Sun Power-Gen FZCO (Dubai Branch)

Initial Accreditation Date:May 31 , 2016

معلومات الاتصال

العنوان

Dubai, United Arab Emirates

صندوق بريد / الرمز البريدي

P.O.Box 2828

البريد الإلكتروني

berlin.mony@sunpowergen.com

الموقع الإلكتروني

www.sunpowergen.com

المجال الرئيسي

Calibration Laboratories

ساري منذ:Oct 31 , 2025

Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Balance & Scale
  • Top loading weighing scale
Active
Pressure
  • Calibration of Digital & Analog Pneumatic Pressure Gauges
  • CTS/SOP/1001 Based on the requirements of DKD R 6-1:2014
  • 0 to 12 MPa
0.036% Not better than 1 mbarLaboratory Permanent LocationActive
  • Calibration of Digital & Analog Hydraulic Pressure Gauges
  • CTS/SOP/1002 Based on the requirements of DKD R 6-1:2014
  • 0 to 120 MPa
0.025% Not better than 10 mbarLaboratory Permanent LocationActive
  • Calibration of Digital & Analog Vacuum Gauges
  • CTS/SOP/1003 Based on the requirements of BS EN 837- 1:1998 and DKD R 6-1:2014
  • 0 to -0.1 MPa
0.10 % of FSLaboratory Permanent LocationActive
Dimensions
  • All types of Caliper Digital / Dial / Vernier
  • Procedure CS1002 based on ISO 13385 For determining error of indicated size Comparison with Caliper Checker and gauge blocks
  • 0 to 300 mm
16 µmLaboratory Permanent Location & Customer LocationActive
  • >300 to 600 mm
20 µmLaboratory Permanent Location & Customer LocationActive
  • Procedure CS1001 based on ISO 13385 For determining error of indicated size Comparison with universal length measuring machina (Trimos)
  • > 600 to1500 mm
20 µm + 1 µm every 100 mmLaboratory Permanent LocationActive
  • External Micrometer Digital / Dial / Vernier
  • Procedure CS1004 based on ISO 3611 For determining error of indicated size Comparison with gauge blocks
  • 0 to 50 mm
1.5 µmLaboratory Permanent Location & Customer LocationActive
  • >50 to 100 mm
2.5 µmLaboratory Permanent Location & Customer LocationActive
  • >100 to 150 mm
4.0 µmLaboratory Permanent Location & Customer LocationActive
  • Procedure CS1003 based on ISO 3611 For determining error of indicated size Comparison with universal length measuring machine (TRIMOS HS1500)
  • >150 to 400 mm
7 µmLaboratory Permanent LocationActive
  • > 400 to 1500 mm
8 µm + 1 µm every 100 mmLaboratory Permanent LocationActive
  • Internal Micrometer (Tubular Inside Micrometer, two point contact) Digital / Dial / Vernier
  • Procedure CS1005 based on BS 959 For determining error of indicated size Comparison with universal length measuring machine (TRIMOS HS1500)
  • 0 to 200 mm
3 µmLaboratory Permanent LocationActive
  • >200 to 400 mm
4 µmLaboratory Permanent LocationActive
  • >400 to 600 mm
5 µmLaboratory Permanent LocationActive
  • >600 to 700 mm
7 µmLaboratory Permanent LocationActive
  • >700 to 800 mm
8 µmLaboratory Permanent LocationActive
  • >800 to 1500mm
9 µm + 1 µm every 100 mmLaboratory Permanent LocationActive
  • Depth Micrometer Digital / Dial / Vernier
  • Procedure CS1007 based on JIS B 7544 For determining error of indicated depth Comparison with universal length measuring machine (TRIMOS HS1500)
  • 0 to 150 mm
4 µmLaboratory Permanent LocationActive
  • >150 to 500 mm
5 µmLaboratory Permanent LocationActive
  • Internal Micrometer (Inside Micrometer, two Line Contact) Digital / Dial / Vernier
  • Procedure CS1006 based on BS 959 For determining error of indicated size Comparison with universal length measuring machine (TRIMOS HS1500)
  • 0 to 200 mm
5 µmLaboratory Permanent LocationActive
  • >200 to 400 mm
6 µmLaboratory Permanent LocationActive
  • >400 to 600 mm
7 µmLaboratory Permanent LocationActive
  • >600 to 800 mm
8 µmLaboratory Permanent LocationActive
  • >800 to 900 mm
9 µmLaboratory Permanent LocationActive
  • >900 to 1500 mm
9 µm + 1 µm every 100 mmLaboratory Permanent LocationActive
  • Depth Gauge (Dial / Digital / Vernier)
  • Procedure CS1008 based on JIS B 7544 For determining error of indicated depth Comparison with universal length measuring machine (TRIMOS HS1500)
  • 0 to 300 mm
7 µmLaboratory Permanent LocationActive
  • >300 to 700 mm
8 µmLaboratory Permanent LocationActive
  • >700 to 1000 mm
10 µmLaboratory Permanent LocationActive
  • Bore Gauge (fixed with dial indicator; Digital / Dial )
  • Procedure CS1009 based on VDI/VDE/DGQ/ 2618 part 13.2 For determining error of indicated size Comparison with universal length measuring machine (TRIMOS HS1500)
  • 0 to 800 mm
7 µmLaboratory Permanent LocationActive
  • Dial Indicator / Dial test Indicator / Lever type dial gauges
  • Procedure CS1010 Based on JIS B 7503 and JIS B 7533 For determining error of indicated displacement, Comparison with dial gauge calibrator
  • 0 to 25 mm
1 µmLaboratory Permanent Location & Customer LocationActive
  • Procedure CS1011 Based on JIS B 7503 and JIS B 7533 For determining error of indicated displacement, Comparison with universal length measuring machine (TRIMOS HS1500)
  • 0 to 100 mm
3 µmLaboratory Permanent LocationActive
  • Steel Ruler
  • Procedure CS1016 Based on JIS B7541 For determining of line spacing using Comparision method with universal length measuring machine (TRIMOS HS1500).
  • 0 to 600 mm
30 µmLaboratory Permanent LocationActive
  • Ring Gauge (Plain Ring Gauge, Cylindrical Setting Standard)
  • Procedure CS1012 Based on ISO 1938 For determining diameter using Comparision method with universal length measuring machine (TRIMOS HS1500) and reference ring gauge
  • 14 to 500 mm
4 µm + 1 µm every 100 mmLaboratory Permanent LocationActive
  • Plug Gauge (Plain Plug Gauge, Setting Standard)
  • Procedure CS1013 Based on ISO 1938 For determining diameter using Comparision method with universal length measuring machine (TRIMOS HS1500) and reference gauge block.
  • 0 to 300 mm
4 µmLaboratory Permanent LocationActive
  • > 300 to 500 mm
5 µmLaboratory Permanent LocationActive
  • > 500 to 700 mm
6 µmLaboratory Permanent LocationActive
  • > 700 to 900 mm
7 µmLaboratory Permanent LocationActive
  • > 900 to 1000 mm
8 µmLaboratory Permanent LocationActive
  • Feeler Gauge
  • Procedure CS1015 Based on JIS B7524 For determining thickness Comparison method using micrometer
  • 0.01 to 5 mm
4 µmLaboratory Permanent LocationActive
  • Height Gauge (Vernier, Digital and Electronic types) Digital / Dial / Vernier
  • Procedure CS1017 Based on ISO 13225 For determining error of indicated size Comparison with Caliper Checker and gauge blocks
  • 0 to 600 mm
11 µmLaboratory Permanent Location & Customer LocationActive
  • Micrometer setting Rods
  • Procedure CS1014 For determining lenth using Comparision method with universal length measuring machine (TRIMOS HS1500).
  • 1 to 300 mm
3 µmLaboratory Permanent LocationActive
  • > 300 to 500 mm
5 µmLaboratory Permanent LocationActive
  • > 600 to 700 mm
6 µmLaboratory Permanent LocationActive
  • > 700 to 900 mm
7 µmLaboratory Permanent LocationActive
  • > 900 to 1100 mm
8 µmLaboratory Permanent LocationActive
  • > 1100 to 1300 mm
9 µmLaboratory Permanent LocationActive
  • >1300 to 1500mm
10 µm + 1µm every 100 mmLaboratory Permanent LocationActive
Electrical
  • Source; AC Current
  • CS 1018 Direct comparision with 5025 multi function calibrator
  • up to 200 µA, 20Hz to 1kHz
0.14 µALaboratory Permanent Location & Customer LocationActive
  • > 200 µA to 2 mA, 20Hz to 1kHz
3 µALaboratory Permanent Location & Customer LocationActive
  • > 2 mA to 20 mA,20Hz to 1kHz
31 µALaboratory Permanent Location & Customer LocationActive
  • > 20 mA to 200 mA,20Hz to 1kHz
0.12 mALaboratory Permanent Location & Customer LocationActive
  • > 200 mA to 2 A,20Hz to 500Hz
2 mALaboratory Permanent Location & Customer LocationActive
  • > 2 A to 22 A,20Hz to 500Hz
18 mALaboratory Permanent Location & Customer LocationActive
  • Source; DC Current
  • up to 200 µA
24 nALaboratory Permanent Location & Customer LocationActive
  • > 200 µA to 2 mA
1 µALaboratory Permanent Location & Customer LocationActive
  • > 2 mA to 20 mA
2 µALaboratory Permanent Location & Customer LocationActive
  • > 20 mA to 200 mA
21 µALaboratory Permanent Location & Customer LocationActive
  • > 200 mA to 2 A
1 mALaboratory Permanent Location & Customer LocationActive
  • > 2 A to 22 A
3 mALaboratory Permanent Location & Customer LocationActive
  • Source; Decade Resistance
  • 1 Ω
6 mΩLaboratory Permanent Location & Customer LocationActive
  • 10 Ω
6 mΩLaboratory Permanent Location & Customer LocationActive
  • 100 Ω
12 mΩLaboratory Permanent Location & Customer LocationActive
  • 1 kΩ
1 ΩLaboratory Permanent Location & Customer LocationActive
  • 10 kΩ
1 ΩLaboratory Permanent Location & Customer LocationActive
  • 100 kΩ
10 ΩLaboratory Permanent Location & Customer LocationActive
  • 1 MΩ
1 kΩLaboratory Permanent Location & Customer LocationActive
  • 10 MΩ
1 kΩLaboratory Permanent Location & Customer LocationActive
  • 100 MΩ
0.10 MΩLaboratory Permanent Location & Customer LocationActive
  • 1 GΩ
10 MΩLaboratory Permanent Location & Customer LocationActive
  • Source; Digital Frequency
  • 1 Hz
6 mHzLaboratory Permanent Location & Customer LocationActive
  • 1 Hz to 1000 Hz
24 mHzLaboratory Permanent Location & Customer LocationActive
  • > 1000 Hz to 1 MHz
23 HzLaboratory Permanent Location & Customer LocationActive
  • > 1 MHz to 10 MHz
1 kHzLaboratory Permanent Location & Customer LocationActive
  • Source; AC Voltage
  • up to 20 mV, 45Hz to 1kHz
8 µVLaboratory Permanent Location & Customer LocationActive
  • > 20mV to 200 mV, 45Hz to 1kHz
71 µVLaboratory Permanent Location & Customer LocationActive
  • > 200 mV to 2 V, 45Hz to 1kHz
1 mVLaboratory Permanent Location & Customer LocationActive
  • > 2 to 20 V, 45Hz to 1kHz
7 mVLaboratory Permanent Location & Customer LocationActive
  • > 20 V to 200 V, 45Hz to 1kHz
71 mVLaboratory Permanent Location & Customer LocationActive
  • > 200 V to 1050 V, 45Hz to 1kHz
0.35 VLaboratory Permanent Location & Customer LocationActive
  • Source; DC Voltage
  • up to 20 mV
7 µVLaboratory Permanent Location & Customer LocationActive
  • > 20mV to 200 mV
18 µVLaboratory Permanent Location & Customer LocationActive
  • > 200 mV to 2 V
0.1 mVLaboratory Permanent Location & Customer LocationActive
  • > 2 to 20 V
1 mVLaboratory Permanent Location & Customer LocationActive
  • > 20 V to 200 V
18 mVLaboratory Permanent Location & Customer LocationActive
  • > 200 V to 1050 V
94 mVLaboratory Permanent Location & Customer LocationActive
  • RTD Simulation PT 100
  • -180 °C to 200 °C
0.24 °CLaboratory Permanent Location & Customer LocationActive
  • 200 °C to 850 °C
0.24 °CLaboratory Permanent Location & Customer LocationActive
  • Thermocouple J – Type
  • -210 °C to -50 °C
0.27 °CLaboratory Permanent Location & Customer LocationActive
  • -50 °C to 1200 °C
0.20 °CLaboratory Permanent Location & Customer LocationActive
  • Thermocouple K – Type
  • -200 °C to -150 °C
0.27 °CLaboratory Permanent Location & Customer LocationActive
  • -150 °C to 1250 °C
0.21 °CLaboratory Permanent Location & Customer LocationActive
  • Thermocouple T – Type
  • -200 °C to -150 °C
0.27 °CLaboratory Permanent Location & Customer LocationActive
  • -150 °C to 0 °C
0.27 °CLaboratory Permanent Location & Customer LocationActive
  • 0 °C to 400 °C
0.20 °CLaboratory Permanent Location & Customer LocationActive
  • Thermocouple R – Type
  • -50 °C to 50 °C
0.92 °CLaboratory Permanent Location & Customer LocationActive
  • 50 °C to 250 °C
0.53 °CLaboratory Permanent Location & Customer LocationActive
  • 250 °C to 1750 °C
0.37 °CLaboratory Permanent Location & Customer LocationActive
  • Thermocouple S – Type
  • -50 °C to 300 °C
0.92 °CLaboratory Permanent Location & Customer LocationActive
  • 300 °C to 1750 °C
0.37 °CLaboratory Permanent Location & Customer LocationActive
  • Thermocouple B – Type
  • 100 °C to 800 °C
1.1 °CLaboratory Permanent Location & Customer LocationActive
  • 800 °C to 1800 °C
1.1 °CLaboratory Permanent Location & Customer LocationActive
  • Thermocouple N – Type
  • -200 °C to -100 °C
0.27 °CLaboratory Permanent Location & Customer LocationActive
  • -100 °C to 500 °C
0.20 °CLaboratory Permanent Location & Customer LocationActive
  • 500 °C to 1300 °C
0.21°CLaboratory Permanent Location & Customer LocationActive
  • Thermocouple E – Type
  • -200 °C to -100 °C
0.27°CLaboratory Permanent Location & Customer LocationActive
  • -100 °C to 0 °C
0.27 °CLaboratory Permanent Location & Customer LocationActive
  • 0 °C to 1000 °C
0.20 °CLaboratory Permanent Location & Customer LocationActive
  • AC Current @ 50 Hz
  • CS 1019 Direct comparision with 5025 multi function calibrator with current coil
  • > 10 A to 22 A > 22 A to 500 A > 500 A to 1100 A
0.18 A 2.9 A 5.8 ALaboratory Permanent Location & Customer LocationActive
  • DC Current
0.18 A 2.9 A 5.8 ALaboratory Permanent Location & Customer LocationActive
  • Measure; Insulation Resistance
  • CS 1020 Direct comparision with 5069 Insulation Resistance Source
  • 100 kΩ , 200 kΩ , 500 kΩ
5.8 kΩLaboratory Permanent Location & Customer LocationActive
  • 1.0 MΩ
16 kΩLaboratory Permanent Location & Customer LocationActive
  • 2.0 MΩ
26 kΩLaboratory Permanent Location & Customer LocationActive
  • 5.0 MΩ
59 kΩLaboratory Permanent Location & Customer LocationActive
  • 10.0 MΩ
0.12 MΩLaboratory Permanent Location & Customer LocationActive
  • > 10 MΩ to 20 MΩ
0.23 MΩLaboratory Permanent Location & Customer LocationActive
  • > 20 MΩ to 30 MΩ
0.35 MΩLaboratory Permanent Location & Customer LocationActive
  • > 30 MΩ to 40 MΩ
0.46 MΩLaboratory Permanent Location & Customer LocationActive
  • > 40 MΩ to 60 MΩ
0.70 MΩLaboratory Permanent Location & Customer LocationActive
  • > 60 MΩ to 80 MΩ
0.93 MΩLaboratory Permanent Location & Customer LocationActive
  • > 80 MΩ to 90 MΩ
1.1 MΩLaboratory Permanent Location & Customer LocationActive
  • > 90 MΩ to 100 MΩ
1.2 MΩLaboratory Permanent Location & Customer LocationActive
  • > 100 MΩ to 400 MΩ
4.7 MΩLaboratory Permanent Location & Customer LocationActive
  • > 400 MΩ to 700 MΩ
8.1 MΩLaboratory Permanent Location & Customer LocationActive
  • > 700 MΩ to 900 MΩ
11 MΩLaboratory Permanent Location & Customer LocationActive
  • > 900 MΩ to 1 GΩ
16 MΩLaboratory Permanent Location & Customer LocationActive
  • > 1 GΩ to 5 GΩ
59 MΩLaboratory Permanent Location & Customer LocationActive
  • > 5 GΩ to 9 GΩ
0.11 GΩLaboratory Permanent Location & Customer LocationActive
  • > 10 GΩ to 50 GΩ
2.9 GΩLaboratory Permanent Location & Customer LocationActive
  • > 50 GΩ to 100 GΩ
5.8 GΩLaboratory Permanent Location & Customer LocationActive
  • Measure; Dc Voltage Direct Method
  • CS 1021 Direct Method Using Time Electronics 5065
  • 0 to 100 mV
21 µVLaboratory Permanent Location & Customer LocationActive
  • > 100 mV to 1 V
0.2 mVLaboratory Permanent Location & Customer LocationActive
  • > 1 to 10 V
2 mVLaboratory Permanent Location & Customer LocationActive
  • > 10 to 100 V
21 mVLaboratory Permanent Location & Customer LocationActive
  • > 100 to 1000 V
0.21 VLaboratory Permanent Location & Customer LocationActive
  • AC Voltage Measure Direct Method
  • 0 to 100 mV, 3 Hz to 5 Hz
1.1 mVLaboratory Permanent Location & Customer LocationActive
  • 0 to 100 mV, 5 Hz to 10 Hz
0.39 mVLaboratory Permanent Location & Customer LocationActive
  • 0 to 100 mV, 10 Hz to 20 kHz
0.12 mVLaboratory Permanent Location & Customer LocationActive
  • > 100 mV to 1V, 3 Hz to 5 Hz
11 mVLaboratory Permanent Location & Customer LocationActive
  • > 100 mV to 1V, 5 Hz to 10 Hz
3.9 mVLaboratory Permanent Location & Customer LocationActive
  • > 100 mV to 1V, 10 Hz to 20 kHz
1 mVLaboratory Permanent Location & Customer LocationActive
  • > 1 V to 10 V, 3 Hz to 5 Hz
0.1 VLaboratory Permanent Location & Customer LocationActive
  • > 1 V to 10 V, 5 Hz to 10 Hz
38 mVLaboratory Permanent Location & Customer LocationActive
  • > 1 V to 10 V, 10 Hz to 20 kHz
12 mVLaboratory Permanent Location & Customer LocationActive
  • > 10 V to 100 V, 3 Hz to 5 Hz
1.0 VLaboratory Permanent Location & Customer LocationActive
  • > 10 V to 100 V, 5 Hz to 10 Hz
0.38 VLaboratory Permanent Location & Customer LocationActive
  • > 10 V to 100 V, 10 Hz to 20 kHz
0.12 VLaboratory Permanent Location & Customer LocationActive
  • > 100 V to 750 V, 3 Hz to 5 Hz
7.7 VLaboratory Permanent Location & Customer LocationActive
  • > 100 V to 750 V, 5 Hz to 10 Hz
2.9 VLaboratory Permanent Location & Customer LocationActive
  • > 100 V to 750 V, 10 Hz to 20 kHz
0.91 VLaboratory Permanent Location & Customer LocationActive
  • Measure; AC Current Direct Method Using Time Electronics 5065
  • up to 1 A , 3 Hz to 5 Hz
10 mALaboratory Permanent Location & Customer LocationActive
  • up to 1 A , 5 Hz to 10 Hz
34 mALaboratory Permanent Location & Customer LocationActive
  • up to 1 A , 10 Hz to 5 kHz
3 mALaboratory Permanent Location & Customer LocationActive
  • > 1 A up to 3 A , 3 Hz to 5 Hz
12 mALaboratory Permanent Location & Customer LocationActive
  • > 1 A up to 3 A , 5 Hz to 10 Hz
4 mALaboratory Permanent Location & Customer LocationActive
  • > 1 A up to 3 A, 10 Hz to 5 kHz
10 mALaboratory Permanent Location & Customer LocationActive
  • Measure; DC Current Direct Method Using Time Electronics 5065
  • up to 10 mA
9 µALaboratory Permanent Location & Customer LocationActive
  • > 10 mA to 100 mA
61 µALaboratory Permanent Location & Customer LocationActive
  • > 100 mA to 1 A
1 mALaboratory Permanent Location & Customer LocationActive
  • > 1 A to 3 A
5 mALaboratory Permanent Location & Customer LocationActive
  • Measure; Resistance Direct Method Using Time Electronics 5065
  • up to 10 Ω
13 mΩLaboratory Permanent Location & Customer LocationActive
  • > 10 Ω to 100 Ω
53 mΩLaboratory Permanent Location & Customer LocationActive
  • > 100 Ω to 1 kΩ
1 ΩLaboratory Permanent Location & Customer LocationActive
  • > 1 kΩ to 10 kΩ
5 ΩLaboratory Permanent Location & Customer LocationActive
  • > 10 kΩ to 100 kΩ
51 ΩLaboratory Permanent Location & Customer LocationActive
  • > 100 kΩ to 1 MΩ
1 kΩLaboratory Permanent Location & Customer LocationActive
  • > 1 MΩ to 10 MΩ
7 kΩLaboratory Permanent Location & Customer LocationActive
  • > 10 MΩ to 100 MΩ
0.93 MΩLaboratory Permanent Location & Customer LocationActive