EHS Central Laboratory

Initial Accreditation Date:Feb 17 , 2004

معلومات الاتصال

العنوان

Dubai, United Arab Emirates

صندوق بريد / الرمز البريدي

2001

البريد الإلكتروني

Ehs.lab@trk.pcfc.ae

الموقع الإلكتروني

www.pcfc.ae

المجال الرئيسي

Testing Laboratories

ساري منذ:Feb 17 , 2025

Type of Activity Test Materials / Products Test Name Test Method Status
Environmental
  • Chemistry
  • Water/ Waste Water
  • Determination of Metals using nitric acid digestion and Inductively Coupled Plasma (ICP):
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Zinc (LOQ = 0.002 mg/L)
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Lead (LOQ = 0.016 mg/L)
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Copper (LOQ = 0.003 mg/L)
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Cadmium (LOQ = 0.001 mg/L)
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Chromium (LOQ = 0.002 mg/L)
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Nickel (LOQ = 0.007 mg/L)
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Iron (LOQ = 0.013 mg/L)
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Manganese (LOQ = 0.002 mg/L)
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Cobalt (LOQ = 0.002 mg/L)
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Silver (LOQ = 0.006 mg/L)
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Aluminium (LOQ = 0.082 mg/L)
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Boron (LOQ = 0.004 mg/L)
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Beryllium (LOQ = 0.006 mg/L)
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Molybdenum (LOQ = 0.011 mg/L)
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Antimony (LOQ = 0.025 mg/L)
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Strontium (LOQ = 0.002 mg/L)
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Vanadium (LOQ = 0.007 mg/L)
APHA 3120 B / APHA 3030 E 24th EditionActive
  • Determination of Total Dissolved Solids dried at 180 °C
APHA 2540 C 24th EditionActive
  • Determination of Total Suspended Solids dried at 103-105 °C
APHA 2540 D 24th EditionActive
  • Determination of Chemical Oxygen Demand (COD) using Open Reflux method
APHA 5220 B 24th EditionActive
  • Determination of Chemical Oxygen Demand (COD) using closed Reflux, Colorimetric method
APHA 5220 D 24th EditionActive
  • Determination of Oil and Grease using Partition – Gravimetric method
APHA 5520 B 24th EditionActive
  • Determination of pH value using Electrometric Method
APHA 4500 H+ B 24th EditionActive
  • Determination of Biological Oxygen Demand (BOD₅)
APHA 5210 B 24th EditionActive
  • Sampling & Storage using manual method Chain of Custody completed together with identification labels
APHA 1060 A, B & C PCFC-TRK-EHS-CL-SOP-07Active
  • Microbiology
  • Water-Potable/ Non-potable water/ Domestic water/ Wastewater/ Recreational water
  • Standard Methods for Examination of Water & Wastewater Heterotrophic Plate Count
APHA 9215 B 24th EditionActive
  • Standard Methods for Examination of Water & Wastewater Total coliform- MF Technique
APHA 9222 B 24th EditionActive
  • Standard Methods for Examination of Water & Wastewater Total coliform and Escherichia coli- Enzyme Substrate Test
APHA 9223 B 24th EditionActive
  • Standard Methods for Examination of Water & Wastewater Fecal coliform- MF technique
APHA 9222 D 24th EditionActive
  • Fecal coliform- Enzyme Substrate Test
PCFC-TRK-EHS-CL-SOP-MIC-06Active
  • Standard Methods for Examination of Water & Wastewater Escherichia coli- MF Partition technique
APHA 9222 H 24th EditionActive
  • Water quality-Detection and Enumeration of Pseudomonas aeruginosa- MFTechnique
BS EN ISO 16266Active
  • Detection and Enumeration of Pseudomonas aeruginosa- IDEXX method
PCFC-TRK-EHS-CL-SOP-MIC-07Active
  • Water quality — Detection and enumeration of intestinal enterococci — Part 2: Membrane filtration method
ISO 7899-2Active
  • Water Quality: Detection and Enumeration of Legionella
ISO 11731 Matrix A procedure 5, 7, 8, 9 and 10 Matrix B procedures 8, 9 and 10Active
  • Sample collection
APHA 9060 A, APHA 9213 B 24th EditionActive
  • Sampling
  • Water
  • Sampling for Legionella bacteria in water systems. Code of practice
BS 7592 Section 2 Routine SamplingActive
Air Quality
  • Environmental Monitoring
  • Stack Emission (Sampling and Monitoring)
  • Determination of Carbon Monoxide (CO) (Measurement Range 0 - 500 PPM)
PCFC-TRK-EHS-CL-SOP-ENV-04 USEPA EMC CTM - 030 &34; US EPA-Method 10:2017Active
  • Determination of Sulphur Dioxide (SO₂) (Measurement Range 0 - 100 PPM)
PCFC-TRK-EHS-CL-SOP-ENV-04 USEPA EMC CTM - 6C US EPA-Method 6C : 2017Active
  • Determination of Nitrogen Oxides (NOx) (Calculated from NO and NO2) Measurement Range: NO: 0 - 5000 PPM NO2 : 0 - 1000 PPM
PCFC-TRK-EHS-CL-SOP-ENV-04 USEPA EMC CTM - 030 & 34 US EPA-Method 7E:2018Active
  • Determination of Oxygen (O₂) (Measurement Range 0 - 25%)
PCFC-TRK-EHS-CL-SOP-ENV-04 US EPA-Method 3C: 2017Active
  • Determination of Carbon Dioxide (CO₂) (Measurement Range 0 - 40%)
PCFC-TRK-EHS-CL-SOP-ENV-04 USEPA EMC CTM - 030; US EPA-Method 3C:2017Active
  • Determination of Hydrocarbon (Measurement Range 0 - 2000 PPM)
PCFC-TRK-EHS-CL-SOP-ENV-04 US EPA-Method 3C:2017Active