Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Balance & Scale
  • Top loading weighing scale
Active
Balance & Mass Calibration
  • Weighing Scale
  • Metromac Calibration Procedure MQS 03 C 75 based on ASTM898:20.
  • Upto 600 g
1.4 mgCustomer PremisesActive
  • > 600 g to 3000 g
14 mgCustomer PremisesActive
  • > 3 kg to 60 kg
0.14 gCustomer PremisesActive
  • >60 kg to 100 kg
1.2 gCustomer PremisesActive
  • >100 kg to 300 kg
12 gCustomer PremisesActive
  • > 300 kg to 500 kg
0.12 KgCustomer PremisesActive
  • OIML Masses Class F1 and Lower
  • Using E2 class W.I. MQS 03 C89 based on OIML R 111:2004
  • 1 mg
0.01 mgMetromac PremisesActive
  • 2 mg
0.01 mgMetromac PremisesActive
  • 5 mg
0.01 mgMetromac PremisesActive
  • 10 mg
0.01 mgMetromac PremisesActive
  • 20 mg
0.01 mgMetromac PremisesActive
  • 50 mg
0.01 mgMetromac PremisesActive
  • 100 mg
0.01 mgMetromac PremisesActive
  • 200 mg
0.01 mgMetromac PremisesActive
  • 500 mg
0.01 mgMetromac PremisesActive
  • 1 g
0.01 mgMetromac PremisesActive
  • Using E2 class masss by comparison method
  • 2 g
0.01 mgMetromac PremisesActive
  • 5 g
0.02 mgMetromac PremisesActive
  • 10 g
0.02 mgMetromac PremisesActive
  • 20 g
0.03 mgMetromac PremisesActive
  • 50 g
0.03 mgMetromac PremisesActive
  • 100 g
0.05 mgMetromac PremisesActive
  • 200 g
0.10 mgMetromac PremisesActive
  • 500 g
0.85 mgMetromac PremisesActive
  • 1 kg
1.2 mgMetromac PremisesActive
  • OIML Masses Class F2 and Lower
  • Using F1 & M1 class W.I. MQS 03 C89 based on OIML R 111:2004
  • 2 kg
10 mgMetromac PremisesActive
  • 5 kg
16 mgMetromac PremisesActive
  • 10 kg
19 mgMetromac PremisesActive
  • 20 kg
0.4 gMetromac PremisesActive
Dimensional Calibration
  • Calipers Dial & Analogue & Digital
  • MQS 03 C 54 based on BS EN ISO 13385-12019 For determining error of indicated size Comparison with gauge blocks or calliper checker
  • Up to 300 mm
26 µmMetromac PremisesActive
  • Up to 600 mm
30 µmMetromac PremisesActive
  • Up to 1000 mm
40 µmMetromac PremisesActive
  • Tape & Scale Calibrator
  • MQS 03 C 113 For determining error of indicated displacement, Comparison with reference measuring tape
  • Up to 1 m
0.4 mmMetromac Premises / Customer PremisesActive
  • Ruler (Engineer or machinst scale)
  • MQS 03 C 112 Measurement of line spacing using length measuring machine equipped with optical magnification unit.
0.82 mmMetromac PremisesActive
  • Measuring Tape
  • MQS 03 C 112 Measurement of line spacing using length measuring machine equipped with optical magnification unit. Stitching is carried out after length of 1 m.
  • Up to 50 m
(0.7 mm +0.12 x L) mm L : mMetromac PremisesActive
  • Dial gauges (Digital & Analogue)
  • MQS 03 C 111 based on JIS B 7503 2017 For determining error of indicated size Comparison with dial gauge calibrator
  • Up to 25 mm (Digital / 0.001 mm)
2.7 µmMetromac PremisesActive
  • Up to 25 mm (Analogue / 0.01 mm)
6.3 µmMetromac PremisesActive
  • Internal two point (bore) micrometer
  • MQS 03 C 110 For determining error of indicated size Comparison with gauge blocks and scale of the universal length measuring machine (ULM).
  • Up to 300 mm
10 µmMetromac PremisesActive
  • External Micrometer (Digital & Analogue)
  • MQS 03 C 109 based on BS EN ISO 3611-2023 For determining error of indicated size Comparison with reference gauge blocks
  • Up to 25 mm
3 µmMetromac PremisesActive
  • 25 to 50 mm
3 µmMetromac PremisesActive
  • 50 to 75 mm
3.5 µmMetromac PremisesActive
  • 75 to 100 mm
4 µmMetromac PremisesActive
  • Dial Gauge
  • Metromac calibration procedure MQS 03 C 164 based on JIS B 7503 2017 For determining error of indicated size Comparison with scale of the universal length measuring machine (ULM).
  • up to 100 mm
6.4 µmMetromac PremisesActive
  • Thickness Gauge (Digital/Analogue)
  • Metromac calibration procedure MQS 03 C 197 For determining error of indicated size Comparison with calibrated gauge blocks
  • up to 12.7 mm
2.5 µmMetromac PremisesActive
  • Thread Plug Gauge
  • Metromac calibration procedure MQS 03 C 162 based on EURAMET Guide -EURAMET cg-10. For determining Simple Pitch Diameter using ULM (three wire method) with nominal pitch: 0.5 mm to 6 mm.
  • 3 mm - 100 mm
3.5 µmMetromac PremisesActive
  • Metromac calibration procedure MQS 03 C 162 based on EURAMET Guide - EURAMET cg-10. For determining Simple Pitch Diameter using ULM (three wire method) with nominal pitch: 4 TPI to 32 TPI.
  • 1/4" to 4"
140 µinMetromac PremisesActive
Volume Calibration
  • Macro Pipette, Micro Pipette, Dispenser
  • MQS 03 C 70, For determining error by Gravimetric Method based on ISO 8655 and uncertainty based on Euramet cg 19.
  • 0.5 µl up to 50 µl
0.04 µlMetromac PremisesActive
  • > 50 µl up to 100 µl
0.11 µlMetromac PremisesActive
  • > 100 µl up to 1 ml
0.39 µlMetromac PremisesActive
  • > 1 ml up to 10 ml
1.20 µlMetromac PremisesActive
  • Beaker
  • METROMAC CALIBRATION PROCEDURE MQS 03 C 121 based on ISO 4787:2021.
  • up to 1000 ml
0.32 mlMetromac premisesActive
  • > 1000 ml to 1500 ml
0.48 mlMetromac premisesActive
  • > 1500 ml to 2000 ml
0.59 mlMetromac premisesActive
  • Burette
  • up to 10 ml
0.031 mlMetromac premisesActive
  • > 10 ml to 50 ml
0.06 mlMetromac premisesActive
  • > 50 ml to 100 ml
0.14 mlMetromac premisesActive
  • Measuring Cylinder
  • up to 200 ml
0.4 mlMetromac premisesActive
  • > 200 ml to 1000 ml
0.58 mlMetromac premisesActive
  • > 1000 ml to 2000 ml
1.2 mlMetromac premisesActive
  • One Mark Flask
  • Upto 1000 ml
0.21 mlMetromac premisesActive
Speed Calibration
  • Speed (Centrifuge / Variable Rotation Speed) eg. : Centrifuges, Mixers, Orbit & Plate shakers, MST Apparatus, Autoclaves
  • SOP - MQS 03 C - 97
  • 6.00 to 999.9 rpm
1.0 rpmMetromac Premises & Customer PremisesActive
  • 1000 up to 6500 rpm
1.7 rpmMetromac Premises & Customer PremisesActive
  • 6501 up to 14000 rpm
1.9 rpmMetromac Premises & Customer PremisesActive
  • Timer (Centrifuge / Variable Rotation Speed) eg. : Centrifuges, Mixers, Orbit & Plate shakers, MST Apparatus, Autoclaves
  • Up to 30 min
0.81 sMetromac Premises & Customer PremisesActive
  • Timer/Stop watch
  • Metromac calibration Procedure:MQS 03 C 144 Comparison with reference Stopwatch
  • upto 8 hr (Resolution : 1 s )
0.81 sMetromac Premises & Customer PremisesActive
  • Metromac calibration Procedure:MQS 03 C 144 Comparison with Universal Frequency Counter
  • upto 8 hr (Resolution : 0.01 s)
0.068 sMetromac PremisesActive
  • upto 8 hr (Resolution : 0.001 s)
0.028 sMetromac PremisesActive
  • TACHOMETER Non-Contact
  • SOP - MQS 03 C-123
  • 6.00 to 99.99 rpm
0.01 rpmMetromac PremisesActive
  • 100.0 to 999.9 rpm
0.1 rpmMetromac PremisesActive
  • 1000 to 99999 rpm
1 rpmMetromac PremisesActive
Electrical-Measuring
  • AC Voltage
  • MetroMac Calibration Procedure MQS 03 C 60 (U=Measured Voltage Value)
  • ( 1.0 mV to 32.999 mV ) 10 Hz to 45 Hz
0.48 x 10-3 U + 3.9 µVMetromac PremisesActive
  • ( 1.0 mV to 32.999 mV ) >45 Hz to 10 kHz
0.11 x 10-3 U + 3.5 µVMetromac PremisesActive
  • ( 1.0 mV to 32.999 mV ) >10 kHz to 20 kHz
0.13 x 10-3 U + 3.5 µVMetromac PremisesActive
  • ( 1.0 mV to 32.999 mV ) >20 kHz to 50 kHz
0.55 x 10-3 U + 3.7 µVMetromac PremisesActive
  • ( 1.0 mV to 32.999 mV ) >50 kHz to 100 kHz
1.9 x 10-3 U +7.1 µVMetromac PremisesActive
  • ( 1.0 mV to 32.999 mV ) >100 kHz to 500 kHz
4.4 x 10-3 U + 30 µVMetromac PremisesActive
  • ( 33 mV to 329.999 mV ) 10 Hz to 45 Hz
0.21 x 10-3 U + 16 µVMetromac PremisesActive
  • ( 33 mV to 329.999 mV ) >45 Hz to 10 kHz
83 x 10-6 U + 5.1 µVMetromac PremisesActive
  • ( 33 mV to 329.999 mV ) >10 kHz to 20 kHz
91 x 10-6 U + 5.1 µVMetromac PremisesActive
  • ( 33 mV to 329.999 mV ) >20 kHz to 50 kHz
0.19 x 10-3 U + 6.8 µVMetromac PremisesActive
  • ( 33 mV to 329.999 mV ) >50 kHz to 100 kHz
0.44 x 10-3 U + 21 µVMetromac PremisesActive
  • ( 33 mV to 329.999 mV ) >100 kHz to 500 kHz
1.1 x 10-3 U + 48 µVMetromac PremisesActive
  • ( 0.33 V to 3.29999 V ) 10 Hz to 45 Hz
0.21 x 10-3U + 0.14 mVMetromac PremisesActive
  • MetroMac Calibration Procedure MQS 03 C 60 (U=Measured Voltage Value)
  • ( 0.33 V to 3.29999 V ) >45 Hz to 10 kHz
84 x 10-6 U + 36 µVMetromac PremisesActive
  • ( 0.33 V to 3.29999 V ) >10 kHz to 20 kHz
0.11 x 10-3 U + 36 µVMetromac PremisesActive
  • MetroMac Calibration Procedure MQS 03 C 60 (U=Measured Voltage Value)
  • ( 0.33 V to 3.29999 V ) >20 kHz to 50 kHz
0.16 x 10-3 U + 30 µVMetromac PremisesActive
  • ( 0.33 V to 3.29999 V ) >50 kHz to 100 kHz
0.38 x 10-3 U + 73 µVMetromac PremisesActive
  • MetroMac Calibration Procedure MQS 03 C 60 (U=Measured Voltage Value)
  • ( 0.33 V to 3.29999 V ) >100 kHz to 500 kHz
1.3 x 10-3 U + 0.33 mVMetromac PremisesActive
  • ( 3.3 V to 32.9999 V ) 10Hz to 45Hz
0.21 x 10-3 U + 1.4 mVMetromac PremisesActive
  • ( 3.3 V to 32.9999 V ) >45 Hz to 10 kHz
85 x 10-6 U + 0.37 mVMetromac PremisesActive
  • ( 3.3 V to 32.9999 V ) >10 kHz to 20 kHz
0.13 x 10-3 U + 0.37 mVMetromac PremisesActive
  • ( 3.3 V to 32.9999 V ) >20 kHz to 50 kHz
0.19 x 10-3 U + 0.43 mVMetromac PremisesActive
  • ( 3.3 V to 32.9999 V ) >50 kHz to 100 kHz
0.50 x 10-3 U + 0.99 mVMetromac PremisesActive
  • ( 33 V to 329.999 V ) 45 Hz to 1 kHz
0.11 x 10-3 U + 1.3 mVMetromac PremisesActive
  • ( 33 V to 329.999 V ) >1 kHz to 10 kHz
0.11 x 10-3 U + 3.8 mVMetromac PremisesActive
  • ( 33 V to 329.999 V ) >10 kHz to 20 kHz
0.14 x 10-3 U + 3.8 mVMetromac PremisesActive
  • ( 33 V to 329.999 V ) >20 kHz to 50 kHz
0.19 x 10-3 U + 5.6 mVMetromac PremisesActive
  • ( 33 V to 329.999 V ) >50 kHz to 100 kHz
1.1 x 10-3 U + 28 mVMetromac PremisesActive
  • ( 330 V to 1000 V ) 45 Hz to 1 kHz
0.16 x 10-3 U + 7.8 mVMetromac PremisesActive
  • ( 330 V to 1000 V ) >1 kHz to 5 kHz
0.14 x 10-3 U + 8.2 mVMetromac PremisesActive
  • ( 330 V to 1000 V ) >5 kHz to 10 kHz
0.17 x 10-3 U + 7.8 mVMetromac PremisesActive
  • DC Voltage
  • MetroMac Calibration Procedure / MQS 03 C 60 (U=Measured Voltage Value)
  • 3 mV to 329.9999 mV
11 x 10-6 U + 1.4 µVMetromac PremisesActive
  • MetroMac Calibration Procedure / MQS 03 C 60 (U=Measured Voltage Value)
  • 0.33 V to 3.299999 V
7.5 x 10-6 U + 2.3 µVMetromac PremisesActive
  • 3.3 V to 32.99999 V
8.8 x 10-6 U + 20 µVMetromac PremisesActive
  • 33 V to 329.9999 V
12 x 10-6 U + 0.2 mVMetromac PremisesActive
  • 330 V to 1000 V
11 x 10-6 U + 1.2 mVMetromac PremisesActive
  • Resistance
  • MetroMac Calibration Procedure MQS 03 C 60 (R=Measured Resistance Value)
  • 0 Ω to 10.9999 Ω
22 x 10-6 R + 5.4 mΩMetromac PremisesActive
  • 11 Ω to 32.9999 Ω
17 x 10-6 R + 8.2 mΩMetromac PremisesActive
  • 33 Ω to 109.9999 Ω
16 x 10-6 R + 8.2 mΩMetromac PremisesActive
  • 110 Ω to 329.9999 Ω
17 x 10-6 R + 11 mΩMetromac PremisesActive
  • 330 Ω to 1.099999 kΩ
17 x 10-6 R + 11 mΩMetromac PremisesActive
  • 1.1 kΩ to 3.299999 kΩ
17 x 10-6 R + 0.11 ΩMetromac PremisesActive
  • 3.3 kΩ to 10.99999 kΩ
17 x 10-6 R + 62 mΩMetromac PremisesActive
  • 11 kΩ to 32.99999 kΩ
17 x 10-6 R + 0.56 ΩMetromac PremisesActive
  • 33 kΩ to 109.9999 kΩ
17 x 10-6 R + 0.61 ΩMetromac PremisesActive
  • 110 kΩ to 329.9999 kΩ
20 x 10-6 R + 6.6 ΩMetromac PremisesActive
  • 330 kΩ to 1.099999 MΩ
19 x 10-6 R + 17 ΩMetromac PremisesActive
  • 1.1 MΩ to 3.299999 MΩ
50 x 10-6 R + 0.085 kΩMetromac PremisesActive
  • 3.3 MΩ to 10.99999 MΩ
75 x 10-6 R + 0.28 kΩMetromac PremisesActive
  • 11 MΩ to 32.99999 MΩ
0.35 x 10-3 R + 1.0 kΩMetromac PremisesActive
  • 33 MΩ to 109.9999 MΩ
0.29 x 10-3 R + 8.9 kΩMetromac PremisesActive
  • 110 MΩ to 329.999 MΩ
3.6 x 10-3 R + 40 kΩMetromac PremisesActive
  • 330 MΩ to 1100 MΩ
8.2 x 10-3 R + 0.62 MΩMetromac PremisesActive
  • DC Current
  • MetroMac Calibration Procedure / MQS 03 C 60 (I=Measured Current Value)
  • 3 µA to 329.999 µA
82 x 10-6 I + 11 nAMetromac PremisesActive
  • 330 µA to 3.29999 mA
55 x 10-6 I + 27 nAMetromac PremisesActive
  • 3.3 mA to 32.9999 mA
55 x 10-6 I + 0.14 µAMetromac PremisesActive
  • 33 mA to 329.999 mA
55 x 10-6 I + 1.4 µAMetromac PremisesActive
  • 330 mA to 2.99999 A
0.11 x 10-3 I + 22 µAMetromac PremisesActive
  • 3 A to 10.9999 A
0.27 x 10-3 I + 0.27 mAMetromac PremisesActive
  • 11 A to 20.5 A
0.55 x 10-3 I +0.41 mAMetromac PremisesActive
  • MetroMac Calibration Procedure MQS 03 C 60 Clamp Meter - Using 50 Turn Coil (I=Measured Current Value)
  • 16.5 A to 149.95 A
7.3 x 10-3 I + 0.14 AMetromac PremisesActive
  • 150 A to 549.5 A
5.7 x 10-3 I + 1.4 AMetromac PremisesActive
  • MetroMac Calibration Procedure MQS 03 C 60 Clamp Meter - Using 50 Turn Coil (I=Measured Current Value)
  • 550 A to 1025 A
5.8 x10-3 I + 2.7 AMetromac PremisesActive
  • (29.00 µA to 329.99 µA) 10 Hz to 20 Hz
1.1 x 10-3 I + 55 nAMetromac PremisesActive
  • (29.00 µA to 329.99 µA) >20 Hz to 45 Hz
0.82 x 10-3 I + 55 nAMetromac PremisesActive
  • (29.00 µA to 329.99 µA) >45 Hz to 1 kHz
0.69 x 10-3 I + 55 nAMetromac PremisesActive
  • AC Current
  • MetroMac Calibration Procedure MQS03 C60 (I=Measured Current Value)
  • (29.00 µA to 329.99 µA) >1 kHz to 5 kHz
1.6 x 10-3 I + 82 nAMetromac PremisesActive
  • (29.00 µA to 329.99 µA) >5 kHz to 10 kHz
4.4 x 10-3 I +0.11 µAMetromac PremisesActive
  • (29.00 µA to 329.99 µA) >10 kHz to 30 kHz
8.7 x 10-3 I +0.22 µAMetromac PremisesActive
  • (0.33 mA to 3.2999 mA) 10 Hz to 20 Hz
1.1 x 10-3 I +0.82 µAMetromac PremisesActive
  • (0.33 mA to 3.2999 mA) >20 Hz to 45 Hz
0.69 x 10-3 I +0.82 µAMetromac PremisesActive
  • (0.33 mA to 3.2999 mA) >45 Hz to 1 kHz
0.55 x 10-3 I +0.82 µAMetromac PremisesActive
  • (0.33 mA to 3.2999 mA) >1 kHz to 5 kHz
1.1 x 10-3 I +0.11 µAMetromac PremisesActive
  • (0.33 mA to 3.2999 mA) >5 kHz to 10 kHz
2.8 x 10-3 I +0.16 µAMetromac PremisesActive
  • (0.33 mA to 3.2999 mA) >10 kHz to 30 kHz
5.5 x 10-3 I +0.33 µAMetromac PremisesActive
  • (3.3 mA to 32.999 mA) 10 Hz to 20 Hz
1.0 x 10-3 I + 1.1 µAMetromac PremisesActive
  • (3.3 mA to 32.999 mA) >20 Hz to 45 Hz
0.50 x 10-3 I + 1.1 µAMetromac PremisesActive
  • (3.3 mA to 32.999 mA) >45 Hz to 1 kHz
0.22 x 10-3 I + 1.1 µAMetromac PremisesActive
  • (3.3 mA to 32.999 mA) >1 kHz to 5 kHz
0.44 x 10-3 I + 1.1 µAMetromac PremisesActive
  • (3.3 mA to 32.999 mA) >5 kHz to 10 kHz
1.1 x 10-3 I + 1.6 µAMetromac PremisesActive
  • (3.3 mA to 32.999 mA) >10 kHz to 30 kHz
2.2 x 10-3 I + 2.2 µAMetromac PremisesActive
  • (33 mA to 329.99 mA) 10 Hz to 20 Hz
1.0 x 10-3 I + 11 µAMetromac PremisesActive
  • (33 mA to 329.99 mA) >20 Hz to 45 Hz
0.50 x10-3 I + 11 µAMetromac PremisesActive
  • (33 mA to 329.99 mA) >45 Hz to 1 kHz
0.22 x 10-3 I + 11 µAMetromac PremisesActive
  • (33 mA to 329.99 mA) >1 kHz to 5 kHz
0.55 x 10-3 I + 27 µAMetromac PremisesActive
  • (33 mA to 329.99 mA) >5 kHz to 10 kHz
1.1 x 10-3 I + 55 µAMetromac PremisesActive
  • MetroMac Calibration Procedure MQS03 C60 (I=Measured Current Value)
  • (33 mA to 329.99 mA) >10 kHz to 30 kHz
2.2 x 10-3 I + 0.11 mAMetromac PremisesActive
  • (0.33 A to 2.99999A) 10 Hz to 45 Hz
0.99 x 10-3 I + 0.55 mAMetromac PremisesActive
  • (0.33 A to 2.99999A) >45 Hz to 1 kHz
0.33 x 10-3 I + 0.57 mAMetromac PremisesActive
  • (0.33 A to 2.99999A) >1 kHz to 5 kHz
3.3 x 10-3 I + 0.55 mAMetromac PremisesActive
  • (0.33 A to 2.99999A) >5 kHz to 10 kHz
14 x 10-3 I + 2.7 mAMetromac PremisesActive
  • (3 A to 10.9999 A) 45 Hz to 100 Hz
0.33 x 10-3 I + 1.1 mAMetromac PremisesActive
  • (3 A to 10.9999 A) >100 Hz to 1 kHz
0.55 x 10-3 I + 1.1 mAMetromac PremisesActive
  • (3 A to 10.9999 A) >1 kHz to 5 kHz
16 x 10-3 I + 1.1 mAMetromac PremisesActive
  • (11 A to 20.5 A) 45 Hz to 100 Hz
0.66 x 10-3 I + 2.7 mAMetromac PremisesActive
  • (11 A to 20.5 A) >100 Hz to 1 kHz
0.82 x 10-3 I +2.7 mAMetromac PremisesActive
  • (11 A to 20.5 A) >1 kHz to 5 kHz
16 x 10-3 I + 2.7 mAMetromac PremisesActive
  • (16.5 A to 149.9995 A) 10 Hz to 100 Hz
14 x10-3 I + 0.21 AMetromac PremisesActive
  • (16.5 A to 149.9995 A) >100 Hz to 440 Hz
15 x 10-3 I + 0.21 AMetromac PremisesActive
  • (150 A to 1025 A) 10 Hz to 100 Hz
8.2 x 10-3 I + 1.9 AMetromac PremisesActive
  • (150 A to 1025 A) >100 Hz to 440 Hz
8.9 x10-3 I + 5 AMetromac PremisesActive
  • Capacitance
  • MetroMac Calibration Procedure MQS 03 C 60 (C=Measured Capacitance Value)
  • (150 A to 1025 A) 0.19 to 0.3999 nF
3.1 x 10-3 C + 5.5 pFMetromac PremisesActive
  • (150 A to 1025 A) 0.4 to 1.0999 nF
3.3 x 10-3 C + 5.8 pFMetromac PremisesActive
  • (150 A to 1025 A) 1.1 to 3.2999 nF
2.9 x 10-3 C + 6.0 pFMetromac PremisesActive
  • (150 A to 1025 A) 3.3 to 10.9999 nF
1.4 x 10-3 C + 11 pFMetromac PremisesActive
  • (150 A to 1025 A) 11 to 32.9999 nF
1.4 x 10-3 C + 57 pFMetromac PremisesActive
  • (150 A to 1025 A) 33 to 109.999 nF
1.2 x 10-3 C + 99 pFMetromac PremisesActive
  • (150 A to 1025 A) 110 to 329.999 nF
1.4 x 10-3 C + 0.22 nFMetromac PremisesActive
  • (150 A to 1025 A) 0.33 to 1.09999 µF
1.2 x 10-3 C + 0.99 nFMetromac PremisesActive
  • (150 A to 1025 A) 1.1 to 3.29999 µF
1.5 x 10-3 C + 2.6 nFMetromac PremisesActive
  • (150 A to 1025 A) 3.3 to 10.9999 µF
1.3 x 10-3 C + 9.9 nFMetromac PremisesActive
  • (150 A to 1025 A) 11 to 32.9999 µF
2.3 x 10-3 C + 29 nFMetromac PremisesActive
  • (150 A to 1025 A) 33 to 109.999 µF
2.4 x 10-3 C + 0.11 µFMetromac PremisesActive
  • (150 A to 1025 A) 110 to 329.999 µF
2.5 x 10-3 C + 0.27 µFMetromac PremisesActive
  • (150 A to 1025 A) 0.33 to 1.09999 mF
2.3 x 10-3 C + 0.99 µFMetromac PremisesActive
  • (150 A to 1025 A) 1.1 to 3.2999 mF
2.5 x 10-3 C + 2.4 µFMetromac PremisesActive
  • (150 A to 1025 A) 3.3 to 10.9999 mF
2.4 x 10-3 C + 10 µFMetromac PremisesActive
  • (150 A to 1025 A) 11 to 32.9999 mF
4.1 x 10-3 C + 22 µFMetromac PremisesActive
  • (150 A to 1025 A) 33 to 110 mF
6.0 x 10-3 C + 90 µFMetromac PremisesActive
  • Frequency
  • MetroMac Calibration Procedure MQS 03 C 60 (f=Measured Frequency Value)
  • 0.01 to 119.99 Hz
0.87 x 10-6 f + 0.08 mHzMetromac PremisesActive
  • 120 to 1199.9 Hz
0.93 x 10-6 f + 0.72 mHzMetromac PremisesActive
  • 1.20 to 11.999 kHz
0.93 x 10-6 f + 7.2 mHzMetromac PremisesActive
  • 12 to 119.99 kHz
0.93 x 10-6 f + 72 mHzMetromac PremisesActive
  • 120 to 1199.9 kHz
0.93 x 10-6 f + 0.72 HzMetromac PremisesActive
  • 1.2 to 2 MHz
1.3 x 10-6 f + 0.30 HzMetromac PremisesActive
  • RTD
  • MetroMac Calibration Procedure MQS 03 C 60
  • -200°C to 0 °C
0.055 °CMetromac PremisesActive
  • > 0°C to 300 °C
0.070 °CMetromac PremisesActive
  • > 300°C to 500 °C
0.10 °CMetromac PremisesActive
  • > 500°C to 800 °C
0.18 °CMetromac PremisesActive
  • Thermocouple
  • (J-Type) -210 °C to -100 °C
0.25 °CMetromac PremisesActive
  • (J-Type) > -100 °C to -30°C
0.18 °CMetromac PremisesActive
  • (J-Type) > -30 °C to 150 °C
0.16 °CMetromac PremisesActive
  • (J-Type) > 150 °C to 760 °C
0.17 °CMetromac PremisesActive
  • (J-Type) > 760 °C to 1200 °C
0.21 °CMetromac PremisesActive
  • (K-Type) -200 °C to -100 °C
0.33 °CMetromac PremisesActive
  • (K-Type) > -100 °C to -25°C
0.20 °CMetromac PremisesActive
  • (K-Type) > -25 °C to 120 °C
0.17 °CMetromac PremisesActive
  • (K-Type) > 120 °C to 1000 °C
0.24 °CMetromac PremisesActive
  • (K-Type) > 1000 °C to 1370 °C
0.34 °CMetromac PremisesActive
  • (J-Type) -200 °C to 0 °C
1.2 °CCustomer PremisesActive
  • (J-Type) > 0°C to 1200 °C
0.85 °CCustomer PremisesActive
  • (K-Type) -200 °C to 0 °C
1.4 °CCustomer PremisesActive
  • (K-Type) > 0 °C to 600 °C
0.94 °CCustomer PremisesActive
  • (K-Type) > 600 °C to 1250 °C
0.96 °CCustomer PremisesActive
Electrical-Source
  • AC Voltage
  • MetroMac Calibration Procedur MQS 03 C 124 (U= Source Voltage Value)
  • (10 mV to 100 mV ) >10 Hz to 20 kHz
0.34 x 10-3 U + 22 µVMetromac PremisesActive
  • (10 mV to 100 mV ) >20 kHz to 50 kHz
0.68 x 10-3 U + 27 µVMetromac PremisesActive
  • (10 mV to 100 mV ) >50 kHz to 100 kHz
3.3 x 10-3 U + 44 µVMetromac PremisesActive
  • (10 mV to 100 mV ) >100 kHz to 300 kHz
22 x 10-3 U + 0.27 mVMetromac PremisesActive
  • (>100 mV to 1 V) >10 Hz to 20 kHz
0.33 x 10-3 U + 0.16 mVMetromac PremisesActive
  • (>100 mV to 1 V) >20 kHz to 50 kHz
0.66 x 10-3 U + 0.27 mVMetromac PremisesActive
  • (>100 mV to 1 V) >50 kHz to 100 kHz
3.3 x 10-3 U + 0.44 mVMetromac PremisesActive
  • (>100 mV to 1 V) >100 kHz to 300 kHz
22 x 10-3 U + 2.7 mVMetromac PremisesActive
  • (> 1 V to 10 V) >10 Hz to 20 kHz
0.29 x 10-3 U + 2.5 mVMetromac PremisesActive
  • (> 1 V to 10 V) >20 kHz to 50 kHz
0.63 x 10-3 U + 3.3 mVMetromac PremisesActive
  • (> 1 V to 10 V) >50 kHz to 100 kHz
3.3 x 10-3 U + 4.7 mVMetromac PremisesActive
  • (> 1 V to 10 V) >100 kHz to 300 kHz
22 x 10-3 U + 27 mVMetromac PremisesActive
  • (>10 V to 100 V) >10 Hz to 20 kHz
0.33 x 10-3 U + 17 mVMetromac PremisesActive
  • (>10 V to 100 V) >20 kHz to 50 kHz
0.66 x 10-3 U + 28 mVMetromac PremisesActive
  • (>10 V to 100 V) >50 kHz to 100 kHz
3.3 x 10-3 U + 44 mVMetromac PremisesActive
  • (>100 V to 1000 V) >10 Hz to 20 kHz
0.34 x 10-3 U + 0.17 VMetromac PremisesActive
  • (>100 V to 1000 V) >20 kHz to 50 kHz
0.66 x 10-3 U +0. 29 VMetromac PremisesActive
  • (>100 V to 1000 V) >50 kHz to 100 kHz
3.2 x 10-3 U + 0.44 VMetromac PremisesActive
  • DC Voltage
  • MetroMac Calibration Procedure MQS 03 C 124 (U= Source Voltage Value)
  • (>100 V to 1000 V) 0 mV to 100 mV
20 x 10-6 U + 2.2 µVMetromac PremisesActive
  • (>100 V to 1000 V) > 100 mV to 1 V
14 x 10-6 U + 4.3 µVMetromac PremisesActive
  • (>100 V to 1000 V) > 1 V to 10 V
13 x 10-6 U + 29 µVMetromac PremisesActive
  • (>100 V to 1000 V) > 10 V to 100 V
21 x 10-6 U + 0.34 mVMetromac PremisesActive
  • (>100 V to 1000 V) > 100 V to 1000 V
23 x 10-6 U + 5.6 mVMetromac PremisesActive
  • Resistance
  • MetroMac Calibration Procedure MQS 03 C 124 (R= Source Resistance Value)
  • 0 Ω to 10 Ω
56 x 10-6 R + 1.6 mΩMetromac PremisesActive
  • > 10 Ω to 100 Ω
55 x 10-6 R + 2.2 mΩMetromac PremisesActive
  • > 100 Ω to 1 kΩ
55 x 10-6 R + 5.7 mΩMetromac PremisesActive
  • > 1 kΩ to10 kΩ
55 x 10-6 R + 55 mΩMetromac PremisesActive
  • > 10 kΩ to100 kΩ
55 x 10-6 R + 0.55 ΩMetromac PremisesActive
  • > 100 kΩ to1 MΩ
56 x 10-6 R + 5.5 ΩMetromac PremisesActive
  • > 1 MΩ to10 MΩ
0.22 x 10-3 R + 56 ΩMetromac PremisesActive
  • > 10 MΩ to100 MΩ
4.4 x 10-3 R + 5.5 kΩMetromac PremisesActive
  • > 100 MΩ to1 GΩ
11 x 10-3 R + 55 kΩMetromac PremisesActive
  • DC Current
  • MetroMac Calibration Procedure MQS 03 C 124 (I= Source Current Value)
  • 10 µA to 100 µA
0.28 x 10-3 I + 14 nAMetromac PremisesActive
  • > 100 µA to 1 mA
0.27 x 10-3 I + 28 nAMetromac PremisesActive
  • > 1 mA to 10 mA
0.27 x 10-3 I + 1.1 µAMetromac PremisesActive
  • > 10 mA to 100 mA
0.28 x 10-3 I + 2.8 µAMetromac PremisesActive
  • > 100 mA to 1 A
0.28 x 10-3 I + 0.11 mAMetromac PremisesActive
  • > 1A to 3 A
0.62 x 10-3 I + 0.31 mAMetromac PremisesActive
  • > 3 A to 10 A
0.85 x 10-3 I +0.57 mAMetromac PremisesActive
  • AC Current
  • MetroMac Calibration Procedure MQS 03 C 124 (I = Source Current Value)
  • (Upto 100 µA) 10 Hz to 5 kHz
0.55 x 10-3 I + 26 nAMetromac PremisesActive
  • (Upto 100 µA) >5 kHz to 10 kHz
1.6 x 10-3 I + 0.14 µAMetromac PremisesActive
  • (Upto 100 µA) 10 Hz to 5 kHz
0.55 x 10-3 I +0.24 µAMetromac PremisesActive
  • (> 100 µA to 1 mA) 10 Hz to 5 kHz
0.55 x 10-3 I +0.24 µAMetromac PremisesActive
  • (> 100 µA to 1 mA) >5 kHz to 10 kHz
1.4 x 10-3 I +1.4 µAMetromac PremisesActive
  • (> 1 mA to 10 mA) 10 Hz to 5 kHz
0.55 x 10-3 I + 2.4 µAMetromac PremisesActive
  • (> 1 mA to 10 mA) >5 kHz to 10 kHz
1.4 x 10-3 I + 14 µAMetromac PremisesActive
  • (> 10 mA to 100 mA) 10 Hz to 5 kHz
0.55 x 10-3 I + 24 µAMetromac PremisesActive
  • (> 10 mA to 100 mA) >5 kHz to 10 kHz
1.2 x 10-3 I + 0.14 µAMetromac PremisesActive
  • (> 100 mA to 1 A) 10 Hz to 5 kHz
0.58 x 10-3 I +0.22 mAMetromac PremisesActive
  • (> 100 mA to 1 A) >5 kHz to 10 kHz
3.6 x 10-3 I + 3.7 mAMetromac PremisesActive
  • (> 1 A to 3 A) 10 Hz to 5 kHz
0.84 x 10-3 I + 1.0 mAMetromac PremisesActive
  • (> 1 A to 3 A) >5 kHz to 10 kHz
3.9 x 10-3 I + 10 mAMetromac PremisesActive
  • (> 3 A to 10 A) 10 Hz to 5 kHz
0.85 x 10-3 I + 4.1 mAMetromac PremisesActive
  • (> 3 A to 10 A) >5 kHz to 10 kHz
2.4 x 10-3 I + 38 mAMetromac PremisesActive
  • Capacitance
  • MetroMac Calibration Procedure MQS 03 C 124 (C= Source Capacitance Value)
  • 0 nF to 1 nF
15 x 10-3 C + 14 pFMetromac PremisesActive
  • > 1 nF to 10 nF
7.3 x 10-3 C + 30 pFMetromac PremisesActive
  • > 10 nF to 100 nF
6.4 x 10-3 C + 0.28 nFMetromac PremisesActive
  • > 100 nF to 1 µF
6.8 x 10-3 C + 2.8 nFMetromac PremisesActive
  • > 1 µF to 10 µF
7.2 x 10-3 C + 27 nFMetromac PremisesActive
  • > 10 µF to 100 µF
7.2 x 10-3 C + 0.27 µFMetromac PremisesActive
  • > 100 µF to 1 mF
7.2 x 10-3 C + 2.8 µFMetromac PremisesActive
  • > 1 mF to 10 mF
12 x 10-3 C + 26 µFMetromac PremisesActive
  • > 10 mF to 40 mF
22 x 10-3 C + 0.16 mFMetromac PremisesActive
  • Frequency
  • MetroMac Calibration Procedure MQS 03 C 124 (f =Source Frequency Value)
  • 5 Hz to10 Hz
0.26 x 10-3 f + 0.21 mHzMetromac PremisesActive
  • >10 Hz to 40 Hz
0.16 x 10-3 f + 41 µHzMetromac PremisesActive
  • >40 Hz to 300 kHz
58 x 10-6 f + 6.5 mHzMetromac PremisesActive
  • >300 kHz to 1000 kHz
56 x 10-6 f + 2.7 HzMetromac PremisesActive
  • RTD Source Pt 100 (-200 to 600)°C
  • MetroMac Calibration Procedure MQS 03 C 124
  • -200 °C to 0 °C
0.10 °CMetromac PremisesActive
  • > 0 °C to 100 °C
0.10 °CMetromac PremisesActive
  • > 100 °C to 600 °C
0.16 °CMetromac PremisesActive
  • Thermocouple - Simulation method
  • (J type) -210 °C to -100 °C
0.24 °CMetromac PremisesActive
  • (J type) > -100 °C to -30 °C
0.16 °CMetromac PremisesActive
  • (J type) > -30 °C to 150 °C
0.15 °CMetromac PremisesActive
  • (J type) > 150 °C to 760 °C
0.16 °CMetromac PremisesActive
  • (J type) > 760 °C to 1200 °C
0.20 °CMetromac PremisesActive
  • (K type) -200 °C to -100 °C
0.30 °CMetromac PremisesActive
  • (K type) > -100 °C to -25 °C
0.18 °CMetromac PremisesActive
  • (K type) > -25 °C to 120 °C
0.16 °CMetromac PremisesActive
  • (K type) > 120 °C to 1000 °C
0.24 °CMetromac PremisesActive
  • (K type) > 1000 °C to 1370 °C
0.34°CMetromac PremisesActive
Electrical
  • Resistance
  • MetroMac Calibration Procedure MQS 03 C 73
  • 10 MΩ to 10 GΩ
0.65 % rdgMetromac PremisesActive
  • Voltage
  • 50 V to 1 kV
0.1 % rdgMetromac PremisesActive
  • >1 kV to 5 kV
2.6 % rdgMetromac PremisesActive
  • Continuity Resistance
  • MetroMac Calibration Procedure MQS 03 C 74
  • 100 mΩ to 10 kΩ
1.2 % rdgMetromac PremisesActive
  • Insulation- Resistance
  • 50 kΩ to 2 GΩ
1.2 % rdgMetromac PremisesActive
  • Insulation- Voltage
  • 50 V to 1000 V
1.2 % rdgMetromac PremisesActive
  • RCD Current
  • 6 m A to 30 m A
0.62 % rdgMetromac PremisesActive
  • >30 m A to 2.0 A
0.60 % rdgMetromac PremisesActive
  • >2.0 A to 2.5 A
1.2 % rdgMetromac PremisesActive
  • RCD Trip Time
  • 10 ms to 2000 ms
0.59 msMetromac PremisesActive
  • Loop Impedance
  • Upto 0.300Ω
0.84 % rdg + 36mΩMetromac PremisesActive
  • > 0.3Ω to 18Ω
0.67 % rdg + 36mΩMetromac PremisesActive
  • >18Ω to 1800Ω
0.59 % rdg + 36mΩMetromac PremisesActive
Temperaure Calibration
  • Air temperature & Relative Humidity Sensors
  • METROMAC calibration procedure MQS 03 C 122
  • -10 °C to 50 °C
0.6 °CMetromac PremisesActive
  • 20 % to 95 % @ 10 °C to 50 °C
1.5 % rhMetromac PremisesActive
  • Liquid in Glass Thermometer
  • METROMAC calibration procedure MQS 03 C 55
  • ­ 40 °C up to 130 °C
0.05 °CMetromac PremisesActive
  • 130 °C up to 270 °C
0.15 °CMetromac PremisesActive
  • Digital Thermometer
  • METROMAC calibration procedure MQS 03 C 59
  • ­ 40 °C up to 130 °C
0.05 °CMetromac PremisesActive
  • 130 °C up to 270 °C
0.10 °CMetromac PremisesActive
  • 270 °C up to 400 °C
0.20 °CMetromac PremisesActive
  • Infrared Thermometer
  • METROMAC calibration procedure MQS 03 C 107
  • -30 °C to -15°C
1.6 °CMetromac PremisesActive
  • ­ 15 °C up to 120 °C
1.2 °CMetromac PremisesActive
  • Temperature Dry Block Calibrator
  • METROMAC calibration procedure MQS 03 C 24
  • ­ 30 °C up to 133 °C
0.20 °CMetromac PremisesActive
  • > 133 °C up to 600 °C
1.5 mK*t/ °CMetromac PremisesActive
  • Liquid Bath (5 points)
  • METROMAC calibration procedure MQS 03 C 76 (5 points)
  • ­ 30 °C up up to 130 °C
0.60 °CCustomer PremisesActive
  • > 130 °C up to 300 °C
1.0 °CCustomer PremisesActive
  • Incubator (5 points)
  • METROMAC calibration procedure MQS 03 C 65
  • 20 °C up to 100 °C
0.45 °CCustomer PremisesActive
  • Refrigerators/ Freezers (9 points)
  • METROMAC calibration procedure MQS 03 C 77
  • -80 °C to -30 °C
0.55 °CCustomer PremisesActive
  • -30 °C to 20 °C
0.45 °CCustomer PremisesActive
  • Ovens (9 points)
  • METROMAC calibration procedure MQS 03 C 40 (9 points)
  • 25 °C up to 100 °C
0.75 °CCustomer PremisesActive
  • > 100 °C up to 200 °C
1.0 °CCustomer PremisesActive
  • > 200 °C up to 250 °C
1.5 °CCustomer PremisesActive
  • Muffle Furnace (1 point)
  • METROMAC calibration procedure MQS 03 C 90
  • 500 °C up to 900 °C
3.0 °CCustomer PremisesActive
  • > 900 °C up to 1100 °C
4.5 °CCustomer PremisesActive
  • Autoclaves
  • METROMAC calibration procedure MQS 03 C 96
  • up to 150°C
0.8 °CCustomer PremisesActive
Pressure Calibration
  • Pneumatic Pressure (Gauge) Analog and digital indicating and electrical output devices
  • Comparison with pressure transducer using W.I. MQS 03 C 61 & MQS 03 C 117 Based on: DKD R 6-1 : 2014 & cg17: 2017.
  • ­ 90 kPa up to 0 kPa
5 Pa + 0.02 % of readingMetromac Premises and Customer PremisesActive
  • 0 kPa up to 100 kPa
10 Pa + 0.02 % of readingMetromac Premises and Customer PremisesActive
  • 0.1 MPa up to 1 MPa
30 Pa + 0.02 % of readingMetromac Premises and Customer PremisesActive
  • 1 MPa up to 10 MPa
300 Pa + 0.02 % of readingMetromac Premises and Customer PremisesActive
  • Hydraulic Pressure (Gauge) Analog and digital indicating and electrical output devices
  • Comparison with DWT using W.I:MQS 03 C 56 & MQS 03 C 117 Based on DKD R 6 - 1: 2014 & cg 17: 2017
  • 0.6 MPa up to 6 Mpa
0.025 % of readingMetromac PremisesActive
  • 6 MPa up to 120 Mpa
0.02 % of readingMetromac PremisesActive
Torque Calibration
  • Hand Torque Tools
  • Direct comparison with reference torque transducer using Work Instruction METROMAC calibration procedure MQS 03 C 115 Based on: ISO 6789-1:2017 and ISO 6789-2:2017
  • 0.04 N•m to 2 N•m Torque Transducer No:124712
0.015Metromac PremisesActive
  • >2 N•m to 1500 N•m
0.01Metromac PremisesActive