Danway Calibration and Measurements Lab LLC

Initial Accreditation Date:Jun 30 , 2003

معلومات الاتصال

العنوان

Alquoz ind 3, Dubai, United Arab Emirates

صندوق بريد / الرمز البريدي

50048

البريد الإلكتروني

lab@danwayirs.com hazeebudeen.k@danwayirs.com

الموقع الإلكتروني

www.danway.ae

رقم الهاتف

+971 050 625 1871

رقم الجوال

+971 04 347 3232

المجال الرئيسي

Calibration Laboratories

ساري منذ:Sep 13 , 2024

Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Balance & Scale
  • Top loading weighing scale
Active
Dimensions
  • All types of Caliper Digital / Dial / Vernier
  • DCML-D/WI-001 Based on BS EN ISO 13385-1 For determining error of indicated size Comparison with gauge blocks/calliper checker
  • 0 mm to 300 mm
26 µmLaboratoryActive
  • 300 mm to 600 mm
30 µmLaboratoryActive
  • External Micrometer
  • DCML-D/WI-002 based on ISO 3611 For determining error of indicated size Comparison with gauge blocks
  • 0 mm to 25 mm
2.5 µmLaboratoryActive
  • Dial gauges (Digital & Analogue)
  • DCML-D/WI-003 based on ISO 463 / JIS B 7503 For determining error of indicated displacement, Comparison with dial gauge calibrator
  • 0 mm to 100 mm
4 µmLaboratoryActive
  • LVDT with Indicator
  • DCML-D/WI-003 For determining error of indicated displacement, Comparison with dial gauge calibrator
8 µmLaboratoryActive
  • Tapes and Scales Calibrator
  • DCML-D/WI-005 In-house method based on manufacturer’s Guide For determining error of indicated displacement, Comparison with reference measuring tape
  • 0 mm to 1000 mm
0.4 mmLaboratory/ Customer PremisesActive
  • Calibration of Scales (Steel Rules)
  • DCML-D/WI-004 Measurement of line spacing using length measuring machine equipped with optical magnification unit.
0.67 mmLaboratoryActive
  • Steel Tapes
  • DCML-D/WI-00 Measurement of line spacing using length measuring machine equipped with optical magnification unit. Stitching is carried out after length of 1 m.
  • 0 m to 5 m
1.5 mmLaboratoryActive
  • DCML-D/WI-004 Measurement of line spacing using length measuring machine equipped with optical magnification unit. Stitching is carried out after length of 1 m.
  • 5 m to 10 m
2.2 mmLaboratoryActive
  • 10 m to 20 m
3.0 mmLaboratoryActive
  • Test Sieves Aperture Size
  • DCML-D/WI-008 Based on ISO 3310-1 / BS 410-1 For determining aperture size Using Profile Projector
  • 0.02 mm to 125 mm
11 µmLaboratoryActive
Mass and Balance
  • Top loading weighing scale
  • ASTM E898-88 :2020
  • 0 to 210 g
0.0005 gCustomer PremisesActive
  • >210 g to 410 g
0.001 gCustomer PremisesActive
  • > 410 g to 2 kg
0.01 gCustomer PremisesActive
  • >2 kg to 6 kg
0.04 gCustomer PremisesActive
  • >6 kg to 15 kg
0.1 gCustomer PremisesActive
  • >15 kg to 32 kg
0.2 gCustomer PremisesActive
  • >32 kg to 60 kg
0.6 gCustomer PremisesActive
  • >60 kg to 100 kg
5 gCustomer PremisesActive
  • >100 kg to 150 kg
50 gCustomer PremisesActive
  • >150 kg to 500 kg
0.12 kgCustomer PremisesActive
  • >500 kg to 1000 kg
0.2 kgCustomer PremisesActive
  • >1000 kg to 5000 kg
1.5 kgCustomer PremisesActive
  • M1 Mass calibration
  • OIML R 111 -1 :2004
  • 50000 g
0.8 gLaboratoryActive
  • 20000 g
0.3 gLaboratoryActive
  • 10000 g
0.16 gLaboratoryActive
  • 5000 g
0.08 gLaboratoryActive
  • 2000 g
0.03 gLaboratoryActive
  • 1000 g
016 mgLaboratoryActive
  • 500 g
08 mgLaboratoryActive
  • 200 g
3 mgLaboratoryActive
  • 100 g
1.6 mgLaboratoryActive
  • 50 g
1 mgLaboratoryActive
  • 20 g
0.8 mgLaboratoryActive
  • 10 g
0.6 mgLaboratoryActive
  • 5 g
0.5 mgLaboratoryActive
  • 2 g
0.4 mgLaboratoryActive
  • 1 g
0.3 mgLaboratoryActive
  • Mass Calibration Conventional Mass
  • Standard Weights as per OIML R111-1 : 2004
  • 500 kg
25 gLaboratoryActive
  • 1000 kg
50 gLaboratoryActive
  • Truck Scales
  • DCML-M/WI-010 in accordance to Euramet cg 18 v4 :2015
  • 0 to 20 ton
22 kgCustomer PremisesActive
  • > 20 ton to 40 ton
32 kgCustomer PremisesActive
  • > 40 ton to 60 ton
45 kgCustomer PremisesActive
  • > 60 ton to 80 ton
56 kgCustomer PremisesActive
  • > 80 ton to 100 ton
65 kgCustomer PremisesActive
  • > 100 ton to 120 ton
73 kgCustomer PremisesActive
  • Batching Plants: Calibration of concrete and Asphalt batching plants, Hopper scale and Tank scale
  • ASTM C94/C94M :2021 & NIST Handbook 44 :2018
  • 0 to 1000 kg
0.082 kgCustomer PremisesActive
  • >1000 to 5000 kg
1.2 kgCustomer PremisesActive
  • >5000 kg to 16.5 ton
5.8 kgCustomer PremisesActive
Pressure
  • Analogue or digital Pressure gauges of class up to 0.1% Using pressure comparator. Medium : Gas
  • Work instruction DCML-P/WI-001 based on DKD R 6-1 and BS EN 837-1
  • -95 kPa up to 0 kPa
0.2 kPaLaboratory/ Customer PremisesActive
  • 0 kPa Up to 2000 kPa
1 kPaLaboratory/ Customer PremisesActive
  • > 2 MPa Up To 7 MPa
7 kPaLaboratory/ Customer PremisesActive
  • Analogue or digital Pressure gauges of class up to 0.1% Using Dead weight tester. Medium : Oil
  • 0.3 MPa Up to 6 MPa
0.11 % of Reading.LaboratoryActive
  • > 6 MPa Up to 120 MPa
0.04 % of ReadingLaboratoryActive
  • Analogue or digital Pressure gauges of class up to 0.1% Using Reference gauge Medium : Oil
  • 0 MPa Up to 70 MPa
0.13% of ReadingLaboratory/ Customer PremisesActive
Force
  • Calibration of Force measuring devices (soil testing rings, proving rings or load cells with indicator)
  • Work Instruction No : DCML-F/WI-002 based on BS 1377-1
  • 200 N up to 200 kN in Compression
1.0 %LaboratoryActive
  • Verification / Calibration of testing machines
  • BS EN ISO 7500-1 & ASTM E4
  • 100 kN up to 3000 kN in Compression
0.30 %Customer PremisesActive
  • 0.2 kN up to 100 kN in Compression and Tension
0.18 %Customer PremisesActive
  • 10 N up to 200 N in Compression and Tension
0.10 %Customer PremisesActive
  • Verification/ Calibration of Poing Load Testers
  • Work Instruction DCML-F/WI-001 Based on ISO 7500-1
  • 1 kN up to 100 kN in Compression
1.0 %Laboratory/ Customer PremisesActive
  • Calibration of Pull out and Pull off Tester
  • DCML-F/WI-003 based on ASTM C900
  • 0.2 kN up to 100 kN in Tension
0.3 %LaboratoryActive
  • CBR and Marshall Testing Machines
  • Work Instruction DCML-F/WI-001 Based on ISO 7500-1 & ASTM E4
  • 0.2 kN up to 100 kN in Compression
0.3 %Laboratory/ Customer PremisesActive
  • Calibration of force and load measuring devices with indicator for industrial applications
  • DCML-F/WI-006 based on standard calibration of BS8422
  • 100 N up to 100 kN in Compression and Tension
1.0 %LaboratoryActive
  • 100 kN up to 1 MN in Compression and Tension
1.3 %LaboratoryActive
  • Calibration of Hydraulic Jack with indicator
  • DCML-F/WI-004
  • 0.2 kN £ up to £ 100 kN in Compression
0.6 %LaboratoryActive
  • 100 kN £ up to £ 1 MN in Compression
1.0 %LaboratoryActive
  • Compression Testing Machines for Concrete
  • DCML-F/WI-007 based on BS EN 12390-4 Performance Test (Stability Verification)
  • 200 kN and 2000 kN Alignment of Upper Machine Platen
N/ACustomer PremisesActive
Temperature
  • Liquid-in-glass thermometers
  • DCML-T/WI-001
  • ­30 °Ϲ up to 125 °Ϲ
0.2 °ϹLaboratoryActive
  • Digital thermometer with PRT or NTC sensor
  • DCML-T/WI 001 * minimum temperature= ambient ­ 40 °Ϲ
  • ­30 °Ϲ* up to 300 °Ϲ
0.2 °ϹLaboratoryActive
  • ­20 °Ϲ* up to 300 °Ϲ
0.3 °ϹCustomer PremisesActive
  • 30 °Ϲ to 300 °Ϲ
0.2 °ϹLaboratoryActive
  • 300 °Ϲ to 500 °Ϲ
1.9 °ϹLaboratoryActive
  • Digital thermometer with TC sensor
  • DCML-T/WI 001 * minimum temperature = ambient ­ 40 °Ϲ
  • ­20 °Ϲ* to 300 °Ϲ
0.8 °ϹLaboratory/ Customer PremisesActive
  • 30 °Ϲ to 300 °Ϲ
0.7 °ϹLaboratoryActive
  • 300 °Ϲ to 500 °Ϲ
2.0 °ϹLaboratoryActive
  • Calibration of thermometer with built in sensors and mercury maximum minimum thermometers
  • DCML-T/ WI 005
  • 10 °C up to 60 °C
0.5 °ϹLaboratoryActive
  • Climatic Chamber (9 points)
  • DCML-T/WI-002 DKD-R5-7
  • 30 °C up to 180 °C
0.6 °ϹLaboratory/ Customer PremisesActive
  • Measuring location in climatic chamber
  • DCML-T/WI-002 & DKD-R 5-7 method C
  • 30 °Ϲ to 180 °Ϲ
0.4 °ϹLaboratory/ Customer PremisesActive
  • Water bath, incubators (5 points)
  • DCML-T/WI-002 DKD-R5-7
  • 5 °Ϲ up to 95 °Ϲ
0.4 °ϹLaboratory/ Customer PremisesActive
  • Freezer / Chiller (9 points)
  • ­30 °Ϲ up to 95 °Ϲ
0.6 °ϹLaboratory/ Customer PremisesActive
  • Measuring location in freezer or chiller
  • DCML-T/WI-002 & DKD-R 5-7 method C
  • ­30 °Ϲ to 95 °Ϲ
0.4 °ϹLaboratory/ Customer PremisesActive
  • Measuring location in Furnace (1 point)
  • DCML-T/WI-002 DKD-R5-7 (Muffle Furnace)
  • 30 °Ϲ up to 180 °Ϲ
0.8 °ϹLaboratory/ Customer PremisesActive
  • 180 °Ϲ up to 300 °Ϲ
0.8 °ϹLaboratory/ Customer PremisesActive
  • 300 °Ϲ up to 800 °Ϲ
1.0 °ϹLaboratory/ Customer PremisesActive
  • 800 °Ϲ up to 1100 °Ϲ
2.0 °ϹLaboratory/ Customer PremisesActive
  • Calibration of infrared thermometers
  • DCML-T/ WI 004
  • ­35 °Ϲ up to 100 °Ϲ
1 °ϹLaboratoryActive
  • 100 °Ϲ up to 150 °Ϲ
2 °ϹLaboratoryActive
  • Type K thermocouple
  • DCML-E/WI-007
  • ­200 °Ϲ to ­100 °Ϲ
0.50 Klaboratory/ customer premisesActive
  • ­100 °Ϲ to 1372 °Ϲ
0.36 Klaboratory/ customer premisesActive
  • Type J thermocouple
  • ­210 °Ϲ to -50 °Ϲ
0.30 Klaboratory/ customer premisesActive
  • ­50 °Ϲ to 1200 °Ϲ
0.40 Klaboratory/ customer premisesActive
  • Type T thermocouple
  • ­200 °Ϲ to 100 °Ϲ
0.40 Klaboratory/ customer premisesActive
  • 100 °Ϲ to 400 °Ϲ
0.30 Klaboratory/ customer premisesActive
  • Type R thermocouple
  • ­50 °Ϲ to 50 °Ϲ
2,0 Klaboratory/ customer premisesActive
  • 50 °Ϲ to 250 °Ϲ
1.4 Klaboratory/ customer premisesActive
  • 250 °Ϲ to 1768 °Ϲ
1.2 Klaboratory/ customer premisesActive
  • Type S thermocouple
  • ­50 °Ϲ to 500 °Ϲ
1.8 Klaboratory/ customer premisesActive
  • 500 °Ϲ to 1768 °Ϲ
1.2 Klaboratory/ customer premisesActive
  • Type B thermocouple
  • 300 °Ϲ to 800 °Ϲ
3.0 Klaboratory/ customer premisesActive
  • 800 °Ϲ to 1820 °Ϲ
1.6 Klaboratory/ customer premisesActive
  • Type E thermocouple
  • ­200 °Ϲ to 0 °Ϲ
0.40 Klaboratory/ customer premisesActive
  • 0 °Ϲ to 1000 °Ϲ
0.24 Klaboratory/ customer premisesActive
  • Type N thermocouple
  • ­200 °Ϲ to 0 °Ϲ
0.80 Klaboratory/ customer premisesActive
  • 0 °Ϲ to 600 °Ϲ
0.30 Klaboratory/ customer premisesActive
  • 600 °Ϲ to 1300 °Ϲ
0.40 Klaboratory/ customer premisesActive
  • PT 100
  • ­140 °Ϲ to 50 °Ϲ
0.50 Klaboratory/ customer premisesActive
  • 50 °Ϲ to 850 °Ϲ
0,41 K +1,8mK/K*Tlaboratory/ customer premisesActive
Electrical
  • DC Voltage meter
  • Work Instruction DCML-E/WI-001 (Based on Euramet calibration guide for the calibration of multimeters-cg-15)
  • 0 mV to 200 mV
17 µVLaboratory/ Customer premisesActive
  • > 200 mV up to 2 V
1.1 mVLaboratory/ Customer premisesActive
  • > 2 V up to 20 V
1.3 mVLaboratory/ Customer premisesActive
  • >20 V up to 200 V
7 mVLaboratory/ Customer premisesActive
  • > 200 V to 1050 V
0.16 VLaboratory/ Customer premisesActive
  • DC Current Meter
  • 0 µA to 200 µA
64 nALaboratory/ Customer premisesActive
  • > 0.2 mA to 2 mA
1.1 µALaboratory/ Customer premisesActive
  • > 2 mA to 20 mA
3.0 µALaboratory/ Customer premisesActive
  • > 20 mA to 200 mA
0.04 mALaboratory/ Customer premisesActive
  • > 0.2 A to 2 A
0.4 mALaboratory/ Customer premisesActive
  • 2 A to 22 A
4.0 mALaboratory/ Customer premisesActive
  • AC Voltage meter
  • 0 mV to 200 mV
0.30 mVLaboratory/ Customer premisesActive
  • > 0.2 V to 2 V
2.0 mVLaboratory/ Customer premisesActive
  • > 20 V to 200 V
0.17 VLaboratory/ Customer premisesActive
  • > 200 V to 1050 V
1.2 VLaboratory/ Customer premisesActive
  • AC Current Meter
  • 0 µA to 200 µA
0.51 µALaboratory/ Customer premisesActive
  • > 0.2 mA to 2 mA
2.1 µALaboratory/ Customer premisesActive
  • > 2 mA to 20 mA
0.11 mALaboratory/ Customer premisesActive
  • > 20 mA to 200 mA
0.36 mALaboratory/ Customer premisesActive
  • > 0.2 A to 2 A
3.3 mALaboratory/ Customer premisesActive
  • > 2 A to 20 A
58 mALaboratory/ Customer premisesActive
  • Resistance meter using Decade Resistance
  • 10 Ω
100 MωLaboratory/ Customer premisesActive
  • 100 Ω
1.5 mΩLaboratory/ Customer premisesActive
  • 1 kΩ
10 ΩLaboratory/ Customer premisesActive
  • 10 kΩ
0.1 ΩLaboratory/ Customer premisesActive
  • 100 kΩ
1.0 ΩLaboratory/ Customer premisesActive
  • 1 MΩ
0.02 kΩLaboratory/ Customer premisesActive
  • 10 MΩ
12 kΩLaboratory/ Customer premisesActive
  • 100 MΩ
1.2 MΩLaboratory/ Customer premisesActive
  • 1 GΩ
0.12 GΩLaboratory/ Customer premisesActive
  • Resistance meter using Simulated Resistance
  • 0 Ω to 400 Ω
0.30 ΩLaboratory/ Customer premisesActive
  • 0.4 KΩ to 4 KΩ
2.0 ΩLaboratory/ Customer premisesActive
  • 4 KΩ to 40 KΩ
15 ΩLaboratory/ Customer premisesActive
  • Capacitance meter
  • 1 nF @ 1 kHz
14 pFLaboratory/ Customer premisesActive
  • 10 nF @ 1 kHz
36 pFLaboratory/ Customer premisesActive
  • 20 nF @ 1 kHz
60 pFLaboratory/ Customer premisesActive
  • 50 nF @ 1 kHz
0.13 nFLaboratory/ Customer premisesActive
  • 100 nF @ 1 kHz
0.26 nFLaboratory/ Customer premisesActive
  • 200 nF @ 1 kHz
0.48 nFLaboratory/ Customer premisesActive
  • 500 nF @ 1 kHz
1.2 nFLaboratory/ Customer premisesActive
  • 1 µF @ 1 kHz
2.4 nFLaboratory/ Customer premisesActive
  • Digital Frequency meter
  • 0 Hz to 50 Hz
0.001 HzLaboratory/ Customer premisesActive
  • > 50 Hz to 200Hz
0.005HzLaboratory/ Customer premisesActive
  • > 200 Hz to 10kHz
0.001 kHzLaboratory/ Customer premisesActive
  • > 2 10 kHz to 100kHz
0.002kHzLaboratory/ Customer premisesActive
  • > 2 100 kHz to500 kHz
0.012kHzLaboratory/ Customer premisesActive
  • > 500 kHz to 10 MHz
0.001MHzLaboratory/ Customer premisesActive
  • Digital period
  • Upto100 ns
0.003nsLaboratory/ Customer premisesActive
  • >100 ns to 10µs
0.001µsLaboratory/ Customer premisesActive
  • >10µs to 100µs
0.002µsLaboratory/ Customer premisesActive
  • >100µs to 1ms
0.001µsLaboratory/ Customer premisesActive
  • >1ms to 100 ms
0.002msLaboratory/ Customer premisesActive
  • >100ms to 1s
0.001msLaboratory/ Customer premisesActive
  • Clamp meter
  • 1100 A AC @ 50 Hz
4.5 ALaboratory/ Customer premisesActive
  • 1100 A DC
3.7 ALaboratory/ Customer premisesActive
  • Tachometer
  • 120000 RPM
1.8 RPMLaboratory/ Customer premisesActive
  • DC Voltage
  • Work instruction DCML-E/WI-002
  • 0 mV to 100 mV
17 μVLaboratory/ Customer premisesActive
  • > 100 mV to 1 V
1.1 mVLaboratory/ Customer premisesActive
  • > 1 V to 10 V
1.3 mVLaboratory/ Customer premisesActive
  • > 10 V to 100 V
7.4 mVLaboratory/ Customer premisesActive
  • > 100 V to 1000 V
8.4 mVLaboratory/ Customer premisesActive
  • DC Current Measure
  • 0 mA to 10 mA
3.0 μALaboratory/ Customer premisesActive
  • > 10 mA to 100 mA
5.0 μALaboratory/ Customer premisesActive
  • > 100 mA to 1 A
1.3 mALaboratory/ Customer premisesActive
  • > 1 A to 3 A
3.2 mALaboratory/ Customer premisesActive
  • AC Voltage 50Hz
  • 0 mV to 100 mV
0.1 mVLaboratory/ Customer premisesActive
  • > 100 mV to 1 V
0.5 mVLaboratory/ Customer premisesActive
  • > 1 V to 10 V
2.0 mVLaboratory/ Customer premisesActive
  • >10 V to 100 V
0.1 VLaboratory/ Customer premisesActive
  • >100 V to 500 V
0.5 VLaboratory/ Customer premisesActive
  • >500 V to 750 V
0.7 VLaboratory/ Customer premisesActive
  • AC Current
  • 0 A to 1 A (10 Hz to 5 kHz)
1.4 mALaboratory/ Customer premisesActive
  • > 1 A to 3 A (10 Hz to 5 kHz)
0.1 ALaboratory/ Customer premisesActive
  • Resistance
  • 0 Ω to 100 Ω
16 mΩLaboratory/ Customer premisesActive
  • > 100 Ω to 1 kΩ
0.5 ΩLaboratory/ Customer premisesActive
  • > 1 kΩ to 10 kΩ
1.0 ΩLaboratory/ Customer premisesActive
  • > 10 kΩ to 100 kΩ
10 ΩLaboratory/ Customer premisesActive
  • > 100 kΩ to 1 MΩ
0.2 kΩLaboratory/ Customer premisesActive
  • Insulation Tester Resistance
  • Work instruction DCML-E/WI-003 Based on Guide line TG 02-01 of SANAS
  • 10 MΩ
1.3 kΩLaboratory/ Customer premisesActive
  • 50 MΩ
10 kΩLaboratory/ Customer premisesActive
  • 100 MΩ
10 kΩLaboratory/ Customer premisesActive
  • 400 MΩ
0.10 MΩLaboratory/ Customer premisesActive
  • 1 GΩ
0.20 MΩLaboratory/ Customer premisesActive
  • 4 GΩ
1.2 MΩLaboratory/ Customer premisesActive
  • 10 GΩ
5.3 MΩLaboratory/ Customer premisesActive
  • 100 GΩ
12 MΩLaboratory/ Customer premisesActive
Humidity
  • Hygrometer
  • DCML-H/WI-00x
  • 10°C to 60°C
0.2 KLaboratoryActive
  • 25%rH to 90%rH at 20°C to 30°C
2,5 % RHLaboratoryActive
  • 25%rH to 90%rH at 30°C to 60°C
3,0 % RHLaboratoryActive
Time
  • Time
  • DCML-TI/WI-001 based on NIST Pub. 960-12:2009
  • 0 up to 30 min
0.5 SecLaboratory and customer premisesActive
  • 30 min up to 1 hour
0.81 SecLaboratory and customer premisesActive