Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Balance & Scale
  • Top loading weighing scale
Active
Mass
  • Mass
  • ASC/WP/02 Based On STANDARD WEIGHTS AS PER OIML R111-1 F1 from 1 mg to 20 kg
  • 1 mg
0.004 mgArabscale LaboratoryActive
  • 2 mg
0.004 mgArabscale LaboratoryActive
  • 5 mg
0.004 mgArabscale LaboratoryActive
  • 10 mg
0.006 mgArabscale LaboratoryActive
  • 20 mg
0.008 mgArabscale LaboratoryActive
  • 50 mg
0.007 mgArabscale LaboratoryActive
  • 100 mg
0.008 mgArabscale LaboratoryActive
  • 200 mg
0.010 mgArabscale LaboratoryActive
  • 500 mg
0.013 mgArabscale LaboratoryActive
  • 1 g
0.016 mgArabscale LaboratoryActive
  • 2 g
0.019 mgArabscale LaboratoryActive
  • 5 g
0.025 mgArabscale LaboratoryActive
  • 10 g
0.031 mgArabscale LaboratoryActive
  • 20 g
0.041 mgArabscale LaboratoryActive
  • 50 g
0.065 mgArabscale LaboratoryActive
  • 100 g
0.1 mgArabscale LaboratoryActive
  • 200 g
0.26 mgArabscale LaboratoryActive
  • 500 g
0.55 mgArabscale LaboratoryActive
  • 1 kg
0.85 mgArabscale LaboratoryActive
  • 2 kg
3 mgArabscale LaboratoryActive
  • 5 kg
8 mgArabscale LaboratoryActive
  • 10 kg
16 mgArabscale LaboratoryActive
  • 20 kg
30 mgArabscale LaboratoryActive
Volume
  • PIPETTE CALIBRATION
  • ASC/WP/03 Based on ISO 8655-6 (GRAVIMETRIC METHOD)
  • Up to 20 ul
0.087 ulArabscale LaboratoryActive
  • > 20 ul up to 100 ul
0.40 ulArabscale LaboratoryActive
  • > 100 ul up to 250 ul
0.53 ulArabscale LaboratoryActive
  • > 250 ul up to 500 ul
0.78 ulArabscale LaboratoryActive
  • > 500 ul up to 1000 ul
1.4 ulArabscale LaboratoryActive
  • > 1000 ul up to 2000 ul
2.4 ulArabscale LaboratoryActive
  • > 2000 ul up to 5000 ul
6.1 ulArabscale LaboratoryActive
  • > 5000 ul up to 10000 ul
12 ulArabscale LaboratoryActive
Balance
  • Weighing Scale
  • ASC/WP/01 Based On Non-automatic weighing Instruments-EURAMET GUIDE-CG-18
  • 0 & 1 mg up to 21 g
0.05 mgCustomer premisesActive
  • > 21 g Up to 220 g
0.5 mgCustomer premisesActive
  • > 220g up to 6200 g
0.02 gCustomer premisesActive
  • > 6200g up to 10 kg
0.1 gCustomer premisesActive
  • > 10 kg up to 30 kg
5 gCustomer premisesActive
  • > 30 kg up to 60 kg
10 gCustomer premisesActive
  • > 60 kg up to 300 kg
70 gCustomer premisesActive
  • > 300 kg up to 500 kg
0.1 kgCustomer premisesActive
  • > 500 kg up to 1000 kg
0.2 kgCustomer premisesActive
  • > 1000 kg up to 3000 kg
0.5 kgCustomer premisesActive
Temperature
  • Digital thermometers
  • ASC/WP/22
  • -30 °C up to 0 °C
0.12 °CArabscale LaboratoryActive
  • 0 °C up to 50 °C
0.10 °CArabscale LaboratoryActive
  • 50 °C up to 120 °C
0.18 °CArabscale LaboratoryActive
  • 120 °C up to 200 °C
0.30 °CArabscale LaboratoryActive
  • 200 °C up to 400 °C
0.50 °CArabscale LaboratoryActive
  • Liquid-in-glass-thermometer
  • ASC/WP/20
  • -30 °C up to 0 °C
0.18 °CArabscale LaboratoryActive
  • 0 °C up to 50 °C
0.10 °CArabscale LaboratoryActive
  • 50 °C up to 120 °C
0.18 °CArabscale LaboratoryActive
  • Dial type thermometers
  • ASC/WP/21
  • -30 °C up to 120 °C
0.40 °CArabscale LaboratoryActive
  • 120 °C up to 200 °C
0.80 °CArabscale LaboratoryActive
  • 200 °C up to 400 °C
1.5 °CArabscale LaboratoryActive
  • Ovens, Freezers, Refrigerator,Chiller (9 points)
  • ASC/WP/23 based on DKD-R 5-7
  • -30 °C up to 50 °C
0.90 °CCustomer PremisesActive
  • 50 °C up to 250 °C
1.6 °CCustomer PremisesActive
  • Incubator and liquid bath (5 points)
  • ASC/WP/24 & ASC/WP/25 base don DKD-R 5-7
  • -30 °C up to 100 °C
0.70 °CCustomer PremisesActive
  • Autoclaves
  • ASC/WP/26 based on DKD-R 5-7
  • 100 °C up to 140 °C
2.0 °CCustomer PremisesActive
Dimensions
  • Vernier / Dial / Digital Calipers
  • In-House method ASC/WP/30 Based on BS EN ISO 13385-1: 2019 For determining error of indicated size Comparison with gauge blocks / calliper checker
  • 0-300 mm
0.03 mmArabscale LaboratoryActive
  • External Micrometer
  • In-House method ASC/WP/31 Based on BS EN ISO 3611:2023 For determining error of indicated size Comparison with gauge blocks
  • 0-25 mm
2.0 µmArabscale LaboratoryActive
Pressure
  • Pneumatic Pressure Analogue and digital pressure gauges / pressure transducers
  • ASC-WP-06 SOP based on DKD-R-6-1
  • -90 kPa to 0
0.3 kPaArabscale Laboratory/ Customer PremisesActive
  • 0 to 6 MPa
15 kPaArabscale Laboratory/ Customer PremisesActive
  • Hydraulic Pressure Analogue and digital pressure gauges / pressure transducers
  • 0 to 70 MPa
14 kPaArabscale Laboratory/ Customer PremisesActive