0 - 0

Thomas Bell Wright International Consultants (Dubai Branch)

Initial Accreditation Date:Aug 13 , 2018

معلومات الاتصال

العنوان

Dubai, United Arab Emirates

صندوق بريد / الرمز البريدي

26385

البريد الإلكتروني

admin@bell-wright.com

الموقع الإلكتروني

www.bell-wright.com

المجال الرئيسي

Testing Laboratories

ساري منذ:Nov 13 , 2024

Type of Activity Test Materials / Products Test Name Test Method Status
Construction Products
  • Performance testing at a building construction site
  • Curtain walling & building envelopes
  • Standard Test Method for Water Penetration - Hose Test
CWCT Section 9Active
  • Buildings
  • Thermal performance of buildings. Determination of air permeability of buildings. Fan pressurization method Measuring air permeability in the envelopes of Dwellings Measuring air permeability in the envelopes of Buildings (Non-Dwellings)
BS EN ISO 9972 ATTMA TSL1 ATTMA TSL2Active
  • Storefronts, Curtain Walls and Slope Glazing Systems
  • Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems (Water Leakage Field Check)
AAMA 501.2Active
  • Performance testing at permanent location
  • Curtain walling & building envelopes
  • Standard Test Method for Water Penetration - Hose Test
CWCT Section 9Active
Construction Materials
  • Airtightness Testing for Building Envelope
  • Building Envelopes
  • Standard Test Method for Determining Air Leakage Rate by Fan Pressurization
ASTM E779Active
  • Acoustic Testing at a building construction site
  • Building Elements
  • Field measurement of sound insulation in buildings and of building elements Part 1: Airborne sound insulation
BS EN ISO 16283-1+A1:2017Active
  • Standard Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
ASTM E336Active
  • Field measurement of sound insulation in buildings and of building elements Part 3: Façade sound insulation
BS EN ISO 16283-3Active
  • Field Measurements of Airborne Sound Attenuation of Building Facades and Facade Elements
ASTM E966Active
  • Measurement and assessment of environmental noise Part 1: Basic quantities and assessment procedures
ISO 1996-1Active