Carl Stahl Safety and Security Consultancy

Initial Accreditation Date:Jan 06 , 2019

معلومات الاتصال

العنوان

Dubai, United Arab Emirates

صندوق بريد / الرمز البريدي

26607

البريد الإلكتروني

salman@carlstahl.ae; calibration@carlstahl.ae

الموقع الإلكتروني

http://www.carlstahl.ae

المجال الرئيسي

Calibration Laboratories

ساري منذ:Jan 07 , 2025

Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Pressure
  • Pneumatic Dial Pressure Gauge, Vacuum Gauge, Digital Pressure Gauge, Compound Gauge and Manometer
  • Comparison Method based on DKD R 6-1
  • ­ 90 kPa up to 0 kPa
0.5 kPaLaboratory/ Client PremisesActive
  • 0 up to 200 kPa
1 kPaLaboratory/ Client PremisesActive
  • > 0.2 MPa up to 4 MPa
2 kPaLaboratory/ Client PremisesActive
  • Hydraulic Dial Pressure Gauge and Digital Pressure Gauge
  • 0 up to 200 kPa
1 kPaLaboratory/ Client PremisesActive
  • > 0.2 MPa up to 4 MPa
2 kPaLaboratory/ Client PremisesActive
  • > 4 MPa up to 35 MPa
18 kPaLaboratory/ Client PremisesActive
  • > 35 MPa up to 70 MPa
32 kPaLaboratory/ Client PremisesActive
  • Hydraulic Dial Pressure Gauge, Digital Pressure Gauge, Pressure Transducer, Pressure Transmitter, Pressure Switch, Pressure Calibrator
  • 70 MPa to 280 Mpa
0.18 MpaLaboratory/ Client PremisesActive
Temperature
  • Liquid in Glass Thermometer
  • Comparison Method by using RTD with Indicator CSLB-CI-T1
  • -20 °C to 100 °C
0.25 °CLaboratoryActive
  • > 100 °C to 200 °C
0.30 °CLaboratoryActive
  • Direct Reading Thermometer Digital Thermometer, Temperature Indicator Data Logger with Sensor Transmitter (RTD-Sensors)
  • Comparison Method by using RTD with Indicator CSLB-CI-T6
  • -20 °C to 100 °C
0.17 °CLaboratory & Client PremisesActive
  • > 100 °C to 400 °C
0.25 °CLaboratory & Client PremisesActive
  • Comparison Method by using TC with Indicator CSLB-CI-T6
  • > 400 °C to 650 °C
1.4 °CLaboratory & Client PremisesActive
  • Direct Reading Thermometer, Digital Thermometer, Temperature Indicator Data Logger with Sensor Transmitter (Thermocouple-Sensors)
  • Comparison Method by using RTD with Indicator CSLB-CI-T6
  • -20 °C to 100 °C
0.17 °CLaboratory & Client PremisesActive
  • > 100 °C to 400 °C
0.25 °CLaboratory & Client PremisesActive
  • Comparison Method by using TC with Indicator CSLB-CI-T6
  • > 400 °C to 650 °C
1.4 °CLaboratory & Client PremisesActive
  • Platinum Resistance Thermometers
  • Comparison Method by using RTD with Indicator CSLB-CI-T8 DKD-R 5-1
  • -20 °C to 100 °C
0.17 °CLaboratory & Client PremisesActive
  • > 100 °C to 400 °C
0.25 °CLaboratory & Client PremisesActive
  • Comparison Method by using TC with Indicator CSLB-CI-T8 DKD-R 5-1
  • > 400 °C to 650 °C
1.4 °CLaboratory & Client PremisesActive
  • Base metal thermocouples
  • Comparison Method by using RTD with Indicator CSLB-CI-T8
  • -20 °C to 100 °C
0.17 °CLaboratory & Client PremisesActive
  • > 100 °C to 400 °C
0.25 °CLaboratory & Client PremisesActive
  • Comparison Method by using TC with Indicator CSLB-CI-T8
  • > 400 °C to 650 °C
1.4 °CLaboratory & Client PremisesActive
  • Liquid Temperature Bath
  • Comparison Method at 5 locations by using RTD or Type-K thermocouple with Indicator CSLB-CI-T3
  • -40 °C to 200 °C
0.4 °CLaboratory & Client PremisesActive
  • Dry block temperature Calibrator
  • Comparison Method by using RTD with Indicator CSLB-CI-T4
  • -30 °C to 100 °C
0.17 °CLaboratory & Client PremisesActive
  • > 100 °C to 400 °C
0.25 °CLaboratory & Client PremisesActive
  • Comparison Method by using Type-K thermocouple with Indicator CSLB-CI-T4
  • > 400 °C to 600 °C
1.4 °CLaboratory & Client PremisesActive
  • > 600 °C to 1200 °C
8.0 °CLaboratory & Client PremisesActive
  • Temperature Gauge/Dial Thermometer, Chart Recorder
  • Comparison Method by using RTD with Indicator CSLB-CI-T6
  • -20 °C to 100 °C
0.17 °CLaboratory & Client PremisesActive
  • > 100 °C to 400 °C
0.25 °CLaboratory & Client PremisesActive
  • Comparison Method by using TC with Indicator CSLB-CI-T6
  • > 400 °C to 650 °C
1.4 °CLaboratory & Client PremisesActive
  • Chiller, Freezer, Refrigerator, Incubator, Climate Chamber
  • Comparison Method using Standard Multi Thermocouples with Multichannel Indicators at multi locations CSLB-CI-T5 DKD-R 5-7 Method A or B
  • -40 °C to 100 °C
0.5 °CLaboratory & Client PremisesActive
  • Measuring position in Chiller, Freezer, Refrigerator, Incubator, Climate Chamber
  • Comparison Method at single location using Standard Multi Thermocouples with Multichannel Indicators CSLB-CI-T2 DKD-R 5-7 Method C
0.5 °CClient PremisesActive
  • Oven, Autoclave, Hot Cabinet, Warmer, Hot Box
  • Comparison Method using Standard Multi Thermocouples with Multichannel Indicators at multi locations CSLB-CI-T5 DKD-R 5-7 Method A or B
  • 20 °C to 300 °C
0.5 °CClient PremisesActive
  • Measuring position in Oven, Furnace, Autoclave, Hot Cabinet, Warmer, Hot Box
  • Comparison Method at single location using Standard RTD-Sensor with Indicator CSLB-CI-T2 DKD-R 5-7 Method C
  • 20 °C to 350 °C
0.5 °CClient PremisesActive
  • Measuring position in Furnace
  • Comparison Method at single location using Standard Thermocouple with Indicator CSLB-CI-T2
  • > 350 °C to 600 °C
3.7 °CClient PremisesActive
  • > 600 °C to 1200 °C
8.0 °CClient PremisesActive
  • Dish washers,Glass Washer
  • Comparison method using RTD CSLB-CI-T2
  • 20 °C to 90 °C
0.7 °CClient PremisesActive
  • Relative humidity meters and sensors
  • Comparison Method at (25±5) °C using standard Thermo-Hygrometer CSLB-CI-T7
  • 20% RH to 50% RH
2.6 % RHLaboratoryActive
  • > 50% RH to 90% RH
3.0 % RHLaboratoryActive
Mass
  • OIML Masses Class F2 and lower
  • As Per OIML R111-1
  • 1 mg (M1)
0.08 mgLaboratoryActive
  • 2 mg (M1)
0.08 mgLaboratoryActive
  • 5 mg (M1)
0.08 mgLaboratoryActive
  • 10 mg (M1)
0.08 mgLaboratoryActive
  • 20 mg (M1)
0.08 mgLaboratoryActive
  • 50 mg (M1)
0.09 mgLaboratoryActive
  • 100 mg (M1)
0.09 mgLaboratoryActive
  • 200 mg (M1)
0.09 mgLaboratoryActive
  • 500 mg (M1)
0.09 mgLaboratoryActive
  • 1 g
0.09 mgLaboratoryActive
  • 2 g
0.10 mgLaboratoryActive
  • 5 g
0.11 mgLaboratoryActive
  • 10 g
0.13 mgLaboratoryActive
  • 20 g
0.16 mgLaboratoryActive
  • 50 g
0.20 mgLaboratoryActive
  • 100 g
0.32 mgLaboratoryActive
  • 200 g
0.51 mgLaboratoryActive
  • 500 g (M1)
6.0 mgLaboratoryActive
  • 1 kg (M1)
6.3 mgLaboratoryActive
  • 2 kg (M1)
9.6 mgLaboratoryActive
  • 5 kg (M1)
0.06 gLaboratoryActive
  • 10 kg (M1)
0.12 gLaboratoryActive
  • 20 kg (M1)
0.24 gLaboratoryActive
Balance
  • Top loading direct reading weighing balance
  • As Per Euramet cg 18
  • 0 to 110 g
0.43 mgClient PremisesActive
  • 110 g to 220 g
0.62 mgClient PremisesActive
  • 220 g to 320 g
0.70 mgClient PremisesActive
  • 320 g to 610 g
1.2 mgClient PremisesActive
  • 610 g to 2100 g
3.7 mgClient PremisesActive
  • 2.1 kg to 8.0 kg
16 mgClient PremisesActive
  • 8.0 kg to 20 kg
0.03 gClient PremisesActive
  • 20 kg to 60 kg
12 gClient PremisesActive
  • 60 kg to 150 kg
25 gClient PremisesActive
  • 150 kg to 400kg
63 gClient PremisesActive
  • 400 kg to 700 kg
0.11 kgClient PremisesActive
  • 700 kgto 1000 kg
0.16 kgClient PremisesActive