Calibration Laboratories

ساري منذ:Apr 05 , 2024

Measured Quantity / Calibration Instrument Calibration Method Range and Specification Expanded Measurement Location Status
Balance & Scale
  • Top loading weighing scale
Active
Temperature
  • Direct reading thermo-meters with RTD
  • WI-ALBATS-T-03
  • 0 °C up to 50 °C
± 0.25 °CLaboratoryActive
  • 50 °C up to 150 °C
± 0.4 °CLaboratoryActive
  • 150 °C up to 300 °C
± 0.6 °CLaboratoryActive
  • 300 °C up to 600 °C
± 0.8 °CLaboratoryActive
  • Direct reading thermo-meters with TC
  • 0 °C up to 50 °C
± 0.4 °CLaboratoryActive
  • 50 °C up to 150 °C
± 0.6 °CLaboratoryActive
  • 150 °C up to 300 °C
± 0.8 °CLaboratoryActive
  • 300 °C up to 600 °C
± 1.3 °CLaboratoryActive
  • Mechanical dial thermometers
  • 0 °C up to 50 °C
± 0.8 °CLaboratoryActive
  • 50 °C up to 150 °C
± 1.5 °CLaboratoryActive
  • 150 °C up to 300 °C
± 2.5 °CLaboratoryActive
  • 300 °C up to 600 °C
± 5 °CLaboratoryActive
  • Block Calibrator
  • WI-ALBATS-T-09
  • ­20 °C up to 133 °C
0.2 °CLaboratoryActive
  • 133 °C up to 600 °C
1.5 mK * t / °CLaboratoryActive
  • Drying Oven (9 points)
  • WI-ALBATS-T-01
  • 50 °C up to 150 °C
± 1.0 °CCustomer PremisesActive
  • 150 °C up to 200 °C
± 1.5 °CCustomer PremisesActive
  • Incubators (9 points)
  • WI-ALBATS-T-02
  • 25 °C up to 70 °C
± 1.0 °CCustomer PremisesActive
  • Water bath (5-9 points)
  • 5 °C up to 95 °C
± 0.5 °CCustomer PremisesActive
  • Liquid bath (5-9 points)
  • 10 °C up to 200 °C
± 0.5 °CCustomer PremisesActive
  • Refrigerator, Chiller (9 points)
  • 0 °C up to 20 °C
± 1.0 °CCustomer PremisesActive
  • Freezer (9 points)
  • ­18 °C up to 0 °C
± 1.0 °CCustomer PremisesActive
  • Environmental-chamber (9 points)
  • 40 °C up to 200 °C
± 1.0 °CCustomer PremisesActive
  • Hot Cabinet (9 points)
± 1.0 °CCustomer PremisesActive
  • Furnace (1 to 9 points)
  • WI-ALBATS-T-05
  • 300 °C up to 600 °C
± 5 °CCustomer PremisesActive
  • 600 °C up to 1100 °C
± 10 °CCustomer PremisesActive
  • Autoclave (1-9 points)
  • WI-ALBATS-T-08
  • 100 °C up to 140 °C
± 1.0 °CCustomer PremisesActive
  • Infrared Thermometer
  • WI-ALBATS-T-07
  • 20 °C up to 50 °C
± 1.0 °CLaboratoryActive
  • 50 °C up to 100 °C
± 2.0 °CLaboratoryActive
  • Temperature and Humidity meter
  • WI-ALBATS-T-04
  • 18 °C up to 60 °C
± 0.4 °CLaboratoryActive
  • 15 °C up to 80 %RH
± 3 %RHLaboratoryActive
Pressure
  • Pressure Indicating Instrument (Oil-type)
  • WI-ALBATS-P-01
  • 0.1 MPa to 70 Mpa
0.050 %FSLaboratoryActive
  • Pressure Indicating Instrument (Gas-type)
  • WI-ALBATS-P-02
  • 0 to 0.7 Mpa
0.060 %FSLaboratory & Customer PremisesActive
  • Vacuum Meter (Gas-type)
  • -95 kPa to 0
0.050 %FSLaboratory & Customer PremisesActive
Dimensions
  • All types of Caliper Digital / Dial / Vernier
  • Procedure WI-ALBATS-D-01 Based on BS EN ISO 13385-1: 2019 For determining error of indicated size Comparison with gauge blocks
  • 0 mm to 300 mm
0.020 mmLaboratoryActive
  • 300 mm to 450 mm
0.025 mmLaboratoryActive
  • External Micrometer
  • Procedure WI-ALBATS-D-01 Based on JIS 7502 For determining error of indicated size Comparison with gauge blocks
  • 0 mm 100 mm
0.004 mmLaboratoryActive
  • Dial gauges (Digital & Analogue)
  • Procedure WI-ALBATS-D-03 Based on JIS B 7503: 2017; B5/EN/ 150 463-2006 & B5/EN/ ISO 13102:2012 For determining error of indicated displacement, Comparison with dial gauge calibrator/gauge blocks
  • 0 mm to 25 mm
0.004 mmLaboratoryActive
  • LVDT*
  • Procedure WI-ALBATS-D-01 For determining error of indicated displacement Mechanical comparison to calibrated gauge blocks
  • 0 mm to 100 mm
4 + (0.05 x L) μm, L: mmLaboratoryActive
  • Thickness Gauge (Dial & Digital)
  • Procedure WI-ALBATS-D-11 For determining error of indicated size Comparison with calibrated gauge blocks
  • 0 mm to 20 mm
0.003 mmLaboratoryActive
  • 20 mm to 100 mm
0.008 mmLaboratoryActive
  • Feeler Gauges
  • Procedure WI-ALBATS-D-06 Based on JIS B 7524: 2008 & DIN 2275 For determining thickness Comparison method using digital indicator
  • 0.05 mm to 2 mm
0.005 mmLaboratoryActive
Balance
  • Digital Weighing Balance
  • WI-ALBATS-M-01 In accordance to Euramet cg 18v4
  • 0 - 200g
0.22mgCustomers PremisesActive
  • >200-500g
0.77mgCustomers PremisesActive
  • >500- 1kg
0.015gCustomers PremisesActive
  • > 1kg - 3kg
0.13gCustomers PremisesActive
  • > 3 kg - 7kg
0.42gCustomers PremisesActive
  • > 7 kg - 20kg
0.51gCustomers PremisesActive
  • > 20 kg - 60kg
0.8gCustomers PremisesActive
  • > 60 kg - 100kg
3.3gCustomers PremisesActive
  • > 100 kg - 150kg
6.5gCustomers PremisesActive