedure MQS 03 C 90
  • 500 °C up to 900 °C
3.0 °CCustomer PremisesActive
  • Autoclaves
  • METROMAC calibration procedure MQS 03 C 96
  • up to 150°C
0.8 °CCustomer PremisesActive
Pressure Calibration
  • Pneumatic Pressure (Gauge) Analog and digital indicating and electrical output devices
  • Comparison with pressure transducer using W.I. MQS 03 C 61 & MQS 03 C 117 Based on: DKD R 6-1 : 2014 & cg17: 2017.
  • ­ 90 kPa up to 0 kPa
5 Pa + 0.02 % of readingMetromac Premises and Customer PremisesActive
  • Hydraulic Pressure (Gauge) Analog and digital indicating and electrical output devices
  • Comparison with DWT using W.I:MQS 03 C 56 & MQS 03 C 117 Based on DKD R 6 - 1: 2014 & cg 17: 2017
  • 0.6 MPa up to 6 Mpa
0.025 % of readingMetromac PremisesActive
Torque Calibration
  • Hand Torque Tools
  • Direct comparison with reference torque transducer using Work Instruction METROMAC calibration procedure MQS 03 C 115 Based on: ISO 6789-1:2017 and ISO 6789-2:2017
  • 0.04 N•m to 2 N•m Torque Transducer No:124712
0.015Metromac PremisesActive