Directory Details

OMICRON TESTING & RESEARCH LABORATORY

Initial Accreditation Date:Jul 26 , 2023

Contacts Info

Address

Dubai, United Arab Emirates

PO box / Zip Code

8544

Email

info@omicrontestinglab.com

Website

www.omicrontestinglab.com

Main Field

Testing Laboratories

Valid Since:Jul 26 , 2023

Type of Activity Test Materials / Products Test Name Test Method Status
Air Quality Monitoring
  • Air Quality Monitoring
  • Ambient/Outdoor Air Quality
  • Total Suspended Particulate Matter (TSPM)
USEPA 40 CFR Part 50 Appendix BActive
  • Respirable Suspended Particulate Matter (PM10)
USEPA 40 CFR Part 50 Appendix JActive
  • Total Suspended Particulate Matter (TSP)
AS/NZS 3580.12.1Active
  • Particulate Matter (PM10)
AS/NZS 3580.12.1Active
  • Particulate Matter (PM2.5)
AS/NZS 3580.12.1Active
  • Nitrogen Dioxide (NO2)
AS 3580.5.1Active
  • Sulphur Dioxide (SO2)
AS 3580.4.1Active
  • Carbon monoxide (CO)
AS 3580.7.1Active
  • Ozone (O3)
AS 3580.6.1Active
  • Total Volatile Organic Carbon (TVOC)
AS 3580.11.1Active
  • Ammonia (NH3)
In-house validated method SOP-ENV-03Active
  • Hydrogen Sulphide (H2S)
In-house validated method SOP-ENV-03Active
  • Temperature (T)
EPA-454/R-99-005Active
  • Relative Humidity (RH)
EPA-454/R-99-005Active
  • Wind Speed (WS)
EPA-454/R-99-005Active
  • Wind Direction (WD)
EPA-454/R-99-005Active
  • Noise Level Measurement
ISO 1996-2Active
  • Indoor Air Quality
  • Particulate Matter (PM1, PM2.5, PM4, PM7, PM10 & TSP)
ISO 21501-4Active
  • Nitrogen Dioxide (NO₂)
In-house validated method SOP-ENV-06Active
  • Sulphur Dioxide (SO₂)
In-house validated method SOP-ENV-06Active
  • Carbon monoxide (CO)
In-house validated method SOP-ENV-06Active
  • Carbon Dioxide (CO₂)
In-house validated method SOP-ENV-06Active
  • Ozone (O₃)
In-house validated method SOP-ENV-06Active
  • Oxygen (O₂)
In-house validated method SOP-ENV-06Active
  • Total Volatile Organic Carbon (TVOC)
In-house validated method SOP-ENV-06Active
  • Ammonia (NH₃)
In-house validated method SOP-ENV-06Active
  • Formaldehyde (HCOH)
In-house validated method SOP-ENV-06Active
  • Hydrogen Sulphide (H₂S)
In-house validated method SOP-ENV-06Active
  • Temperature (T)
In-house validated method SOP-ENV-06Active
  • Relative Humidity (RH)
In-house validated method SOP-ENV-06Active
  • Noise Level Measurement
ISO 1996-2Active
  • Illumination Level
BS 667Active
  • Flue Gas Emission/Stack Emission Monitoring
  • Carbon monoxide (CO)
USEPA CTM 030/034Active
  • Nitric Oxide (NO)
USEPA CTM 030/034Active
  • Nitrogen Dioxide (NO2)
USEPA CTM 030/034Active
  • Oxides of Nitrogen (NOX)
USEPA CTM 030/034Active
  • Oxygen (O2 )
USEPA CTM 030/034Active
  • Carbon Dioxide (CO₂)
USEPA 3AActive
  • Sulphur Dioxide (SO₂)
USEPA 6CActive
  • Hydrogen Sulphide (H2S)
USEPA CTM 030/034Active
  • Total Volatile Organic Compound (TVOC)
USEPA 25BActive
  • Ambient Temperature
USEPA 2Active
  • Gas Temperature
USEPA 2Active
  • Stack Emission monitoring
  • Determination of Stack gas Velocity and volumetric flow rate
USEPA-1 & 2Active
  • Determination of Particulate matter Emission from stationary sources
USEPA-5 & 17Active
  • Stack Diameter
USEPA-1 & 2Active
  • Determination of stack gas Moisture
USEPA- 4Active
  • Industrial premises and other workplaces
  • Determination of heat stress at work place
OSHA Technical Manual 2017 Chapter 4Active
  • Personnel Air Sampling
  • Inhalable Dust
MDHS 14/3Active
  • Respirable Dust
MDHS 14/3Active
  • Personal Noise Exposure Level
  • Noise Exposure Level
ISO 9612Active