Total Weighing And Measuring LLC

Initial Accreditation Date:Jan 09 , 2019

معلومات الاتصال

العنوان

Office 308, Dubai Financial Support Fund - Al Quoz Third., Dubai, United Arab Emirates

صندوق بريد / الرمز البريدي

10239

البريد الإلكتروني

info@tcal.ae qaqc@tcal.ae

الموقع الإلكتروني

www.tacl.ae

رقم الهاتف

+971 054 426 6403

المجال الرئيسي

Calibration Laboratories

ساري منذ:Jan 09 , 2025

Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Balance
  • Weighing Balance
  • TCAL-WI-11 using Standard Weights based on Euramet cg 18
  • 0 up to 500 g
0.86 mgCustomers PremisesActive
Pressure
  • Gauge Pressure: Medium: Pneumatic
  • TCAL-WI-01 by Comparison method using Digital Pressure Gauge as per DKD-R 6-1
  • -90 kPa to 0
5.8 kPaLaboratory and Customer PremisesActive
  • Gauge Pressure: Medium: Hydraulic
  • 0 to 700 kPa
0.50 kPaLaboratory and Customer PremisesActive
  • Gauge Pressure Pneumatic Analog and Digital Pressure Gauges
  • TCAL-WI-01 by Comparison method based on requirement of DKD-R 6-1 (03/2014)
  • 0.7 MPa to 6 MPa
2.9 kPaLaboratory and Customer PremisesActive
  • Gauge Pressure Hydraulic Pressure Transmitters
  • TCAL-WI-02 by Comparison method based on requirement of DKD-R 6-1 (03/2014)
  • 0 to 10 MPa
42 kPaLaboratory and Customer PremisesActive
Electrical
  • DC Voltage
  • Direct Method Using Multi-product Calibrator according to TCAL Calibration Procedures TCAL-WI-28 & 30
  • Up to 200 mV
0.02 mVLaboratoryActive
  • DC Current
  • Up to 200 µA
0.05 µALaboratoryActive
  • AC Voltage
  • Up to 200 mV @ 40 Hz to 10 kHz
0.12 mVLaboratoryActive
  • AC Current
  • Up to 200 µA @ 50 Hz
0.51 µALaboratoryActive
  • Resistance 2 Wire
  • < 0.1 Ω to 1 Ω
7 mΩLaboratoryActive
  • Capacitance
  • < 1 nF to 10 nF
0.05 nFLaboratoryActive
Temperature
  • Direct Reading Thermometers a) Digital Thermometer with PRT Sensor b) Temperature Transmitter with PRT Sensor
  • In-house methods TCALWI-05 & TCAL-WI-06 based on DKD-R-5-1
  • -30℃ to 200℃
0.27℃Laboratory / Customer PremisesActive
  • Direct Reading Thermometers a) Digital Thermometer with thermocouple Sensor, Type K, J, N b) Transmitter with Thermocouple Sensor, type K, J, N c) Bi-Metal & Dial Thermometer
  • In-house methods TCALWI-05 & TCAL-WI-06 based on EURAMET CG No.8
0.3℃Laboratory / Customer PremisesActive
  • Temperature Indicators & Controllers for PRTs
  • Electrical simulation method TCAL-WI-07 based on EURAMET cg11
0.22℃Laboratory / Customer PremisesActive
  • Temperature Indicators & Controllers for Thermocouples Types J, K and N
0.3℃Laboratory / Customer PremisesActive
  • Temperature Chart Recorders Connected to Thermocouples
  • In-house method TCAL-WI-05 based on DKD-R5-1
  • -30℃ to 600℃
1.2℃Laboratory / Customer PremisesActive
  • Climatic Chambers (9 Point Method) for Chiller / Freezer / Refrigerator / Incubator
  • In-house methods TCALWI-10 & TCAL-WI-26 based on DKD-R 5-7
  • -25 ℃ to 50 ℃
0.9 ℃Customer PremisesActive
  • Climatic Chambers (9 Point Method) for Drying Oven / Hot Cabinet
Active
  • Climatic Chambers (Single Point Method) for Chiller / Freezer / Refrigerator / Incubator
Active
  • Climatic Chambers (Single Point Method) for Drying Oven / Hot Cabinet
  • In-house methods TCALWI-10 & TCAL-WI-26 based on DKD-R 5-7
  • > 50℃ to 300℃
1.5 ℃Customer PremisesActive
  • Muffle Furnace (Single Point Method)
  • 400 ℃ to 900 ℃
3.5 ℃Customer PremisesActive
  • Wideband Infrared Thermometers
  • In-house method TCAL-WI-36 based on ASTM E2847-21
  • 50 ℃ to 100 ℃
1.6 oC LaboratoryActive