Directory Details

Voyage Marine Automation

Initial Accreditation Date:Feb 16 , 2017

Contacts Info

Address

Dubai, United Arab Emirates

PO box / Zip Code

P.O. Box 119218

Email

calibration@voyagemarine.ae

Website

https://voyagemarine.ae/

Main Field

Calibration Laboratories

Valid Since:Oct 08 , 2025

Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Balance & Scale
  • Top loading weighing scale
Active
Electrical
  • DC Voltage
  • VG_LMS_WI-C-016 Electrical Meters BS EN 60359 & IEC 60359
  • Upto 330 mV
18 μVLaboratoryActive
  • >0.33 V to 3.3 V
0.13 mVLaboratoryActive
  • >3.3 V to 33 V
1.4 mVLaboratoryActive
  • >33 V to 330 V
15 mVLaboratoryActive
  • >330 V to 1000 V
45 mVLaboratoryActive
  • AC Voltage
  • VG_LMS_WI-C-016 Electrical Meters BS EN 60359 & IEC 60359
  • 1 mV to 33 mV (45 Hz to 1 kHz)
55 μVLaboratoryActive
  • >33mV to 330 mV (45 Hz to 1 kHz)
0.15 mVLaboratoryActive
  • >0.33 V to 3.3 V (45 Hz to 1 kHz)
1.0 mVLaboratoryActive
  • >3.3 V to 33 V (45 Hz to 1 kHz)
10 mVLaboratoryActive
  • >33 V to 330 V (45 Hz to 1 kHz)
0.16 VLaboratoryActive
  • >330 V to 1000 V (45 Hz to 1 kHz)
0.48 VLaboratoryActive
  • DC Current
  • VG_LMS_WI-C-016 Electrical Meters BS EN 60359 & IEC 60359
  • Upto 330 µA
77 nALaboratoryActive
  • >0.33 mA to 3.3 mA
0.38 μALaboratoryActive
  • >3.3 mA to 33 mA
3.7 μALaboratoryActive
  • >33 mA to 330 mA
89 μALaboratoryActive
  • >0.33 A to 2.2 A
0.69 mALaboratoryActive
  • >2.2 A to 11 A
4.0 mALaboratoryActive
  • AC Current
  • VG_LMS_WI-C-016 Electrical Meters BS EN 60359 & IEC 60359
  • 29 µA to 330 µA (45 Hz to 1 kHz)
0.51 μALaboratoryActive
  • >0.33 mA to 3.3 mA (45 Hz to 1 kHz)
2.4 μALaboratoryActive
  • >3.3 mA to 33 mA (45 Hz to 1 kHz)
23 μALaboratoryActive
  • >33 mA to 330 mA (45 Hz to 1 kHz)
0.28 mALaboratoryActive
  • >0.33 A to 2.2 A (45 Hz to 1 kHz)
1.2 mALaboratoryActive
  • >2.2 A to 11 A (45 Hz to 500 Hz)
11 mALaboratoryActive
  • Resistance
  • VG_LMS_WI-C-016 Electrical Meters BS EN 60359 & IEC 60359
  • Up to 11 Ω
4.3 mΩLaboratoryActive
  • >11 Ω to 330 Ω
21 mΩLaboratoryActive
  • >0.330 kΩ to 3.3 kΩ
0.16 ΩLaboratoryActive
  • >3.3 kΩ to 33 kΩ
1.6 ΩLaboratoryActive
  • >33 kΩ to 330 kΩ
21 ΩLaboratoryActive
  • >0.33 MΩ to 3.30 MΩ
0.29 kΩLaboratoryActive
  • >3.3 MΩ to 33 MΩ
17 kΩLaboratoryActive
  • >33 MΩ to 110 MΩ
0.27 MΩLaboratoryActive
  • >110 MΩ to 330 MΩ
1.1 MΩLaboratoryActive
  • Frequency
  • VG_LMS_WI-C-016 Electrical Meters BS EN 60359 & IEC 60359
  • 0.01 Hz to 100 Hz
5.3 mHzLaboratoryActive
  • >0.100 kHz to 10 kHz
0.53 HzLaboratoryActive
  • >10 kHz to 100 kHz
5.2 HzLaboratoryActive