Jubilant Calibration and Measurement Services LLC

Initial Accreditation Date:Jun 30 , 2015

معلومات الاتصال

العنوان

Shed No.6 , Baghdad street, Al Qusais, Dubai, UAE, Dubai, United Arab Emirates

صندوق بريد / الرمز البريدي

231658

البريد الإلكتروني

tvt@jcmsd.com sales@jcmsd.com

الموقع الإلكتروني

www.jcmsd.com

رقم الهاتف

+971 04 267 1550

رقم الجوال

+971 050 605 1267

المجال الرئيسي

Calibration Laboratories

ساري منذ:Aug 07 , 2024

Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Balance & Scale
  • Top loading weighing scale
Active
Temperature
  • Digital Thermometer (Temperature Indicator with Sensor)
  • In House method as per work Procedure JCMS-WP-06
  • -40 ºC to 0 ºC
0.22 ºCCustomer Premises/ LaboratoryActive
  • Above 0 ºC  to 300 ºC
0.54 ºCCustomer Premises/ LaboratoryActive
  • Above 300 ºC  to 400 ºC
0.54 ºCCustomer Premises/ LaboratoryActive
  • Dial Thermometer (temperature gauge)
  • In House method as per work Procedure JCMS-WP-03(based on BS EN 13190:2001
  • -40 ºC to 0 ºC
0.22 ºCCustomer Premises/ LaboratoryActive
  • Above 0 ºC  to 200 ºC
0.54 ºCCustomer Premises/ LaboratoryActive
  • Above 200 ºC to 400 ºC
0.54 ºCCustomer Premises/ LaboratoryActive
  • Freezer/Chiller/ Refrigerator/Oven/Incubator/ hot cabinet, Autoclave (using 1 or 9 sensors)
  • Comparison method using single and multiple calibrated probes (JCMS-WP-15 & DKD R5-7)
  • -40 ºC to less than 4 ºC
0.4 ºCCustomer Premises/ LaboratoryActive
  • From 4 ºC to 37 ºC
0.65 ºCCustomer Premises/ LaboratoryActive
  • Above 37 ºC to 110 ºC
0.94 ºCCustomer Premises/ LaboratoryActive
  • Above 110 ºC to 350 ºC
1.4 ºCCustomer Premises/ LaboratoryActive
  • Liquid Baths (using 1 or 5 sensors)
  • In house method JCMS-WP-32
  • 0 ºC to 30 ºC
0.4 ºCCustomer Premises/ LaboratoryActive
  • 30 ºC to 70 ºC
0.7 oCCustomer Premises/ LaboratoryActive
  • 70 ºC to 100 ºC
1 oCCustomer Premises/ LaboratoryActive
  • Temperature Indicators / controllers (Type - K) by electrical simulation
  • In house method JCMS WP-13
  • -200 ºC to 1300 ºC
1 ºCCustomer Premises/ LaboratoryActive
  • > 0 ºC to 600 ºC
0.4 °CCustomer Premises/ LaboratoryActive
  • > 600 ºC to 1200 ºC
0.6 °CCustomer Premises/ LaboratoryActive
  • > 1200 ºC to 1300 ºC
0.8 °CCustomer Premises/ LaboratoryActive
  • Infrared Thermometers
  • In house methods (JCMS-WP-79)
  • 50 ºC to 150 ºC
2.6 ºCLaboratoryActive
  • 150 ºC to 250 ºC
3.6 ºCLaboratoryActive
  • 250 ºC to 350 ºC
4.6 ºCLaboratoryActive
  • Temperature Indicators / controllers (Type - J)by electrical simulation
  • In house method JCMS-WP-13)
  • (-200 to 100) °C
0.3 ºCCustomer Premises/ LaboratoryActive
  • (above 100 to 1300) °C
0.4 ºCCustomer Premises/ LaboratoryActive
  • Temperature Indicators / controllers (Type - T)by electrical simulation
  • In house method (JCMS-WP-13)
  • (-200 to -100)°C
0.7 ºCCustomer Premises/ LaboratoryActive
  • (-100 to 400)°C
0.3 ºCCustomer Premises/ LaboratoryActive
  • Temperature Indicators / controllers (Type - R)by electrical simulation
  • (0 to 200)°C
1 ºCCustomer Premises/ LaboratoryActive
  • (Above 200 to 1700)°C
0.7Customer Premises/ LaboratoryActive
  • Temperature Indicators / controllers (Type - S)by electrical simulation
  • (-100 to 200)°C
1 ºCCustomer Premises/ LaboratoryActive
  • (Above 200 to 1700)°C
0.7 ºCCustomer Premises/ LaboratoryActive
  • Temperature Indicators / controllers (Type - N)by electrical simulation
  • In house method(JCMS-WP-13)
  • (-270 to 0)°C
0.4 ºCCustomer Premises/ LaboratoryActive
  • (Above 0 to 1300)°C
0.3 ºCCustomer Premises/ LaboratoryActive
  • Temperature Indicators / controllers (Type - B)by electrical simulation
  • (600 to below 800)°C
0.9 ºCCustomer Premises/ LaboratoryActive
  • > 800 ºC to 1000 ºC
0.8 ºCCustomer Premises/ LaboratoryActive
  • > 1000 ºC to 1800 ºC
0.8 ºCCustomer Premises/ LaboratoryActive
  • Temperature Indicators / controllers (RTD)by electrical simulation
  • In house method (JCMS-WP-13
  • (-190 to 100)°C
0.2 ºCCustomer Premises/ LaboratoryActive
  • > 100 ºC to 790 ºC
0.3 ºCCustomer Premises/ LaboratoryActive
  • Thermohygrometer and "Temperature/Humidity" data logger
  • In house method JCMS-WP-10 based on DKD R-5-8
  • 50 %rH to 90 %rH
4.6 %rhLaboratoryActive
  • 15 °C to 30 °C
0.6 ºCLaboratoryActive
  • Air Temperature Thermometer
  • In house method JCMS-WP-10
0.6 °CLaboratoryActive
  • Liquid in Glass Thermometer
  • In house method JCMS-WP-05 based on OIML R 133
  • "-40 °C to 90 °C
0.4°CLaboratoryActive
  • Dish Washer Temperature
  • In house method JCMS-WP-160
  • 40 °C to 80°C
1.0°CLaboratoryActive
Mass and Balance
  • Electronic Balance
  • Using weights of OIML class: -''E2'' upto 1kg -''F1'' upto 30kg -''M1'' upto 1000kg In accordance to JCMS-WP-01
  • 0 to 8000g
1.0 X 10-5 of UUT FSCustomer PremisesActive
  • > 8 kg to 30 kg
1.4 X 10-5 of UUT FSCustomer PremisesActive
  • > 30 kg to 1000 kg
3.5 X 10-5 of UUT FSCustomer PremisesActive
  • Mass
  • Comparison method using ''E2'', ''F1'' class weight set In accordance to JCMS-WP-55
  • 1g
0.082 mgLaboratoryActive
  • 2g
0.082 mgLaboratoryActive
  • 5g
0.084 mgLaboratoryActive
  • 10g
0.084 mgLaboratoryActive
  • 20g
0.09 mgLaboratoryActive
  • 50g
0.11 mgLaboratoryActive
  • 100g
0.15 mgLaboratoryActive
  • 200g
0.15 mgLaboratoryActive
  • 500g
82 mgLaboratoryActive
  • 1 kg
82 mgLaboratoryActive
  • 2 kg
82 mgLaboratoryActive
  • 5 kg
82 mgLaboratoryActive
  • 10 kg
83 mgLaboratoryActive
  • 20 kg
86 mgLaboratoryActive
Pressure
  • Vacuum Pressure Gauge, Pressure indicating and electrical output devices
  • Comparison method by using Digital pressure gauge with Vacuum pressure calibrator JCMS-WP-02 in accordance to: DKD-R 6-1, Euramet cg.17
  • -85 kPa to 700 kPa -12 psi to 100 psi
0.24 kPa (0.035 psi)Laboratory /Customer PremisesActive
  • Electromechanical & Mechanical Pressure Indicating Devices, Pressure Chart Recorder
  • JCMS-WP-02 in accordance to: DKD-R 6-1, Euramet cg.17
  • 0 MPa to 70 Mpa (0 bar to 700 bar)
21 kPa to 82 kPa (0.021 bar to 0.082 bar)Laboratory /Customer PremisesActive
  • JCMS-WP-02 in accordance to: DKD-R 6-1, Euramet cg.17
  • >70MPa to 250 Mpa (> 700 bar to 2500 bar)
0.021MPa to 0.025 Mpa (0.21 bar to 0.25 bar)Laboratory /Customer PremisesActive
Electrical
  • DC Voltage Calibration of Measuring Instruments
  • Direct Method Using Multi-product Calibrator
  • Up to 200 mV
4.6 µVLaboratoryActive
  • < 200 mV to 2 V
11 µVLaboratoryActive
  • < 2 V to 20 V
0.11 µVLaboratoryActive
  • < 20 V to 200 V
1.2 mVLaboratoryActive
  • < 200 V to 1000 V
6.7 mVLaboratoryActive
  • DC urrent Calibration of Measuring Instruments
  • Direct Method Using Multi product Calibrator
  • Up to 200 µA
0.92 nALaboratoryActive
  • < 200 µA to 2 mA
18 nALaboratoryActive
  • < 2 mA to 20 mA
1.5 µALaboratoryActive
  • < 20 mA to 200 mA
22 µALaboratoryActive
  • DC Current Calibration of Measuring Instruments
  • < 200 mA to 2 A
0.4 mALaboratoryActive
  • < 2 A to 30 A
15 mALaboratoryActive
  • Direct Method Using Multi product Calibrator and Current Coil Station
  • Up to 40 A
0.37 ALaboratoryActive
  • < 40 A to 200 A
1.3 ALaboratoryActive
  • < 200 A to 1500 A
5.9 ALaboratoryActive
  • AC Voltage Calibration of Measuring Instruments
  • Direct Method Using Multi-product Calibrator
  • Up to 200 mV @ 10 Hz
0.52 mVLaboratoryActive
  • (< 200 mV to 2 V) @ 10 Hz
5.0 mVLaboratoryActive
  • (< 2 V to 20 V) @ 10 Hz
50 mVLaboratoryActive
  • Up to 200 V @ 30 Hz
0.16 VLaboratoryActive
  • (< 200 V to 700 V) @ 30 Hz
0.83 VLaboratoryActive
  • Up to 200 mV @ > 40 Hz to 56 Hz
0.12 mVLaboratoryActive
  • (> 200 mV to 2 V) @ > 40 Hz to 56 Hz
1.0 mVLaboratoryActive
  • (> 2 V to 20 V) @ > 40 Hz to 56 Hz
9.1 mVLaboratoryActive
  • (>20 V to 200 V) @ > 40 Hz to 56 Hz
0.10 VLaboratoryActive
  • (> 200 V to 700 V) @ > 40 Hz to 56 Hz
0.41 VLaboratoryActive
  • (> 700 V to 1000 V) @ > 40 Hz to 56 Hz
0.55 VLaboratoryActive
  • Up to 200 mV @ > 200 Hz to 500 kHz
0.77 mVLaboratoryActive
  • (> 200 mV to 2 V) @ > 200 Hz to 500 kHz
15 mVLaboratoryActive
  • (> 2 V to 20 V) @ > 200 Hz to 500 kHz
89 mVLaboratoryActive
  • (> 20 V to 200 V) @ > 200 Hz to 500 kHz
0.25 VLaboratoryActive
  • (> 200 V to 700 V) @ > 200 Hz to 500 kHz
1.7 VLaboratoryActive
  • AC Current Calibration of measuring Instruments
  • Up to 200 µA @ upto 40 Hz
34 nALaboratoryActive
  • (> 200 µA to 2 mA) @ upto 40 Hz
5.2 µALaboratoryActive
  • (> 2 mA to 20 mA) @ upto 40 Hz
52 µALaboratoryActive
  • (> 20 mA to 200 mA) @ upto 40 Hz
0.52 ALaboratoryActive
  • (> 200 mA to 2 A) @ upto 40 Hz
5.2 mALaboratoryActive
  • (> 2 A to 20 A) @ upto 40 Hz
52 mALaboratoryActive
  • Up to 30 A @ upto 40 Hz
23 mALaboratoryActive
  • Up to 200 µA @ > 40 to 56 Hz
34 nALaboratoryActive
  • (> 200 µA to 2 mA) @ > 40 to 56 Hz
1.9 µALaboratoryActive
  • (> 2 mA to 20 mA) @ > 40 to 56 Hz
19 µALaboratoryActive
  • (> 20 mA to 200 mA) @ > 40 to 56 Hz
0.19 mALaboratoryActive
  • (> 200 mA to 2 A) @ > 40 to 56 Hz
2.6 mALaboratoryActive
  • (> 2 A to 20 A) @ > 40 to 56 Hz
23 mALaboratoryActive
  • Up to 30 A @ > 40 to 56 Hz
25 mALaboratoryActive
  • Up to 200 µA @ > 56 to 10 kHz
34 nALaboratoryActive
  • (> 200 µA to 2 mA) @ > 56 to 10 kHz
19 µALaboratoryActive
  • (> 2 mA to 20 mA) @ > 56 to 10 kHz
0.12 mALaboratoryActive
  • (> 20 mA to 200 mA) @ > 56 to 10 kHz
1.5 mALaboratoryActive
  • (> 200 mA to 2 A) @ > 56 to 10 kHz
15 mALaboratoryActive
  • (> 2 A to 20 A) @ > 56 to 10 kHz
74 mALaboratoryActive
  • Resistance 2 Wire Calibration of Measuring Instruments
  • Direct Method Using Multi Product Calibrator
  • > 0.1 Ω to 1 Ω
6.0 mΩLaboratoryActive
  • > 1 Ω to 10 Ω
7.0 mΩLaboratoryActive
  • > 10 Ω to 100 Ω
12 mΩLaboratoryActive
  • > 100 Ω to 1 kΩ
93 ΩLaboratoryActive
  • > 1 kΩ to 10 kΩ
0.93 ΩLaboratoryActive
  • > 10 kΩ to 100 kΩ
9.3 ΩLaboratoryActive
  • > 100 kΩ to 1 MΩ
0.16 kΩLaboratoryActive
  • > 1 MΩ to 10 MΩ
4.5 kΩLaboratoryActive
  • > 10 MΩ to 100 MΩ
0.58 MΩLaboratoryActive
  • > 100 MΩ to 1 GΩ
12 MΩLaboratoryActive
  • Resistance 4 Wire Calibration of Measuring Instruments
  • Direct Method Using Multi product Calibrator
  • 100 mΩ to 1 Ω
5.9 mΩLaboratoryActive
  • < 1 Ω to 10 Ω
6.9 mΩLaboratoryActive
  • < 10 Ω to 100 Ω
12 mΩLaboratoryActive
  • < 100 Ω to 1 kΩ
93 mΩLaboratoryActive
  • < 1 kΩ to 10 kΩ
0.93 ΩLaboratoryActive
  • < 10 kΩ to 100 kΩ
9.3 ΩLaboratoryActive
  • CAPACITANCE Calibration of Measuring Instruments
  • < 10 pF to 90 pF
7.0 pFLaboratoryActive
  • < 90 pF to 100 pF
7.0 pFLaboratoryActive
  • < 100 pF to 900 pF
13 pFLaboratoryActive
  • < 900 pF to 1 nF
3.1 pFLaboratoryActive
  • < 1 nF to 10 nF
29 pFLaboratoryActive
  • < 10 nF to 20 nF
58 pFLaboratoryActive
  • < 20 nF to 50 nF
0.15 nFLaboratoryActive
  • < 50 nF to 100 nF
0.29 nFLaboratoryActive
  • < 100 nF to 1 µF
4.6 nFLaboratoryActive
  • < 1 µF to 10 µF
70 nFLaboratoryActive
  • Frequency Calibration of Measuring Instruments
  • 10 Hz to 100 Hz
2.3 mHzLaboratoryActive
  • < 100 Hz to 1 kHz
23 mHzLaboratoryActive
  • < 1 kHz to 10 kHz
0.23 HzLaboratoryActive
  • < 10 kHz to 20 kHz
0.46 HzLaboratoryActive
  • < 20 kHz to 50 kHz
1.2 HzLaboratoryActive
  • < 50 kHz to 100 kHz
2.3 HzLaboratoryActive
  • < 100 kHz to 1 MHz
23 HzLaboratoryActive
  • < 1 MHz to 10 MHz
230 kHzLaboratoryActive
  • Insulation Resistance Calibration of Measuring Instruments
  • Direct Method Using Multi product Calibrator @ 1000 V
  • < 0.01 MΩ to 0.1 MΩ
5.8 ΩLaboratoryActive
  • < 0.1 MΩ to 0.5 MΩ
5.9 kΩLaboratoryActive
  • < 0.5 MΩ to 1 MΩ
6.2 kΩLaboratoryActive
  • < 1 MΩ to 2 MΩ
7.4 kΩLaboratoryActive
  • < 2 MΩ to 4 MΩ
11 kΩLaboratoryActive
  • < 4 MΩ to 5 MΩ
13 kΩLaboratoryActive
  • < 5 MΩ to 6 MΩ
0.21 MΩLaboratoryActive
  • < 6 MΩ to 10 MΩ
0.35 MΩLaboratoryActive
  • < 10 MΩ to 20 MΩ
0.69 MΩLaboratoryActive
  • < 20 MΩ to 40 MΩ
1.4 MΩLaboratoryActive
  • < 40 MΩ to 50 MΩ
1.7 MΩLaboratoryActive
  • < 50 MΩ to 60 MΩ
2.1 MΩLaboratoryActive
  • < 60 MΩ to 100 MΩ
3.5 MΩLaboratoryActive
  • < 100 MΩ to 200 MΩ
6.9 MΩLaboratoryActive
  • < 200 MΩ to 400 MΩ
14 MΩLaboratoryActive
  • < 400 MΩ to 600 MΩ
21 MΩLaboratoryActive
  • < 600 MΩ to 1000 MΩ
35 MΩLaboratoryActive
  • Direct Method Using Insulation Resistance Box @ 5000V
  • < 100 MΩ to 10 GΩ
1.2 GΩLaboratoryActive
  • Resistance Calibration of Measuring Instruments
  • Direct Method Using Reference Resistances Box
  • < 1 Ω to 10 Ω
58 mΩLaboratoryActive
  • < 10 Ω to 100 Ω
120 mΩLaboratoryActive
  • < 100 Ω to 1 kΩ
1.1 ΩLaboratoryActive
  • < 1 kΩ to 10 kΩ
2.3 ΩLaboratoryActive
  • < 10 kΩ to 100 kΩ
15 ΩLaboratoryActive
  • < 100 kΩ to 1000 kΩ
0.12 kΩLaboratoryActive
  • Continuity Resistance Calibration of Measuring Instruments
  • Direct Method Using Multi product Calibrator & Reference Resistances Box
  • < 1 Ω to 10 Ω
0.58 mΩLaboratoryActive
  • < 10 Ω to 100 Ω
0.29 mΩLaboratoryActive
  • < 100 Ω to 1 kΩ
2.4 ΩLaboratoryActive
  • < 1 kΩ to 10 kΩ
2.3 ΩLaboratoryActive
  • < 10 kΩ to 100 kΩ
15 ΩLaboratoryActive
  • < 100 kΩ to 1000 kΩ
22 kΩLaboratoryActive
  • RPM / Speed (Centrifuge, Mixers, Shakers, Tachometer etc.) Calibration of Measuring Instruments
  • Direct Method Using Multi-product Calibrator & Reference Tachometer
  • Up to 60 rpm
0.004 rpmLaboratory /Customer PremiseActive
  • > 60 rpm to 240 rpm
0.03 rpmLaboratory /Customer PremiseActive
  • > 240 rpm to 20000 rpm
1.4 rpmLaboratory /Customer PremiseActive
  • > 20000 rpm to 30000 rpm
3.0 rpmLaboratory /Customer PremiseActive
  • > 30000 rpm to 55000 rpm
3.3 rpmLaboratory /Customer PremiseActive
  • DC Voltage Calibration of Sourcing Instruments
  • Direct Method Using Document Process Calibrator & Reference Multimeter
  • Up to 100 mV
81 µVLaboratoryActive
  • < 100 mV to 3V
0.75 mVLaboratoryActive
  • < 3 V to 30 V
7.5 mVLaboratoryActive
  • < 30 V to 300 V
0.23 VLaboratoryActive
  • < 300 V to 1000 V
0.2 VLaboratoryActive
  • DC Current Calibration of Sourcing Instruments
  • Up to 1 mA
0.71 µALaboratoryActive
  • > 1 mA to 100 mA
70 µALaboratoryActive
  • > 100 mA to 1 A
0.85 mALaboratoryActive
  • > 1 A to 3 A
3.0 mALaboratoryActive
  • > 3 A to 10 A
19 mALaboratoryActive
  • AC Voltage Calibration of Sourcing Instruments
  • Up to 100 mV @ upto 20 kHz
0.12 mVLaboratoryActive
  • Up to 100 mV @ > 20 kHz to 300 kHz
5.3 mVLaboratoryActive
  • (100 mV to 1 V) @ upto 20 kHz
1.1 mVLaboratoryActive
  • (100 mV to 1 V) > 20 kHz to 300 kHz
52 mVLaboratoryActive
  • (1 V to 10 V) @ upto 20 kHz
12 mVLaboratoryActive
  • (1 V to 10 V) @ > 20 kHz to 300 kHz
0.52 VLaboratoryActive
  • (10 V to 100 V) @ upto 20 kHz
0.12 VLaboratoryActive
  • (10 V to 100 V) @ > 20 kHz to 300 kHz
5.2 VLaboratoryActive
  • (100 V to 750 V) @ upto 20 kHz
0.61 VLaboratoryActive
  • (100 V to 750 V) @ > 20 kHz to 300 kHz
2.5 VLaboratoryActive
  • AC Current Calibration of Sourcing Instruments
  • Up to 10 mA @ 50 Hz
0.03 mALaboratoryActive
  • (> 10 mA to 400 mA) @ 50 Hz
0.86 mALaboratoryActive
  • (> 400 mA to 1 A) @ 50 Hz
4.1 mALaboratoryActive
  • (> 1 A to 10 A) @ 50 Hz
0.03 ALaboratoryActive
  • Up to 10 mA @ > 50 Hz to 10 kHz
0.13 mALaboratoryActive
  • (> 10 mA to 400 mA) @ > 50 Hz to 10 kHz
0.90 mALaboratoryActive
  • (> 400 mA to 1 A) @ > 50 Hz to 10 kHz
0.03 ALaboratoryActive
  • (> 1 A to 10 A) @ > 50 Hz to 10 kHz
0.05 ALaboratoryActive
  • Resistances Calibration of Sourcing Instruments
  • Up to 10 Ω
0.06 ΩLaboratoryActive
  • > 10 Ω to 100 Ω
0.12 ΩLaboratoryActive
  • > 100 Ω to 1000 Ω
1.2 ΩLaboratoryActive
  • > 1 kΩ to 10 kΩ
0.02 kΩLaboratoryActive
  • > 10 kΩ to 100 kΩ
0.01 kΩLaboratoryActive
  • > 100 kΩ to 1 MΩ
0.01 MΩLaboratoryActive
  • >1 MΩ to 10 MΩ
0.12 MΩLaboratoryActive
  • > 10 MΩ to 100 MΩ
0.05 MΩLaboratoryActive
  • Frequency Calibration of Sourcing Instruments
  • Direct Method Using Reference Multimeter /Comparasion Method
  • Up to 10 Hz
0.02 HzLaboratoryActive
  • < 10 Hz to 150 Hz
0.10 HzLaboratoryActive
  • < 150 Hz to 1.2 kHz
1.0 HzLaboratoryActive
  • < 1.2 kHz to 12 kHz
0.01 kHzLaboratoryActive
  • < 12 kHz to 50 kHz
0.02 kHzLaboratoryActive
  • < 50 kHz to 200 kHz
0.02 kHzLaboratoryActive
  • Capacitance Calibration of Sourcing Instruments
  • Direct Method Using Reference Multimeter
  • Up to 10 nF
0.15 nFLaboratoryActive
  • > 10 nF to 100 nF
1.5 nFLaboratoryActive
  • > 100 nF to 1 µF
0.02 µFLaboratoryActive
  • > 1 µF to 10 µF
0.15 µFLaboratoryActive
  • > 10 µF to 100 µF
1.5 µFLaboratoryActive
  • > 100 µF to 10000 µF
180 µFLaboratoryActive
  • Insulation Voltage Calibration of Sourcing Instruments
  • Direct Method Using Multi-product Calibrator
  • Up to 50 V
0.32 VLaboratoryActive
  • < 50V to 100 V
0.60 VLaboratoryActive
  • < 100 V to 250 V
1.5 VLaboratoryActive
  • < 250 V to 500 V
2.9 VLaboratoryActive
  • < 500 V to 1000 V
5.8 VLaboratoryActive
Dimensions
  • All types of Caliper Digital / Dial / Vernier
  • (JCMS-WP-07) based on BS EN ISO 13385
  • Up to 300 mm
0.02 mmLaboratoryActive
  • External Micrometer
  • (JCMS-WP-08) based on BS EN ISO 3611
  • Up to 25 mm
2.0 µmLaboratoryActive
  • Dial gauges (Digital & Analogue)
  • (JCMS-WP-23) based on BS EN ISO 463
4.0 µmLaboratoryActive
  • Height Gauge
  • (JCMS-WP-73) based on ISO 13325
  • Up to 600 mm
0.02 mmLaboratoryActive
  • Dial Thickness Gauge (Digital & Analogue)
  • (JCMS-WP-12) based on ISO 13225
  • Up to 25 mm
4.0 µmLaboratoryActive
  • Depth gauges (Digital & Analogue)
  • (JCMS-WP-29) based on IS-4213
  • Up to 100 mm
0.02 mmLaboratoryActive