Geoscience Testing laboratory

Initial Accreditation Date:Aug 09 , 2022

معلومات الاتصال

العنوان

P.O. Box 61670, Plot No. 531-519, Dubai Industrial City, Dubai UAE, Dubai, United Arab Emirates

صندوق بريد / الرمز البريدي

61670

البريد الإلكتروني

info@gtl.ae allan@uaeprime.com

الموقع الإلكتروني

www.geoscience.ae

رقم الهاتف

+971 052 987 3537

رقم الجوال

+971 04 431 4570

المجال الرئيسي

Calibration Laboratories

ساري منذ:Oct 20 , 2025

Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Balance & Scale
  • Top loading weighing scale
Active
Mass and Balance
  • Mass/ Non-automatic weighing instruments
  • Use of Mass Standards SOP GTL–TI–71 based on Euramet cg-18-v4: 2015
  • 1 mg to 20 mg
0.084 mgCustomer PremisesActive
  • >20 mg to 20 g
0.050 mgCustomer PremisesActive
  • >20 g to 200g
1.7 mgCustomer PremisesActive
  • >200 g to 1 kg
0.13 gCustomer PremisesActive
  • >1 kg to 6 kg
0.17 gCustomer PremisesActive
  • >6 kg to 30 kg
1.5 gCustomer PremisesActive
  • >30 kg to 150 kg
0.13 kgCustomer PremisesActive
Mass and weight
  • Mass/ Weights
  • Use of Mass Standards SOP GTL–TI–72 based on OIML R 111-1:2004
  • 1 mg
0.02 mgLaboratoryActive
  • 2 mg
0.02 mgLaboratoryActive
  • 5 mg
0.02 mgLaboratoryActive
  • 10 mg
0.02 mgLaboratoryActive
  • 20 mg
0.026 mgLaboratoryActive
  • 50 mg
0.02 mgLaboratoryActive
  • 100 mg
0.02 mgLaboratoryActive
  • 200 mg
0.048mgLaboratoryActive
  • 500 mg
0.071 mgLaboratoryActive
  • 1 g
0.03 mgLaboratoryActive
  • 2 g
0.04 mgLaboratoryActive
  • 5 g
0.05 mgLaboratoryActive
  • 10 g
0.06 mgLaboratoryActive
  • 20 g
0.08 mgLaboratoryActive
  • 50 g
0.17 mgLaboratoryActive
  • 100 g
0.2 mgLaboratoryActive
  • 200 g
0.36 mgLaboratoryActive
  • 500 g
82mgLaboratoryActive
  • 1 kg
82mgLaboratoryActive
  • 2 kg
82mgLaboratoryActive
  • 5 kg
82mgLaboratoryActive
  • 10 kg
82mgLaboratoryActive
  • 20 kg
300 mgLaboratoryActive
Temperature
  • Climatic Chambers Chiller/Freezers (9 Point Calibration)
  • GTL–TI–73 as per DKD R 5-7
  • -30°C up to 10 °C
0.90 °CCustomer PremisesActive
  • Climatic Chambers Incubators (9 Point Calibration)
  • 10°C up to 60 °C
0.87 °CCustomer PremisesActive
  • Climatic Chambers Ovens (9 Point Calibration)
  • 40°C up to 300 °C
1.2 °CCustomer PremisesActive
  • Liquid baths (5 point Calibration)
  • GTL–TI–73
  • 15 °C up to 100 °C
0.83 °CCustomer PremisesActive
  • Muffle furnaces (1 sensors)
  • GTL–TI–74 based on DKD R 5-7
  • 300 °C up to 1100 °C
6.7 °CCustomer PremisesActive
Dimensions
  • External Micrometer
  • GTL–TI–68 based on ISO 3611 For determining error of indicated size Comparison with reference gauge blocks
  • 0 mm to 25 mm
5 µmLaboratoryActive
  • All types of Caliper Digital / Dial / Vernier
  • GTL–TI–69 based on ISO 13385-1 For determining error of indicated size Comparison with calliper checker or gauge blocks
  • 0 mm to 300 mm
30 µmLaboratoryActive
  • 300 mm up to 600 mm
40 µmLaboratoryActive
  • Dial gauge
  • GTL–TI–70 based on ISO 463 / JIS B7503 For determining error of indicated size Comparison with dial gauge calibrator
  • 0 mm to 25 mm
7 µmLaboratoryActive
  • Comparison with gauge blocks
  • 0 mm to 100 mm
8 µmLaboratoryActive
  • Bore Gauge
  • GTL–TI–70 based on JIS 7515 For determining error of indicated size Comparison with dial gauge calibrator using special accessories
  • 0 mm to 400 mm
8 µmLaboratoryActive