AAB WEIGHING AND MEASURING LABORATORY LLC

Initial Accreditation Date:Jul 04 , 2021

معلومات الاتصال

العنوان

Dubai, United Arab Emirates

صندوق بريد / الرمز البريدي

1284

البريد الإلكتروني

calibration@aabtools.com

الموقع الإلكتروني

https://www.aabtools.com/

المجال الرئيسي

Calibration Laboratories

ساري منذ:Jul 25 , 2024

Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Balance & Scale
  • Top loading weighing scale
Active
Temperature
  • Liquid in Glass Thermometers
  • Comparison method using standard PRT with indicator. Calibration Procedure AAB-CP-T01
  • -30 °C to 125 °C
0.15 °CLaboratoryActive
  • Direct Reading Thermometers, Digital Thermometers, Temperature Indicators / Data Loggers with Sensor, Transmitters, Chart recorders
  • Comparison method using standard PRT with indicator. Calibration Procedure AAB-CP-T02
  • -30 °C to 650 °C
0.15 °CLaboratory/ Customer PremisesActive
  • Dry Block Calibrators
  • Comparison method using standard PRT with indicator. Calibration Procedure AAB-CP-T04
  • -30 °C to 300 °C
0.20 °CLaboratory/ Customer PremisesActive
  • >300 °C to 400 °C
0.40 °CLaboratory/ Customer PremisesActive
  • >400 °C to 650 °C
3.0 °CLaboratory/ Customer PremisesActive
  • Platinum Resistance Thermometers
  • Comparison method using standard PRT with indicator. Calibration Procedure AAB-CP-T08
  • -30 °C to 0 °C
0.20 °CLaboratory/ Customer PremisesActive
  • >0 °C to 200 °C
0.35 °CLaboratory/ Customer PremisesActive
  • >200 °C to 400 °C
0.55 °CLaboratory/ Customer PremisesActive
  • >400 °C to 650 °C
0.90 °CLaboratory/ Customer PremisesActive
  • Base metal thermocouples
  • -30 °C to 0 °C
0.20 °CLaboratory/ Customer PremisesActive
  • >0 °C to 200 °C
0.35 °CLaboratory/ Customer PremisesActive
  • >200 °C to 400 °C
0.55 °CLaboratory/ Customer PremisesActive
  • >400 °C to 650 °C
0.90 °CLaboratory/ Customer PremisesActive
  • Liquid baths
  • Comparison method at multipoints by using RTD sensor with indicator. Calibration Procedure AAB-CP-T03
  • -30 °C to 250 °C
0.40 °CLaboratory/ Customer PremisesActive
  • Dry Block Calibrators
  • Comparison method using standard Thermocouple Type K with indicator. Calibration Procedure AAB-CP-T04
  • >650 °C to 1200 °C
9.5 °CLaboratory/ Customer PremisesActive
  • Infrared Thermometers, Thermal Imagers
  • Comparison method using Standard IR Calibrator. Calibration Procedure AAB-CP-T07
  • -15 °C to 120 °C
1.2 °CLaboratoryActive
  • >120 °C to 350 °C
2.7 °CLaboratoryActive
  • >350 °C to 500 °C
3.8 °CLaboratoryActive
  • Chiller, Freezer, Refrigerator, Incubator, Climate Chamber
  • Comparison Method using Standard Multi Thermocouples with Multichannel Indicators at multi locations AAB-CP-T06 DKD-R 5-7 Method A or B
  • -30 °C to 100 °C
0.40 °CCustomer PremisesActive
  • Comparison Method at single location using Standard Thermocouples with Indicator AAB-CP-T05 DKD-R 5-7 Method C
0.40 °CCustomer PremisesActive
  • Oven, Autoclave, Hot Cabinet, Warmer, Hot Box
  • Comparison Method using Standard Multi Thermocouples with Multichannel Indicators at multi locations AAB-CP-T06 DKD-R 5-7 Method A or B
  • 25 °C to 400 °C
0.40 °CCustomer PremisesActive
  • Oven, Autoclave, Hot Cabinet, Warmer, Hot Box, Furnaces
  • Comparison Method at single location using Standard Thermocouples with Indicator AAB-CP-T05 DKD-R 5-7 Method C
0.40 °CCustomer PremisesActive
  • Measuring position in Furnace
  • >400 °C to 600 °C
4.0 °CLaboratory/ Customer PremisesActive
  • >600 °C to 1200 °C
6.0 °CLaboratory/ Customer PremisesActive
  • Dish washers,Glass Washer
  • 20 °C to 90 °C
0.70 °CCustomer PremisesActive
  • Thermo-Hygrometers, Relative Humidity Digital/Analog Meters, Relative Humidity Sensors With Indicator/Transmitters, Relative Humidity Data Loggers
  • Comparison method at (0 to 50°C) using Standard Thermohygrometer in Chamber. Calibration Procedure AAB-CP-T09
  • 20 %RH to 90 %RH
2.0 %RHLaboratoryActive
  • Humidity Chamber
  • Comparison method at a single location using standard ThermoHygrometer. Calibration Procedure AAB-CP-T05 based on DKD R 5-7 Method C.
  • 35 %RH to 50 %RH (For Temperature 23 °C ±2 °C)
2.6 %RHLaboratory/ Customer PremisesActive
  • >50 %RH to 80 %RH (For Temperature 23 °C ±2 °C)
3.0 %RHLaboratory/ Customer PremisesActive
Balance
  • Weighing Balance
  • AAB-CP-W01 based on Euramet cg 18
  • 0 to 110 g
3.0 mgCustomer PremisesActive
  • > 110 g to 320 g
7.0 mgCustomer PremisesActive
  • > 320 g to 610 g
30 mgCustomer PremisesActive
  • > 610 g to 2100 g
45 mgCustomer PremisesActive
  • > 2.1 kg to 8 kg
0.15 mgCustomer PremisesActive
  • > 8 kg to 15 kg
0.30 gCustomer PremisesActive
  • > 15 kg to 35 kg
0.70 gCustomer PremisesActive
  • > 35 kg to 50 kg
160 gCustomer PremisesActive
  • > 50 kg to 250 kg
0.27 kgCustomer PremisesActive
  • > 250 kg to 500kg
0.46 kgCustomer PremisesActive
  • > 500 kg to 750 kg
0.67 kgCustomer PremisesActive
  • > 750 kg to 1000 kg
0.88 kgCustomer PremisesActive
Pressure
  • Pneumatic Pressure Gauge
  • Comparison method according to DKD-R 6-1:Edition 03/2014
  • -92 kPa to 0
3 kPaLaboratory/ Customer PremisesActive
  • 0 to 10 MPa
3 kPaLaboratory/ Customer PremisesActive
  • Pneumatic Pressure Absolute
  • 305 hPa to 1100 hPa
0.80 hPaLaboratoryActive
  • Hydraulic Pressure Gauge
  • 0 to 70 MPa
7 kPaLaboratory/ Customer PremisesActive
Electrical
  • Electrical Source Mode (DC Voltage)
  • Calibration Procedure # AAB-CP-E01 Using Fluke 5522A (U = Measured Voltage Value)
  • Up to 330mV
29 x10¯⁶.U + 1.0 μVLaboratory/ Customer PremisesActive
  • > 0.33 V to 3.3 V
15 x10¯⁶.U + 2.0 μVLaboratory/ Customer PremisesActive
  • > 3.3 V to 33 V
16 x10¯⁶.U + 20 μVLaboratory/ Customer PremisesActive
  • > 33 V to 330 V
23 x10¯⁶.U + 0.2 mVLaboratory/ Customer PremisesActive
  • > 330 V to 1000V
24 x10¯⁶.U + 1.5 mVLaboratory/ Customer PremisesActive
  • Electrical Source Mode (AC Voltage)
  • (Up to 32.999 mV ) 10 Hz to 45 Hz
0.90 x10¯³.U + 8.0 μVLaboratory/ Customer PremisesActive
  • (Up to 32.999 mV ) >45 Hz to 20 kHz
0.60 x10¯³.U + 8.0 μVLaboratory/ Customer PremisesActive
  • (Up to 32.999 mV ) >20 kHz to 50 kHz
0.80 x10¯³.U + 8.0 μVLaboratory/ Customer PremisesActive
  • (Up to 32.999 mV ) >50 kHz to 100 kHz
2.2 x10¯³.U + 32 μVLaboratory/ Customer PremisesActive
  • (Up to 32.999 mV ) >100 kHz to 500 kHz
5.1 x10¯³.U + 70 μVLaboratory/ Customer PremisesActive
  • (33 mV to 329.999 mV) 10 Hz to 45 Hz
0.70 x10¯³.U + 50 μVLaboratory/ Customer PremisesActive
  • (33 mV to 329.999 mV) >45 Hz to 20 kHz
0.50 x10¯³.U + 60 μVLaboratory/ Customer PremisesActive
  • (33 mV to 329.999 mV) >20 kHz to 50 kHz
0.60 x10¯³.U + 50 μVLaboratory/ Customer PremisesActive
  • Calibration Procedure # AAB-CP-E01 Using Fluke 5522SA (U = Measured Voltage Value)
  • (33 mV to 329.999 mV) >50 kHz to 100 kHz
1.4 x10¯³.U + 0.13 mVLaboratory/ Customer PremisesActive
  • (33 mV to 329.999 mV) >100 kHz to 500 kHz
5.0 x10¯³.U + 6.0 mVLaboratory/ Customer PremisesActive
  • (0.33 V to 3.29999 V ) 10 Hz to 45 Hz
0.70 x10¯³.U + 0.65 mVLaboratory/ Customer PremisesActive
  • (0.33 V to 3.29999 V ) >45 Hz to 10 kHz
0.50 x10¯³.U + 0.60 mVLaboratory/ Customer PremisesActive
  • (0.33 V to 3.29999 V ) >10 kHz to 20 kHz
0.60 x10¯³.U + 0.60 mVLaboratory/ Customer PremisesActive
  • (0.33 V to 3.29999 V ) >20 kHz to 50 kHz
0.80 x10¯³.U + 0.60 mVLaboratory/ Customer PremisesActive
  • (0.33 V to 3.29999 V ) >50 kHz to 100 kHz
2.0 x10¯³.U + 1.6 mVLaboratory/ Customer PremisesActive
  • (0.33 V to 3.29999 V ) >100 kHz to 500 kHz
3.0 x10¯³.U + 2.0 mVLaboratory/ Customer PremisesActive
  • (3.3 V to 32.9999 V) 10 Hz to 45 Hz
0.40 x10¯³.U + 2.0 mVLaboratory/ Customer PremisesActive
  • (3.3 V to 32.9999 V) >45 Hz to 10 kHz
0.50 x10¯³.U + 6.0 mVLaboratory/ Customer PremisesActive
  • (3.3 V to 32.9999 V) >10 kHz to 50 kHz
0.60 x10¯³.U + 6.0 mVLaboratory/ Customer PremisesActive
  • (3.3 V to 32.9999 V) >50 kHz to 100 kHz
4.3 x10¯³.U + 50 mVLaboratory/ Customer PremisesActive
  • Calibration Procedure # AAB-CP-E01 Using Fluke 5522A (U = Measured Voltage Value)
  • (33 V to 329.999 V ) 45 Hz to 10 kHz
0.50 x10¯³.U + 10 mVLaboratory/ Customer PremisesActive
  • (33 V to 329.999 V ) >10 kHz to 100 kHz
0.70 x10¯³.U + 14 mVLaboratory/ Customer PremisesActive
  • (330 V to 1020 V) 45 Hz to 10 kHz
0.40 x10¯³.U + 10 mVLaboratory/ Customer PremisesActive
  • Electrical Source Mode DC Current
  • Calibration Procedure # AAB-CP-E01 Using Fluke 5522A (U = Measured Voltage Value
  • 1μA to 329.999 μA
0.30 x10¯³./ + 20 nALaboratory/ Customer PremisesActive
  • 0.33 mA to 3.29999 mA
0.20 x10¯³.I + 50 nALaboratory/ Customer PremisesActive
  • 3.3 mA to 32.9999 mA
0.20 x10¯³.I + 0.25 μALaboratory/ Customer PremisesActive
  • 33 mA to 329.999 mA
0.40 x10¯³.I + 2.5 μALaboratory/ Customer PremisesActive
  • 0.33 A to 1.09999 A
0.50 x10¯³.I + 40 μALaboratory/ Customer PremisesActive
  • 1.1 A to 2.99999 A
0.50 x10¯³.I + 40 μALaboratory/ Customer PremisesActive
  • 3 A to 10.9999 A
0.70 x10¯³.I + 0.50 mALaboratory/ Customer PremisesActive
  • 11 A to 20.5 A
1.2x10¯³.I + 0.75 mALaboratory/ Customer PremisesActive
  • Calibration Procedure # AAB-CP-E01 and AAB-CP-E03 Using Fluke 5522A with X50 Turn Current Coil (I = Measured Current Value)
  • (X 50 Turn Coil) 10 A to 16.5 A
4.4 x10¯³.I + 0.14 ALaboratory/ Customer PremisesActive
  • (X 50 Turn Coil) >16.5 A to 150 A
2.3 x10¯³.I + 0.50 ALaboratory/ Customer PremisesActive
  • (X 50 Turn Coil) >150 A to 1025 A
3.5 x10¯³.I + 0.50 ALaboratory/ Customer PremisesActive
  • Electrical Source Mode AC Current
  • Calibration Procedure # AAB-CP-E01 Using Fluke 5522A (I = Measured Current Value)
  • (29.00 μA to 329.99 μA ) 10 Hz to 20 Hz
3.6 x10¯³.I + 0.10 μALaboratory/ Customer PremisesActive
  • (29.00 μA to 329.99 μA ) >20 Hz to 45 Hz
2.5 x10¯³.I + 0.10 μALaboratory/ Customer PremisesActive
  • (29.00 μA to 329.99 μA ) >45 Hz to 1 kHz
2.2 x10¯³.I + 0.10 μALaboratory/ Customer PremisesActive
  • (29.00 μA to 329.99 μA ) >1 kHz to 5 kHz
4.3 x10¯³.I + 0.15 μALaboratory/ Customer PremisesActive
  • (29.00 μA to 329.99 μA ) >5 kHz to 10 kHz
11 x10¯³.I + 0.20 μALaboratory/ Customer PremisesActive
  • (29.00 μA to 329.99 μA ) >10 kHz to 30 kHz
32 x10¯³.I + 0.40 μALaboratory/ Customer PremisesActive
  • (0.33 mA to 3.29999 mA) 10 Hz to 20 Hz
3.0 x10¯³.I + 0.15 μALaboratory/ Customer PremisesActive
  • (0.33 mA to 3.29999 mA) >20 Hz to 45 Hz
2.0 x10¯³.I + 0.15 μALaboratory/ Customer PremisesActive
  • (0.33 mA to 3.29999 mA) >45 Hz to 1 kHz
1.4 x10¯³.I + 0.15 μALaboratory/ Customer PremisesActive
  • (0.33 mA to 3.29999 mA) >1 kHz to 5 kHz
2.7 x10¯³.I + 0.20 μALaboratory/ Customer PremisesActive
  • (0.33 mA to 3.29999 mA) >5 kHz to 10 kHz
6.5 x10¯³.I + 0.30 μALaboratory/ Customer PremisesActive
  • (0.33 mA to 3.29999 mA) >10 kHz to 30 kHz
15 x10¯³.I + 0.60 μALaboratory/ Customer PremisesActive
  • Calibration Procedure # AAB-CP-E01 Using Fluke 5522A (I = Measured Current Value)
  • (3.3 mA to 32.9999 mA) 10 Hz to 20 Hz
2.2 x10¯³.I+ 2.0 μALaboratory/ Customer PremisesActive
  • (3.3 mA to 32.9999 mA) >20 Hz to 45 Hz
1.1 x10¯³.I+ 2.0 μALaboratory/ Customer PremisesActive
  • (3.3 mA to 32.9999 mA) >45 Hz to 1 kHz
0.60 x10¯³.I+ 2.0 μALaboratory/ Customer PremisesActive
  • (3.3 mA to 32.9999 mA) >1 kHz to 5 kHz
1.0 x10¯³.I+ 2.0 μALaboratory/ Customer PremisesActive
  • (3.3 mA to 32.9999 mA) >5 kHz to 10 kHz
2.4 x10¯³.I+ 3.0 μALaboratory/ Customer PremisesActive
  • (3.3 mA to 32.9999 mA) >10 kHz to 30 kHz
4.8 x10¯³.I+ 4.0 μALaboratory/ Customer PremisesActive
  • (33 mA to 329.999 mA ) >10 Hz to 20 Hz
2.7 x10¯³.I + 20 μALaboratory/ Customer PremisesActive
  • (33 mA to 329.999 mA ) >20 Hz to 45 Hz
1.5 x10¯³.I + 20 μALaboratory/ Customer PremisesActive
  • (33 mA to 329.999 mA ) >45 Hz to 1 kHz
1.1 x10¯³.I + 20 μALaboratory/ Customer PremisesActive
  • (33 mA to 329.999 mA ) >1 kHz to 5 kHz
1.8 x10¯³.I + 50 μALaboratory/ Customer PremisesActive
  • (33 mA to 329.999 mA ) >5 kHz to 10 kHz
3.7 x10¯³.I + 0.10 mALaboratory/ Customer PremisesActive
  • (33 mA to 329.999 mA ) >10 kHz to 30 kHz
6.0 x10¯³.I + 0.20 mALaboratory/ Customer PremisesActive
  • (0.33 A to 1.09999 A ) 10 Hz to 45 Hz
2.3 x10¯³.I + 0.10 mALaboratory/ Customer PremisesActive
  • (0.33 A to 1.09999 A ) >45 Hz to 1 kHz
0.80 x10¯³.I + 0.10 mALaboratory/ Customer PremisesActive
  • Calibration Procedure # AAB-CP-E01 Using Fluke 5522A (I = Measured Current Value)
  • (0.33 A to 1.09999 A ) >1 kHz to 5 kHz
8.0 x10¯³.I + 1.0 mALaboratory/ Customer PremisesActive
  • (0.33 A to 1.09999 A ) >5 kHz to 10 kHz
35 x10¯³.I + 5.0 mALaboratory/ Customer PremisesActive
  • (1.1 A to 2.99999 A ) 10 Hz to 45 Hz
2.6 x10¯³.I + 0.10 mALaboratory/ Customer PremisesActive
  • (1.1 A to 2.99999 A ) >45 Hz to 1 kHz
1.6 x10¯³.I + 0.10 mALaboratory/ Customer PremisesActive
  • (1.1 A to 2.99999 A ) >1 kHz to 5 kHz
7.8 x10¯³.I + 1.0 mALaboratory/ Customer PremisesActive
  • (1.1 A to 2.99999 A ) >5 kHz to 10 kHz
31 x10¯³.I + 5.0 mALaboratory/ Customer PremisesActive
  • (3 A to 10.9999 A ) 45 Hz to 100 Hz
1.0 x10¯³.I + 2.0 mALaboratory/ Customer PremisesActive
  • (3 A to 10.9999 A ) >100 Hz to 1 kHz
1.5 x10¯³.I + 2.0 mALaboratory/ Customer PremisesActive
  • (3 A to 10.9999 A ) >1 kHz to 5 kHz
35 x10¯³.I + 2.0 mALaboratory/ Customer PremisesActive
  • (11 A to 20.5 A) 45 Hz to 100 Hz
2.0 x10¯³.I + 5.0 mALaboratory/ Customer PremisesActive
  • (11 A to 20.5 A) >100 Hz to 1 kHz
2.3 x10¯³.I + 5.0 mALaboratory/ Customer PremisesActive
  • (11 A to 20.5 A) >1 kHz to 5 kHz
35 x10¯³.I + 5.0 mALaboratory/ Customer PremisesActive
  • (10 A to 300 A) 45 Hz to 65 Hz
3.0 x10¯³.I + 0.90 ALaboratory/ Customer PremisesActive
  • (> 300 A to 600 A) 45 Hz to 65 Hz
3.6 x10¯³.I + 0.90 ALaboratory/ Customer PremisesActive
  • (> 600 A to 1000 A) 45 Hz to 65 Hz
3.5 x10¯³.I + 0.90 ALaboratory/ Customer PremisesActive
  • Electrical Source Mode Resistance
  • Calibration Procedure # AAB-CP-E01 Using Fluke 5522A and Fluke 5320A (R = Measured Resistance Value)
  • 100 mΩ to 200 mΩ
63 x10¯³.R + 10 mΩLaboratory/ Customer PremisesActive
  • >200 mΩ to 400 mΩ
34 x10¯³.R + 10 mΩLaboratory/ Customer PremisesActive
  • >400 mΩ to 1 Ω
19 x10¯³.R + 10 mΩLaboratory/ Customer PremisesActive
  • >1 Ω to 10.9999 Ω
0.20 x10¯³.R + 1.5 mΩLaboratory/ Customer PremisesActive
  • 11 Ω to 32.9999 Ω
94 x10¯⁶.R + 1.4 mΩLaboratory/ Customer PremisesActive
  • 33 Ω to 109.9999 Ω
58 x10¯⁶.R + 2.0 mΩLaboratory/ Customer PremisesActive
  • 110 Ω to 329.9999 Ω
47 x10¯⁶.R + 2.0 mΩLaboratory/ Customer PremisesActive
  • 330 Ω to 1.099999 kΩ
56 x10¯⁶.R + 20 mΩLaboratory/ Customer PremisesActive
  • 1.1 kΩ to 3.299999 kΩ
50 x10¯⁶.R + 20 mΩLaboratory/ Customer PremisesActive
  • 3.3 kΩ to 10.99999 kΩ
37 x10¯⁶.R + 20 mΩLaboratory/ Customer PremisesActive
  • 11 kΩ to 32.99999 kΩ
47 x10¯⁶.R + 0.20 ΩLaboratory/ Customer PremisesActive
  • 33 kΩ to 109.9999 kΩ
64 x10¯⁶.R + 2.0 ΩLaboratory/ Customer PremisesActive
  • 110 kΩ to 329.99999 kΩ
66 x10¯⁶.R + 2.0 ΩLaboratory/ Customer PremisesActive
  • 330 kΩ to 1.099999 MΩ
0.13 x10¯3.R + 30 ΩLaboratory/ Customer PremisesActive
  • 1.1 MΩ to 3.299999 MΩ
0.2 x10¯3.R + 50 ΩLaboratory/ Customer PremisesActive
  • 3.3 MΩ to 10.99999 MΩ
0.6 x10¯³.R + 2.5 kΩLaboratory/ Customer PremisesActive
  • 11 MΩ to 32.99999 MΩ
0.9 x10¯³.R + 3.0 kΩLaboratory/ Customer PremisesActive
  • 33 MΩ to 109.9999 MΩ
4.5 x10¯³.R + 0.10 MΩLaboratory/ Customer PremisesActive
  • 110 MΩ to 329.9999 MΩ
20 x10¯³.R + 0.50 MΩLaboratory/ Customer PremisesActive
  • 330 MΩ to 1100 MΩ
18 x10¯³.R + 0.50 MΩLaboratory/ Customer PremisesActive
  • Electrical Source Mode Capacitance
  • Calibration Procedure # AAB-CP-E01 Using Fluke 5522A (C = Measured Capacitance Value)
  • 220 pF to 399.9 pF
35 x10¯³.C + 10 pFLaboratory/ Customer PremisesActive
  • 0.4 nF to 1.0999 nF
18 x10¯³.C + 10 pFLaboratory/ Customer PremisesActive
  • 1.1 nF to 3.2999 nF
6.8 x10¯³.C + 10 pFLaboratory/ Customer PremisesActive
  • 3.3 nF to 10.9999 nF
6.7 x10¯³.C + 10 pFLaboratory/ Customer PremisesActive
  • 11 nF to 32.9999 nF
3.6 x10¯³.C + 10 pFLaboratory/ Customer PremisesActive
  • 33 nF to 109.999 nF
3.3 x10¯³.C + 30 pFLaboratory/ Customer PremisesActive
  • 110 nF to 329.999 nF
19 x10¯³.C + 1.0 nFLaboratory/ Customer PremisesActive
  • 0.33 μF to 1.09999 μF
8.1 x10¯³.C + 3.0 nFLaboratory/ Customer PremisesActive
  • 1.1 μF to 3.29999 μF
19 x10¯³.C + 10 nFLaboratory/ Customer PremisesActive
  • 3.3 μF to 10.9999 μF
9.6 x10¯³.C + 30 nFLaboratory/ Customer PremisesActive
  • 11 μF to 32.9999 μF
10 x10¯³.C + 0.10 µFLaboratory/ Customer PremisesActive
  • 33 μF to 109.999 μF
9.0 x10¯³.C + 0.30 μFLaboratory/ Customer PremisesActive
  • 110 μF to 329.999 μF
20 x10¯³.C + 1.0 μFLaboratory/ Customer PremisesActive
  • 0.33 mF to 1.09999 mF
10 x10¯³.C + 3.0 μFLaboratory/ Customer PremisesActive
  • 1.1 mF to 3.29999 mF
20 x10¯³.C + 10 μFLaboratory/ Customer PremisesActive
  • 3.3 mF to 10.9999 mF
14 x10¯³.C + 30 μFLaboratory/ Customer PremisesActive
  • 11 mF to 32.9999 mF
17 x10¯³.C + 0.10 mFLaboratory/ Customer PremisesActive
  • 33 mF to 110 mF
14 x10¯³.C + 0.10 mFLaboratory/ Customer PremisesActive
  • Electrical Source Mode Frequency
  • Calibration Procedure # AAB-CP-E01 Using Fluke 5522A (F = Measured Frequency Value)
  • 0.01 Hz to 119.99 Hz
8.4 x10¯⁶.F + 5.0 µHzLaboratory/ Customer PremisesActive
  • 120.0 Hz to 1199.9 Hz
0.50 x10¯⁶.F + 5.0 µHzLaboratory/ Customer PremisesActive
  • 1.200 kHz to 11.999 kHz
50 x10¯⁶.F + 5.0 mHzLaboratory/ Customer PremisesActive
  • 12.00 kHz to 119.99 kHz
5.7 x10¯⁶.F + 5.0 mHzLaboratory/ Customer PremisesActive
  • 120.0 kHz to 1199.9 kHz
0.50 x10¯⁶.F + 5.0 HzLaboratory/ Customer PremisesActive
  • Electrical Source Mode Insulation Resistance Voltage (50 V to 10 kV)
  • 1.200 MHz to 2.000 MHz
0.30 x10¯3.F + 5.0 HzLaboratory/ Customer PremisesActive
  • Calibration Procedure # AAB-CP-E05 Using Fluke 5522A and Fluke 5320 A (IR = Measured Insulation Resistance Value)
  • 10 kΩ to 999.9 kΩ
2.4 x10¯³.IR + 2.0 kΩLaboratory/ Customer PremisesActive
  • 1 MΩ to 9.999 MΩ
3.8 x10¯³.IR + 30 kΩLaboratory/ Customer PremisesActive
  • 10 MΩ to 999.99 MΩ
7.6 x10¯³.IR + 5.0 MΩLaboratory/ Customer PremisesActive
  • 1 GΩ to 9.9 GΩ
14 x10¯³.IR + 0.10 GΩLaboratory/ Customer PremisesActive
  • 10 GΩ to 99.9 GΩ
35 x10¯³.IR + 3.0 GΩLaboratory/ Customer PremisesActive
  • 100 GΩ to 999.9 GΩ
24 x10¯³.IR + 20 GΩLaboratory/ Customer PremisesActive
  • 1 TΩ to 10 TΩ
39 x10¯³.IR + 0.30 TΩLaboratory/ Customer PremisesActive
  • Electrical Source Mode DC Power
  • Calibration Procedure # AAB-CP-E04 Using Fluke 5522A (P = Measured Power Value)
  • (0.011 mW to 20.91 kW )(Voltage: (33 mV to 1020 V)) 0.33 mA to 329.999 mA
0.80 x10¯³.PLaboratory/ Customer PremisesActive
  • (0.011 mW to 20.91 kW )(Voltage: (33 mV to 1020 V)) 0.33 A to 3 A
0.50 x10¯³.PLaboratory/ Customer PremisesActive
  • (0.011 mW to 20.91 kW )(Voltage: (33 mV to 1020 V)) 3 A to 20.5 A
1.1 x10¯³.PLaboratory/ Customer PremisesActive
  • Electrical Source Mode AC Power
  • (45 Hz to 65 Hz, PF=1)(Voltage (33 mV to 329.999 mV)) (0.11 mW to 20.91 kW) 0.33 mA to 8.9999 mA
2.3 x10¯³.PLaboratory/ Customer PremisesActive
  • (45 Hz to 65 Hz, PF=1)(Voltage (33 mV to 329.999 mV)) (0.11 mW to 20.91 kW) 9 mA to 32.999 mA
1.7 x10¯³.PLaboratory/ Customer PremisesActive
  • (45 Hz to 65 Hz, PF=1)(Voltage (33 mV to 329.999 mV)) (0.11 mW to 20.91 kW) 33 mA to 89.999 mA
1.3 x10¯³.PLaboratory/ Customer PremisesActive
  • (45 Hz to 65 Hz, PF=1)(Voltage (33 mV to 329.999 mV)) (0.11 mW to 20.91 kW) 90 mA to 329.999 mA
1.5 x10¯³.PLaboratory/ Customer PremisesActive
  • (45 Hz to 65 Hz, PF=1)(Voltage (33 mV to 329.999 mV)) (0.11 mW to 20.91 kW) 0.33 A to 0.8999 A
1.5 x10¯³.PLaboratory/ Customer PremisesActive
  • (45 Hz to 65 Hz, PF=1)(Voltage (33 mV to 329.999 mV)) (0.11 mW to 20.91 kW) 0.9 A to 2.1999 A
1.7 x10¯³.PLaboratory/ Customer PremisesActive
  • (45 Hz to 65 Hz, PF=1)(Voltage (33 mV to 329.999 mV)) (0.11 mW to 20.91 kW) 2.2 A to 4.4999 A
4.2 x10¯³.PLaboratory/ Customer PremisesActive
  • (45 Hz to 65 Hz, PF=1)(Voltage (33 mV to 329.999 mV)) (0.11 mW to 20.91 kW) 4.5 A to 20.5 A
1.5 x10¯³.PLaboratory/ Customer PremisesActive
  • (45 Hz to 65 Hz, PF=1)(Voltage (330 mV to 1020 V)) (0.11 mW to 20.91 kW) 0.33 mA to 8.9999 mA
1.5 x10¯³.PLaboratory/ Customer PremisesActive
  • (45 Hz to 65 Hz, PF=1)(Voltage (330 mV to 1020 V)) (0.11 mW to 20.91 kW) 9 mA to 32.999 mA
1.5 x10¯³.PLaboratory/ Customer PremisesActive
  • (45 Hz to 65 Hz, PF=1)(Voltage (330 mV to 1020 V)) (0.11 mW to 20.91 kW) 33 mA to 89.999 mA
1.0 x10¯³.PLaboratory/ Customer PremisesActive
  • (45 Hz to 65 Hz, PF=1)(Voltage (330 mV to 1020 V)) (0.11 mW to 20.91 kW) 90 mA to 329.999 mA
1.5 x10¯³.PLaboratory/ Customer PremisesActive
  • (45 Hz to 65 Hz, PF=1)(Voltage (330 mV to 1020 V)) (0.11 mW to 20.91 kW) 0.33 A to 0.8999 A
1.3 x10¯³.PLaboratory/ Customer PremisesActive
  • (45 Hz to 65 Hz, PF=1)(Voltage (330 mV to 1020 V)) (0.11 mW to 20.91 kW) 0.9 A to 2.1999 A
1.6 x10¯³.PLaboratory/ Customer PremisesActive
  • (45 Hz to 65 Hz, PF=1)(Voltage (330 mV to 1020 V)) (0.11 mW to 20.91 kW) 2.2 A to 4.4999 A
1.4 x10¯³.PLaboratory/ Customer PremisesActive
  • (45 Hz to 65 Hz, PF=1)(Voltage (330 mV to 1020 V)) (0.11 mW to 20.91 kW) 4.5 A to 20.5 A
1.4 x10¯³.PLaboratory/ Customer PremisesActive
  • Calibration Procedure # AAB-CP-E04 and AAB-CP-E03 Using Fluke 5522A (P = Measured Power Value)
  • (Voltage (100 V to 1000 V)) (45 Hz to 65 Hz, PF=1) (100 W to 750 kW) 1 A to 50 A
1.3 x10¯³.PLaboratory/ Customer PremisesActive
  • (Voltage (100 V to 1000 V)) (45 Hz to 65 Hz, PF=1) (100 W to 750 kW) >50 A to 250 A
1.4 x10¯³.PLaboratory/ Customer PremisesActive
  • (Voltage (100 V to 1000 V)) (45 Hz to 65 Hz, PF=1) (100 W to 750 kW) >250 A to 500 A
1.4 x10¯³.PLaboratory/ Customer PremisesActive
  • (Voltage (100 V to 1000 V)) (45 Hz to 65 Hz, PF=1) (100 W to 750 kW) >500 A to 750 A
1.4 x10¯³.PLaboratory/ Customer PremisesActive
  • Electrical Measure Mode DC Voltage
  • Calibration Procedure # AAB-CP-E02 Using Fluke 8846A (U = Measured Voltage Value)
  • 1 mV to 100 mV
87 x10¯⁶.U + 3.5 μVLaboratory/ Customer PremisesActive
  • >0.1 V to 1 V
38 x10¯⁶.U + 0.70 mVLaboratory/ Customer PremisesActive
  • >1 V to 10 V
35 x10¯⁶.U + 0.50 mVLaboratory/ Customer PremisesActive
  • >10 V to 100 V
51 x10¯⁶.U + 0.60 mVLaboratory/ Customer PremisesActive
  • >100 V to 1000 V
60 x10¯⁶.U + 1.0 mVLaboratory/ Customer PremisesActive
  • Electrical Measure Mode AC Voltage
  • (10 mV to 100 mV) 10 Hz to 20 kHz
1.2 x10¯³.U + 40 µVLaboratory/ Customer PremisesActive
  • (10 mV to 100 mV) >20 kHz to 50 kHz
2.0 x10¯³.U + 50 µVLaboratory/ Customer PremisesActive
  • (10 mV to 100 mV) >50 kHz to 100 kHz
7.9 x10¯³.U + 80 µVLaboratory/ Customer PremisesActive
  • (10 mV to 100 mV) >100 kHz to 300 kHz
52 x10¯³.U + 0.50 mVLaboratory/ Customer PremisesActive
  • (> 0.1 V to 1 V) v 10 Hz to 20 kHz
1.1 x10¯³.U + 0.30 mVLaboratory/ Customer PremisesActive
  • (> 0.1 V to 1 V) >20 kHz to 50 kHz
2.0 x10¯³.U + 0.50 mVLaboratory/ Customer PremisesActive
  • (> 0.1 V to 1 V) >50 kHz to 100 kHz
7.9 x10¯³.U + 0.80 mVLaboratory/ Customer PremisesActive
  • (> 0.1 V to 1 V) >100 kHz to 300 kHz
52 x10¯³.U + 5.0 mVLaboratory/ Customer PremisesActive
  • (> 1 V to 10 V) 10 Hz to 20 kHz
1.1 x10¯³.U + 3.0 mVLaboratory/ Customer PremisesActive
  • (> 1 V to 10 V) >20 kHz to 50 kHz
2.0 x10¯³.U + 5.0 mVLaboratory/ Customer PremisesActive
  • (> 1 V to 10 V) >50 kHz to 100 kHz
7.9 x10¯³.U + 8.0 mVLaboratory/ Customer PremisesActive
  • (> 1 V to 10 V) >100 kHz to 300 kHz
52 x10¯³.U + 50 mVLaboratory/ Customer PremisesActive
  • (> 10 V to 100 V) 10 Hz to 20 kHz
1.1 x10¯³.U + 30 mVLaboratory/ Customer PremisesActive
  • (> 10 V to 100 V) >20 kHz to 50 kHz
2.0 x10¯³.U + 50 mVLaboratory/ Customer PremisesActive
  • (> 10 V to 100 V) >50 kHz to 100 kHz
7.9 x10¯³.U + 80 mVLaboratory/ Customer PremisesActive
  • (> 100 V to 1000 V) 50 Hz to 20 kHz
1.1 x10¯³.U + 0.30 VLaboratory/ Customer PremisesActive
  • Electrical Measure Mode DC Current
  • Calibration Procedure # AAB-CP-E02 Using Fluke 8846A (I = Measured Current Value)
  • 1 μA to 100 μA
0.90 x10¯³.I + 25 nALaboratory/ Customer PremisesActive
  • >0.1 mA to 1 mA
0.70 x10¯³.I + 50 nALaboratory/ Customer PremisesActive
  • >1 mA to 10 mA
0.90x10¯³.I + 2.0 μALaboratory/ Customer PremisesActive
  • >10 mA to 100 mA
0.70 x10¯³.I + 5.0 μALaboratory/ Customer PremisesActive
  • >0.1 A to 1 A
1.0 x10¯³.I + 0.2 mALaboratory/ Customer PremisesActive
  • >1 A to 3 A
1.4 x10¯³.I + 0.6 mALaboratory/ Customer PremisesActive
  • >3 A to 10 A
1.8 x10¯³.I + 0.8 mALaboratory/ Customer PremisesActive
  • Electrical Measure Mode AC Current
  • (1 μA to 100 μA) 50 Hz to 1 kHz
1.7 x10¯³.I + 0.04 μALaboratory/ Customer PremisesActive
  • (> 0.1 mA to 1 mA) 50 Hz to 1 kHz
1.7 x10¯³.I + 0.40 μALaboratory/ Customer PremisesActive
  • (> 1 mA to 10 mA) 50 Hz to 1 kHz
1.7 x10¯³.I + 4.0 μALaboratory/ Customer PremisesActive
  • (> 10 mA to 100 mA) 50 Hz to 1 kHz
1.6 x10¯³.I + 40 µALaboratory/ Customer PremisesActive
  • Calibration Procedure # AAB-CP-E02 Using Fluke 8846A (I = Measured Current Value)
  • (>0.1 A to 1 A) 50 Hz to 1 kHz
1.8 x10¯³.I + 0.40 mALaboratory/ Customer PremisesActive
  • (>1 A to 3 A) 50 Hz to 1 kHz
2.5 x10¯³.I + 1.8 mALaboratory/ Customer PremisesActive
  • (>3 A to 10 A) 10 Hz to 10 kHz
2.5 x10¯³.I + 6.0 mALaboratory/ Customer PremisesActive
  • Electrical Measure Mode Resistance
  • Calibration Procedure # AAB-CP-E02 Using Fluke 8846A (R= Measured Resistance Value)
  • 1 Ω to 10 Ω
0.50 x10¯³.R + 3.0 mΩLaboratory/ Customer PremisesActive
  • >10 Ω to 100 Ω
0.20 x10¯³.R + 4.0 mΩLaboratory/ Customer PremisesActive
  • >0.1 kΩ to 1 kΩ
0.20 x10¯³.R + 10 mΩLaboratory/ Customer PremisesActive
  • >1 kΩ to 10 kΩ
0.20 x10¯³.R + 0.10 ΩLaboratory/ Customer PremisesActive
  • >10 kΩ to 100 kΩ
0.20 x10¯³.R + 1.0 ΩLaboratory/ Customer PremisesActive
  • >0.1 MΩ to 1 MΩ
0.20 x10¯³.R + 10 ΩLaboratory/ Customer PremisesActive
  • >1 MΩ to 10 MΩ
0.50 x10¯³.R + 0.10 kΩLaboratory/ Customer PremisesActive
  • >10 MΩ to 100 MΩ
9.4 x10¯³.R + 10 kΩLaboratory/ Customer PremisesActive
  • >0.1 GΩ to 1 GΩ
24 x10¯³.R + 0.10 MΩLaboratory/ Customer PremisesActive
  • Electrical Measure Mode Capacitance
  • Calibration Procedure # AAB-CP-E02 Using Fluke 8846A (C= Measured Capacitance Value)
  • 0.1 nF to 1 nF
52 x10¯³.C + 8.0 pFLaboratory/ Customer PremisesActive
  • >1 nF to 10 nF
18 x10¯³.C + 50 pFLaboratory/ Customer PremisesActive
  • >10 nF to 100 nF
18 x10¯³.C + 0.50 nFLaboratory/ Customer PremisesActive
  • >0.1 μF to 1 μF
18 x10¯³.C + 5.0 nFLaboratory/ Customer PremisesActive
  • >1 μF to 10 μF
18 x10¯³.C + 50 nFLaboratory/ Customer PremisesActive
  • >10 μF to 100 μF
18 x10¯³.C + 0.50 μFLaboratory/ Customer PremisesActive
  • >0.1 mF to 1mF
18 x10¯³.C + 5.0 μFLaboratory/ Customer PremisesActive
  • >1 mF to 10 mF
18 x10¯³.C + 50 µFLaboratory/ Customer PremisesActive
  • >10 mF to 100 mF
49 x10¯³.C + 0.20 mFLaboratory/ Customer PremisesActive
  • Electrical Measure Mode Frequency
  • Calibration Procedure # AAB-CP-E02 Using Fluke 8846A (F = Measured Frequency Value)
  • 3 Hz to 10 Hz
0.60 x10¯³.FLaboratory/ Customer PremisesActive
  • >10 Hz to 40 Hz
0.40 x10¯³.FLaboratory/ Customer PremisesActive
  • >40 Hz to 300 kHz
0.20 x10¯³.FLaboratory/ Customer PremisesActive
  • >300 kHz to 1 MHz
0.20 x10¯³.FLaboratory/ Customer PremisesActive
  • Calibration of RTD Measuring Instruments - PT 385,100Ω
  • Calibration Procedure # AAB-CP-E01 Using Fluke 5522A
  • -200 °C to -80°C
0.11°CLaboratory/ Customer PremisesActive
  • >-80°C to 0°C
0.10°CLaboratory/ Customer PremisesActive
  • >0°C to 100°C
0.10°CLaboratory/ Customer PremisesActive
  • >100°C to 300°C
0.14°CLaboratory/ Customer PremisesActive
  • >300°C to 600°C
0.14°CLaboratory/ Customer PremisesActive
  • >600°C to 800°C
0.17°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple measuring Instruments -Type B
  • Calibration Procedure # AAB-CP-E01 Using Fluke 5522A
  • 600°C to 800°C
0.52°CLaboratory/ Customer PremisesActive
  • >800°C to 1000°C
0.41°CLaboratory/ Customer PremisesActive
  • >1000°C to 1550°C
0.37°CLaboratory/ Customer PremisesActive
  • >1550°C to 1820°C
0.41°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple measuring Instruments -Type C
  • Calibration Procedure # AAB-CP-E01 Using Fluke 5522A
  • 0°C to 150°C
0.37°CLaboratory/ Customer PremisesActive
  • >150°C to 650°C
0.33°CLaboratory/ Customer PremisesActive
  • >650°C to 1000°C
0.38°CLaboratory/ Customer PremisesActive
  • >1000°C to 1800°C
0.59°CLaboratory/ Customer PremisesActive
  • >1800°C to 2316°C
0.98°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple measuring Instruments -Type E
  • Calibration Procedure # AAB-CP-E01 Using Fluke 5522A
  • -250°C to -100°C
0.59°CLaboratory/ Customer PremisesActive
  • >-100°C to -25°C
0.22°CLaboratory/ Customer PremisesActive
  • >-25°C to 350°C
0.20°CLaboratory/ Customer PremisesActive
  • >350°C to 650°C
0.23°CLaboratory/ Customer PremisesActive
  • >650°C to 1000°C
0.28°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple measuring Instruments -Type J
  • -210°C to -100°C
0.33°CLaboratory/ Customer PremisesActive
  • >-100°C to -30°C
0.21°CLaboratory/ Customer PremisesActive
  • >-30°C to 150°C
0.19°CLaboratory/ Customer PremisesActive
  • >150°C to 760°C
0.22°CLaboratory/ Customer PremisesActive
  • >760°C to 1200°C
0.28°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple measuring Instruments -Type K
  • -200°C to -100°C
0.40°CLaboratory/ Customer PremisesActive
  • >-100°C to -25°C
0.24°CLaboratory/ Customer PremisesActive
  • >-25°C to 120°C
0.22°CLaboratory/ Customer PremisesActive
  • >120°C to 1000°C
0.33°CLaboratory/ Customer PremisesActive
  • >1000°C to 1372°C
0.48°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple measuring Instruments -Type L
  • -200°C to -100°C
0.44°CLaboratory/ Customer PremisesActive
  • >-100°C to 800°C
0.33°CLaboratory/ Customer PremisesActive
  • >800°C to 900°C
0.24°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple measuring Instruments -Type N
  • -200°C to -100°C
0.48°CLaboratory/ Customer PremisesActive
  • >-100°C to -25°C
0.28°CLaboratory/ Customer PremisesActive
  • >-25°C to 120°C
0.25°CLaboratory/ Customer PremisesActive
  • >120°C to 410°C
0.25°CLaboratory/ Customer PremisesActive
  • >410°C to 1300°C
0.34°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple measuring Instruments -Type R
  • 0°C to 250°C
0.67°CLaboratory/ Customer PremisesActive
  • >250°C to 400°C
0.43°CLaboratory/ Customer PremisesActive
  • >400°C to 1000°C
0.41°CLaboratory/ Customer PremisesActive
  • >1000°C to 1767°C
0.48°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple measuring Instruments -Type S
  • 0°C to 250°C
0.56°CLaboratory/ Customer PremisesActive
  • >250°C to 1000°C
0.44°CLaboratory/ Customer PremisesActive
  • >1000°C to 1400°C
0.45°CLaboratory/ Customer PremisesActive
  • >1400°C to 1767°C
0.55°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple measuring Instruments -Type T
  • -250°C to -150°C
0.74°CLaboratory/ Customer PremisesActive
  • >-150°C to 0°C
0.30°CLaboratory/ Customer PremisesActive
  • >0°C to 120°C
0.23°CLaboratory/ Customer PremisesActive
  • >120°C to 400°C
0.21°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple measuring Instruments -Type U
  • >-200°C to 0°C
0.66°CLaboratory/ Customer PremisesActive
  • >0°C to 600°C
0.44°CLaboratory/ Customer PremisesActive
  • RTD Simulation PT 385,100Ω
  • Calibration Procedure # AAB-CP-E02 Using Fluke 8846A
  • -200 °C to -100°C
0.10°CLaboratory/ Customer PremisesActive
  • >-100°C to 0°C
0.10°CLaboratory/ Customer PremisesActive
  • >0°C to 100°C
0.10°CLaboratory/ Customer PremisesActive
  • >100°C to 300°C
0.14°CLaboratory/ Customer PremisesActive
  • >300°C to 600°C
0.16°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple Simulators - Type B
  • 600°C to 800°C
0.57°CLaboratory/ Customer PremisesActive
  • >800°C to 1000°C
0.47°CLaboratory/ Customer PremisesActive
  • >1000°C to 1550°C
0.43°CLaboratory/ Customer PremisesActive
  • >1550°C to 1820°C
0.46°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple Simulators - Type C
  • 0°C to 150°C
0.43°CLaboratory/ Customer PremisesActive
  • >150°C to 650°C
0.39°CLaboratory/ Customer PremisesActive
  • >650°C to 1000°C
0.44°CLaboratory/ Customer PremisesActive
  • >1000°C to 1800°C
0.63°CLaboratory/ Customer PremisesActive
  • >1800°C to 2316°C
1.00°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple Simulators - Type E
  • -250°C to -100°C
0.62°CLaboratory/ Customer PremisesActive
  • >-100°C to -25°C
0.30°CLaboratory/ Customer PremisesActive
  • >-25°C to 350°C
0.30°CLaboratory/ Customer PremisesActive
  • >350°C to 650°C
0.31°CLaboratory/ Customer PremisesActive
  • >650°C to 1000°C
0.35°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple Simulators - Type J
  • -210°C to -100°C
0.39°CLaboratory/ Customer PremisesActive
  • >-100°C to -30°C
0.30°CLaboratory/ Customer PremisesActive
  • >-30°C to 150°C
0.30°CLaboratory/ Customer PremisesActive
  • >150°C to 760°C
0.32°CLaboratory/ Customer PremisesActive
  • >760°C to 1200°C
0.37°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple Simulators - Type K
  • -200°C to -100°C
0.45°CLaboratory/ Customer PremisesActive
  • >-100°C to -25°C
0.31°CLaboratory/ Customer PremisesActive
  • >-25°C to 120°C
0.31°CLaboratory/ Customer PremisesActive
  • >120°C to 1000°C
0.39°CLaboratory/ Customer PremisesActive
  • >1000°C to 1372°C
0.53°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple Simulators - Type L
  • -200°C to -100°C
0.49°CLaboratory/ Customer PremisesActive
  • >-100°C to 800°C
0.39°CLaboratory/ Customer PremisesActive
  • >800°C to 900°C
0.32°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple Simulators - Type N
  • -200°C to -100°C
0.52°CLaboratory/ Customer PremisesActive
  • >-100°C to -25°C
0.35°CLaboratory/ Customer PremisesActive
  • >-25°C to 120°C
0.33°CLaboratory/ Customer PremisesActive
  • >120°C to 410°C
0.33°CLaboratory/ Customer PremisesActive
  • >410°C to 1300°C
0.40°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple Simulators - Type R
  • 0°C to 250°C
0.70°CLaboratory/ Customer PremisesActive
  • >250°C to 400°C
0.48°CLaboratory/ Customer PremisesActive
  • >400°C to 1000°C
0.46°CLaboratory/ Customer PremisesActive
  • >1000°C to 1767°C
0.53°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple Simulators - Type S
  • 0°C to 250°C
0.60°CLaboratory/ Customer PremisesActive
  • >250°C to 1000°C
0.49°CLaboratory/ Customer PremisesActive
  • >1000°C to 1400°C
0.50°CLaboratory/ Customer PremisesActive
  • >1400°C to 1767°C
0.59°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple Simulators - Type T
  • -250°C to -150°C
0.76°CLaboratory/ Customer PremisesActive
  • >-150°C to 0°C
0.36°CLaboratory/ Customer PremisesActive
  • >0°C to 120°C
0.31°CLaboratory/ Customer PremisesActive
  • >120°C to 400°C
0.30°CLaboratory/ Customer PremisesActive
  • Calibration of Thermocouple Simulators - Type U
  • -200°C to 0°C
0.69°CLaboratory/ Customer PremisesActive
  • >0°C to 600°C
0.40°CLaboratory/ Customer PremisesActive
  • RCD Trip Time
  • Calibration Procedure # AAB-CP-E01 Using Fluke 5320A
  • 10 ms to 510 ms
0.50 msLaboratory/ Customer PremisesActive
  • >510 ms to 5.0 s
1.5 msLaboratory/ Customer PremisesActive
  • Leakage current
  • 100 µA to 300 µA
4.0 µALaboratory/ Customer PremisesActive
  • >300 µA to 10 mA
50 µALaboratory/ Customer PremisesActive
  • >10 mA to 30 mA
0.18 mALaboratory/ Customer PremisesActive
  • RCD Current
  • 0.1 mA to 10 mA
0.60 mALaboratory/ Customer PremisesActive
  • >10 mA to 30 mA
1.8 mALaboratory/ Customer PremisesActive
  • >30 mA to 100 mA
5.8 mALaboratory/ Customer PremisesActive
  • >100 mA to 300 mA
17.4 mALaboratory/ Customer PremisesActive
  • >300 mA to 2500 mA
30 mALaboratory/ Customer PremisesActive
  • Loop Impedence
  • 0.025 Ω to 0.33 Ω
10 mΩLaboratory/ Customer PremisesActive
  • >0.33 Ω to 18 Ω
0.12 ΩLaboratory/ Customer PremisesActive
  • >18 Ω to 180 Ω
1.2 ΩLaboratory/ Customer PremisesActive
  • >180 Ω to 1000 Ω
6.0 ΩLaboratory/ Customer PremisesActive
  • >1000 Ω to 1800 Ω
12 ΩLaboratory/ Customer PremisesActive
Time and Frequency
  • Stop Watch/Timer
  • Calibration Procedure # AAB-CP-E07 (Comparision Method Using Standard Stop Watch)
  • 1 sec to 30 min
0.70 secLaboratory/ Customer PremisesActive
  • above 30 min
1.1 secLaboratory/ Customer PremisesActive
  • RPM/Speed
  • Calibration Procedure # AAB-CP-E01 (Comparision Method Using Fluke 5522A)
  • 6 RPM to 999 RPM
2.3 RPMLaboratory/ Customer PremisesActive
  • 1000 RPM to 9999 RPM
3.5 RPMLaboratory/ Customer PremisesActive
  • 10000 RPM to 20000 RPM
4.7 RPMLaboratory/ Customer PremisesActive
  • 20001 RPM to 50000 RPM
12 RPMLaboratory/ Customer PremisesActive
  • 50001 RPM to 99960RPM
24 RPMLaboratory/ Customer PremisesActive